| Product type | Multiturn motor feedback system; standard non-safety product |
| Sine/cosine periods per revolution | 1,024 |
| Absolute revolutions | 4,096 |
| Total absolute steps | 134,217,728 |
| Measuring step | 0.3 arcseconds when sine/cosine signals are interpolated with, for example, 12 bits |
| Integral non-linearity | Typical ±45 arcseconds; error limits for evaluation of a sine/cosine period |
| Differential non-linearity | ±7 arcseconds |
| System accuracy | ±52 arcseconds |
| Absolute-position speed limit | ≤6,000 rpm, up to which absolute position can be reliably produced |
| Available memory | 1,792 bytes |
| Communication interface | HIPERFACE |
| Absolute code | Binary; increasing for clockwise shaft rotation viewed in direction A of the manufacturer drawing |
| Connection | Radial M23 twelve-pin male connector |
| Power supply | 7–12 V DC; recommended 8 V DC |
| Current consumption | 80 mA without load |
| Sine/cosine output frequency | ≤200 kHz |
| Process signal amplitude | SIN/COS peak-to-peak: 0.9–1.1 V |
| Reference signal offset | REFSIN/REFCOS: 2.2–2.8 V |
| Shaft | Solid shaft, Ø6 mm |
| Mounting arrangement | Servo flange; stator coupling |
| Rotor moment of inertia | 25 gcm² |
| Mechanical operating speed | ≤6,000 rpm |
| Angular acceleration | ≤200,000 rad/s² |
| Operating torque | 1 Ncm |
| Start-up torque | +1.5 Ncm |
| Permissible shaft loading | 40 N radial; 20 N axial |
| Bearing lifetime | 3.6 × 10⁹ revolutions |
| Operating temperature | −30 to +85 °C |
| Storage temperature | −30 to +90 °C without package |
| Relative humidity | 90%; condensation not permitted |
| Shock resistance | 100 g, 10 ms, EN 60068-2-27 |
| Vibration resistance | 20 g, 10–2,000 Hz, EN 60068-2-6 |
| IP rating | IP65 with mating plug inserted, IEC 60529 |
| EMC | EN 61000-6-2 and EN 61000-6-3, with conductive housing connected through cable screen to controller central earth and supply GND grounded at the same point; other shielding concepts require application testing |
| MTTFD | 235 years, EN ISO 13849; nominal component load, average +60 °C, 8,760 h/year and all electronic failures considered hazardous; no safety-component rating |
| Default model settings | SRM model ID 27h; address 40h; Mode_485 E4h; codes 0–3: 55h; counter 0 |
| Position and temperature commands | 42h reads 27-bit SRM position; 43h sets position; 44h reads temperature, channel F0h 48h |
| Counter commands | 46h read; 47h increment; 49h delete |
| Memory commands | 4Ah read data; 4Bh store data; 4Ch determine data-field status; 4Dh create data field; 4Eh determine available memory; 4Fh change access code |
| Device commands | 50h read encoder status; 52h read type label (SRM=27h); 53h reset; 55h allocate address; 56h read serial number/program version; 57h configure serial interface |
| Protected command parameter | 43h, 49h, 55h and 57h include Code 0 for protection against accidental overwriting; factory Code 0 is 55h |
| Encoder-status diagnostics | 00h: no detected fault; initialization, protocol, data-field and position errors; analog-signal monitoring, critical transmitter current/P2RAM, critical temperature and counter overflow; SRM includes multiturn position errors 21h/22h/23h |