Phoenix Contact MACX-MCR-SL-2NAM-T-SP Isolation Amplifier

$ 285.89

Boost safety and accuracy with Phoenix Contact MACX-MCR-SL-2NAM-T-SP, a 2-channel NAMUR isolation amplifier with SIL 2 and 3-way signal separation.

Product Description

Phoenix Contact MACX-MCR-SL-2NAM-T-SP Isolation Amplifier – Safe Signal Separation for NAMUR Sensors

The Phoenix Contact MACX-MCR-SL-2NAM-T-SP isolation amplifier (Article No. 2924281) ensures reliable transmission of NAMUR sensor signals to control systems while maintaining full electrical separation. This two-channel module with 3-way isolation prevents interference and ground loops, enhancing signal clarity and safety in demanding industrial environments. Compact and DIN-rail mountable, it integrates seamlessly into space-limited panels. With built-in line fault detection, selectable operating modes, and SIL 2 certification, the MACX-MCR-SL-2NAM-T-SP is a trusted choice for applications where safe, accurate, and uninterrupted signal processing is critical.

Engineered for process automation and hazardous area use, the MACX-MCR-SL-2NAM-T-SP provides a stable interface between NAMUR sensors and PLC or DCS inputs. Its protective circuits guard against short circuits and line faults, reducing downtime and ensuring system integrity. Clear LED diagnostics simplify troubleshooting, while push-in connections accelerate installation. The amplifier’s high switching frequency capability supports rapid signal processing, and its slim 12.5 mm housing saves cabinet space without sacrificing performance. By improving measurement accuracy, enabling safe integration in Zone 2 environments, and enhancing overall plant reliability, this device delivers long-term operational benefits for system builders and end users alike.

Why Phoenix Contact MACX-MCR-SL-2NAM-T-SP?

The MACX-MCR-SL-2NAM-T-SP stands out because it transforms fragile sensor inputs into clean, reliable signals that your control system can trust. With dual-channel design, SIL 2 safety rating, and intelligent fault monitoring, it ensures operations continue smoothly even in high-risk industrial zones. It’s compact, fast, and built for engineers who demand both safety and efficiency.

What Problem Does It Solve?

This isolation amplifier eliminates one of the biggest headaches in automation—signal errors caused by ground loops, noise, or line faults. By providing robust 3-way isolation and real-time diagnostics, it prevents false readings and system downtime. The result is seamless communication between NAMUR sensors and controllers, ensuring accuracy, reliability, and safer plant operations.

 


Key Features & Specifications – Phoenix Contact MACX-MCR-SL-2NAM-T-SP: 2924281

Feature Details Benefit
Channels 2 independent inputs/outputs Compact design handles multiple signals
Input Type NAMUR proximity sensors, floating contacts Supports standard NAMUR automation signals
Output Type Passive transistor output, up to 5 kHz Fast and interference-free data transfer
Electrical Isolation 3-way isolation (input/output/supply) Prevents ground loops and improves safety
Safety Integrity Level SIL 2 (IEC 61508) Meets strict functional safety requirements
Line Fault Detection Configurable with LED indication Rapid fault identification and minimized downtime
Direction of Operation Selectable (operating or closed circuit) Flexible configuration for diverse control needs
Nominal Supply Voltage 24 V DC (19.2…30 V range) Reliable power with wide operating tolerance
Mounting 12.5 mm slim housing, DIN rail Space-saving design for dense control cabinets
Temperature Range -40 °C to +60 °C Suitable for harsh industrial environments
Certifications ATEX, IECEx, UL, DNV, CE Approved for use in hazardous and global markets

Download MACX-MCR-SL-2NAM-T-SP 2924281 Datasheet

 


Commercial Data – Phoenix Contact MACX-MCR-SL-2NAM-T-SP: 2924281

Commercial Data Details
GTIN Number 4046356491754
Tariff Number 85365019
Weight 163.5 g (with packing), 169.1 g (net)
Country of Origin Germany

 


The Application Examples for Phoenix Contact MACX-MCR-SL-2NAM-T-SP

1. Safe Valve Monitoring in Oil & Gas

Oil and gas facilities rely on NAMUR proximity sensors to confirm valve positions in areas exposed to explosive gases. The MACX-MCR-SL-2NAM-T-SP safely transmits these low-energy signals to control rooms, ensuring compliance with intrinsic safety requirements. Its three-way isolation protects against ground loops, while line fault detection instantly alerts operators if a cable is damaged. This combination reduces risk, ensures uninterrupted monitoring, and supports safe operation of critical flow systems.

