Technical Overview

The SICK OD1-B100H50U25 is a laser displacement sensor with a 50–150 mm measuring range, a stainless steel housing and a PPSU window. Its 655 nm Class 1 red laser forms a typical 700 × 600 µm spot at 100 mm. One teachable 0–10 V analog output provides 13.4-bit resolution into a load above 10 kΩ, alongside one selectable PNP/NPN digital output. Averaging from 1 to 512, automatic or manual sensitivity and taught distance/window conditions adapt evaluation to the task. The specified 20 µm repeatability requires averaging 512 and constant ambient conditions, while ±100 µm linearity applies to 90% remission white ceramic. A four-digit display, four buttons and 30 cm lead with an M12 five-pin plug support setup.

50–150 mm Class 1 laser displacement sensor with taught 0–10 V output, selectable PNP/NPN digital output, stainless housing and M12 five-pin lead.

Key Features

  • 50–150 mm laser displacement measuring range
  • 655 nm Class 1 red laser; maximum Class 1 output 390 µW
  • Typical 700 × 600 µm spot at 100 mm
  • 20 µm repeatability at averaging 512 and constant ambient conditions
  • ±100 µm linearity on 90% remission white ceramic
  • One 0–10 V analog output, load >10 kΩ; 13.4-bit resolution
  • One selectable PNP/NPN output; teachable analog/digital settings and digital inversion
  • Averaging 1–512; automatic/manual sensitivity; distance, window and intervening-object modes
  • Multifunction input: laser-off, external teach, trigger or disabled
  • Stainless steel housing; PPSU window; IP67; four-digit display and M12 five-pin lead

Teach the analog distance span and switching conditions to provide measured surface distance and local decision signals to external inspection control.

Technical Specification Matrix

ParameterValue
Functional principleLaser displacement measurement
Measuring range50–150 mm
Repeatability20 µm at averaging 512 and constant ambient conditions
Linearity±100 µm on 90% remission white ceramic
Response time≥2 ms with fixed sensitivity and averaging 1; automatic sensitivity: 2–7.5 ms at 500 µs measuring rate, 4–15 ms at 1,000 µs measuring rate
Measuring frequency≤2 kHz
Output time≥0.5 ms
Light sourceVisible red laser; 655 nm
Laser classClass 1; maximum output 390 µW; IEC 60825-1:2014 / EN 60825-1:2014
Typical light spot size700 × 600 µm at 100 mm; 900 × 800 µm at 50 mm; 550 × 500 µm at 150 mm
Averaging1–512x
Sensitivity adjustmentAutomatic or manual
Analog outputOne teachable 0–10 V voltage output; load >10,000 Ω; 13.4-bit resolution
Digital outputOne selectable PNP/NPN output; teachable and invertible
Switching modesWindow (Wnd); distance to object (DtO); object between sensor and background (ObSB)
Multifunction inputOne MF: laser-off, trigger, external teach-in or deactivated
Power supply12 V DC −5% to 24 V DC +10%
Warm-up time≤5 min
DisplayFour-digit seven-segment display plus four status LEDs
ControlsFour buttons
IndicationDigital output, zero offset, teach mode and laser status; measured-value minus indicator
Connection30 cm cable with M12 five-pin male connector
Pin assignment1 BN=L+; 2 WH=QA; 3 BU=0 V; 4 BK=digital output; 5 GY=MF
Housing materialStainless steel
Window materialPPSU plastic
MountingTwo M3 mounting positions
IP ratingIP67
Protection classIII
Operating temperature−10 to +50 °C
Storage temperature−20 to +60 °C
Relative humidity35–95%; non-condensing
Temperature drift±0.08% FS/K; FS is the sensor measuring range
Typical ambient light immunityArtificial light ≤3,000 lx; sunlight ≤10,000 lx
Vibration resistance10–55 Hz, 1.5 mm amplitude; X/Y/Z axes, 2 h each
Shock resistance50 G; X/Y/Z axes, three times each
Paint-wetting conditionNot free of paint-wetting impairment substances
MTTFD101 years
DCavg0%
Physical Weight (kg)0.07

Industrial Applications

1. Checking component height in a presentation fixture

An inspection fixture can hold a component within the 50–150 mm measuring range and send the taught 0–10 V signal to external height-evaluation logic. The controller references distance to the fixture geometry and compares the result with its configured limits. Precision assessment applies the actual surface response, the white-ceramic linearity condition and the averaging-512 constant-ambient requirement for the repeatability figure.

Problem Solved

A surface-distance value referenced to the fixture gives external inspection a height-comparison basis, helping identify a presented component that differs from the configured dimensional limit.

Fixture height 0–10 V Averaging conditions

2. Monitoring the standoff of a supported moving web

A web-handling machine can aim the laser at a supported material surface and read the analog distance as a standoff reference. External control compares that value with a taught installation setpoint. Commissioning selects sensitivity and averaging for the actual surface, and schedules the control loop from the corresponding response-time and output-time conditions rather than assuming the fastest settings provide the highest repeatability.

Problem Solved

Continuous distance feedback gives external web-position control a surface-standoff reference, helping identify vertical movement relative to the installed sensor during supported material transport.

Web standoff Analog feedback Mode-dependent response

3. Checking seating within a taught distance window

An assembly station can present a component at a known pose and configure a digital switching window around the expected surface distance. The selectable PNP/NPN output sends the resulting condition to external assembly sequencing. A trigger input can coordinate observation with the station’s presentation cycle, while the local display and teach controls support setup of the installed component and reference geometry.

Problem Solved

A taught distance-window state gives external sequencing a seating-condition reference, helping distinguish the expected component surface position from a presentation outside the configured window.

Seating window PNP/NPN selection External trigger