SICK 1037104 SRM50-HXA0-K22 HIPERFACE Motor Feedback System

USD 1,414.92

SRM50-HXA0-K22 combines 1,024 sine/cosine periods, 4,096 absolute revolutions, HIPERFACE communication, a 6 mm solid shaft and radial M23 connection.

SKU SICK-1037104 Category
SICK Motor Feedback Systems

SICK SRM50-HXA0-K22 HIPERFACE Motor Feedback System

BrandSICK
Model IdentifierSRM50-HXA0-K22
Official Part Number1037104

Technical Overview

The SICK SRM50-HXA0-K22 is a multiturn motor feedback system combining 1,024 sine/cosine periods per revolution with HIPERFACE communication. Its absolute position spans 4,096 revolutions and 134,217,728 total steps, with system accuracy of ±52 arcseconds. Absolute position can be reliably formed up to 6,000 rpm, and the sine/cosine output frequency is limited to 200 kHz. The unit has a 6 mm solid shaft, a servo-flange/stator-coupling arrangement and a radial twelve-pin M23 male connector. Supply is 7–12 V DC, with 8 V recommended. Data-memory, temperature and encoder-status commands support integration with an external drive. IP65 applies with the mating plug inserted; this model is a standard, non-safety product.

Multiturn HIPERFACE feedback system with 1,024 sine/cosine periods, 4,096 absolute revolutions, ±52 arcsecond system accuracy and a 6 mm solid shaft.

Key Features

  • 1,024 sine/cosine periods per revolution
  • 4,096 absolute revolutions; 134,217,728 total steps
  • HIPERFACE interface; binary absolute position; SRM read-position command returns 27 bits
  • System accuracy ±52 arcseconds; typical integral non-linearity ±45 arcseconds
  • Absolute position formation and mechanical operation up to 6,000 rpm
  • 7–12 V DC; recommended 8 V; 80 mA without load
  • Radial M23 twelve-pin male connector
  • 6 mm solid shaft; servo flange and stator coupling
  • 1,792-byte available memory; data, temperature and encoder-status commands
  • IP65 with mating plug inserted; −30 to +85 °C operation; standard non-safety model

Combine sine/cosine motor feedback with a multiturn absolute reference and HIPERFACE memory and diagnostic access through one radial M23 connection.

Technical Specification Matrix

ParameterValue
Product typeMultiturn motor feedback system; standard non-safety product
Sine/cosine periods per revolution1,024
Absolute revolutions4,096
Total absolute steps134,217,728
Measuring step0.3 arcseconds when sine/cosine signals are interpolated with, for example, 12 bits
Integral non-linearityTypical ±45 arcseconds; error limits for evaluation of a sine/cosine period
Differential non-linearity±7 arcseconds
System accuracy±52 arcseconds
Absolute-position speed limit≤6,000 rpm, up to which absolute position can be reliably produced
Available memory1,792 bytes
Communication interfaceHIPERFACE
Absolute codeBinary; increasing for clockwise shaft rotation viewed in direction A of the manufacturer drawing
ConnectionRadial M23 twelve-pin male connector
Power supply7–12 V DC; recommended 8 V DC
Current consumption80 mA without load
Sine/cosine output frequency≤200 kHz
Process signal amplitudeSIN/COS peak-to-peak: 0.9–1.1 V
Reference signal offsetREFSIN/REFCOS: 2.2–2.8 V
ShaftSolid shaft, Ø6 mm
Mounting arrangementServo flange; stator coupling
Rotor moment of inertia25 gcm²
Mechanical operating speed≤6,000 rpm
Angular acceleration≤200,000 rad/s²
Operating torque1 Ncm
Start-up torque+1.5 Ncm
Permissible shaft loading40 N radial; 20 N axial
Bearing lifetime3.6 × 10⁹ revolutions
Operating temperature−30 to +85 °C
Storage temperature−30 to +90 °C without package
Relative humidity90%; condensation not permitted
Shock resistance100 g, 10 ms, EN 60068-2-27
Vibration resistance20 g, 10–2,000 Hz, EN 60068-2-6
IP ratingIP65 with mating plug inserted, IEC 60529
EMCEN 61000-6-2 and EN 61000-6-3, with conductive housing connected through cable screen to controller central earth and supply GND grounded at the same point; other shielding concepts require application testing
MTTFD235 years, EN ISO 13849; nominal component load, average +60 °C, 8,760 h/year and all electronic failures considered hazardous; no safety-component rating
Default model settingsSRM model ID 27h; address 40h; Mode_485 E4h; codes 0–3: 55h; counter 0
Position and temperature commands42h reads 27-bit SRM position; 43h sets position; 44h reads temperature, channel F0h 48h
Counter commands46h read; 47h increment; 49h delete
Memory commands4Ah read data; 4Bh store data; 4Ch determine data-field status; 4Dh create data field; 4Eh determine available memory; 4Fh change access code
Device commands50h read encoder status; 52h read type label (SRM=27h); 53h reset; 55h allocate address; 56h read serial number/program version; 57h configure serial interface
Protected command parameter43h, 49h, 55h and 57h include Code 0 for protection against accidental overwriting; factory Code 0 is 55h
Encoder-status diagnostics00h: no detected fault; initialization, protocol, data-field and position errors; analog-signal monitoring, critical transmitter current/P2RAM, critical temperature and counter overflow; SRM includes multiturn position errors 21h/22h/23h

Industrial Applications

1. Providing feedback to a motor position loop

An external motor drive can evaluate the 1,024 sine/cosine periods per revolution as the shaft turns and use the feedback in its position loop. HIPERFACE absolute information supplies the associated angular reference. Drive design accounts for the ±52 arcsecond system accuracy, the 200 kHz signal-frequency limit and the 6,000 rpm absolute-position formation limit rather than treating interpolation step size as accuracy.

Problem Solved

Sine/cosine feedback and an absolute reference give the external drive complementary motion information, helping it relate measured shaft movement to the commanded motor position.

Motor position loop Sine/cosine feedback HIPERFACE

2. Reading a multi-revolution actuator travel reference

A rotary-driven actuator can couple its motor shaft to this feedback system so an external controller reads an absolute reference across multiple revolutions. The SRM read-position command returns 27 bits over 4,096 absolute revolutions. Machine software converts that shaft reference using the actual transmission ratio and travel geometry, with the documented absolute-position speed limit applied during motion.

Problem Solved

The multiturn reference distinguishes repeated single-turn angles over the available revolution span, helping external actuator control relate shaft position to travel within that span.

Multiturn travel 4,096 revolutions 27-bit readout

3. Collecting feedback-device condition information

A drive maintenance function can query encoder status and the temperature channel through HIPERFACE while keeping that information separate from motion feedback. The device reports defined initialization, protocol, data and position conditions, including multiturn errors for the SRM model. External maintenance software logs these observations and associates them with the affected axis and its operating history.

Problem Solved

Digital temperature and status access gives maintenance software device-specific evidence for an axis investigation, helping distinguish reported feedback faults from a general machine symptom.

Encoder diagnostics Temperature access Maintenance records
Select your currency