2. Pump and Mixer Oversight in Wastewater Plants

Wastewater treatment plants are electrically noisy environments where pumps and mixers run around the clock. The MACX-MCR-SL-2NAM-T-SP filters out interference from heavy motors, guaranteeing clear sensor signals. Maintenance staff benefit from LED fault diagnostics that reveal wiring breaks or corrosion issues early, preventing process disruption. Its compact form allows many amplifiers to be installed side by side, delivering reliable monitoring while saving cabinet space in crowded control rooms.

3. Cleanroom Valve Control in Pharmaceutical Production

In pharmaceutical manufacturing, precise monitoring of valves and flow lines is essential to maintain sterile operations. The MACX-MCR-SL-2NAM-T-SP interfaces with NAMUR sensors to deliver accurate, isolated signals to automation systems. Its selectable operating modes give engineers flexibility during setup, while SIL 2 certification supports strict safety validation. By ensuring dependable signal conversion in compact equipment, it helps production facilities meet regulatory standards and maintain uninterrupted, contamination-free processes.

4. Presence Detection in Automated Factories

Modern production lines use conveyors and robotic systems that rely on sensors to detect product movement and positioning. The MACX-MCR-SL-2NAM-T-SP prevents false readings caused by electrical noise from welding machines and drives. With its high switching frequency capacity, it processes rapid input signals without loss of accuracy. Built-in fault detection minimizes downtime by immediately identifying wiring issues. This makes it an ideal solution for improving efficiency, reducing errors, and keeping manufacturing throughput consistent.

 


Related Products & Accessories – Phoenix Contact MACX-MCR-SL-2NAM-T-SP

Category Product / Accessory Part Number Description & Benefit
Bus & Power Rails ME 6,2 TBUS-2 1,5/5-ST-3,81 GY 2695439 DIN rail bus connector, bridges supply voltage between modules for simplified wiring.
ME 6,2 TBUS-PR-ADAPTER 1136500 Power rail adapter for MACX Analog modules, enables supply via universal power rails.
Separation & Mounting MCR-DP 1430594 Separating plate, ensures isolating distances between Ex i and non-Ex i devices.
TC-2D37SUB-ADIO32-2EX-P-UNI 2904684 Termination carrier for connecting multiple MACX modules to I/O cards.
D-UKK 3/5 / D-UKK 3/5 BU 2770024 / 2770105 End covers for terminal blocks, maintain insulation and safety.
Marking & Identification UC-EMLP / US-EMLP / LS-EMLP Labels 0819291, 0822602, 0824547, 0824548, 0828094, 0828098, 0828789, 0828871, 0828872, 0831678, 0831705, 0831732 Labels and device markers in various sizes/colors for cabinet organization and traceability.
Connection & Wiring MPS-IH Sleeves (WH/RD/BU/YE/GN/GY/BK) 0201663, 0201676, 0201689, 0201692, 0201702, 0201728, 0201731 Insulating sleeves, color-coded for wiring safety and identification.
MPS-MT 0201744 Test plug for fast connection checks during maintenance.
UKK 5-2R/NAMUR 2941662 Terminal block designed for NAMUR applications, secure and robust wiring.
Power & Signaling Modules MACX MCR-PTB / MCR-PTB-SP 2865625 / 2924184 Power and error signaling modules, distribute supply and monitor system faults.
QUINT4-SYS-PS/1AC/24DC/2.5/SC 2904614 QUINT4 power supply, stable 24 V DC source for MACX modules.
Tools & Accessories SZS 0,6X3,5 1205053 Actuation tool for terminal blocks, ensures correct installation and safe tightening.
Monitoring Components FA MCR-FMR Resistor Networks 1642714, 1642715, 1642716, 1642820 Resistor networks for line fault monitoring of NAMUR sensors and floating contacts.

 


Contact Us

For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.

Select your currency