1. Electrical Enable of a Pneumatic Machine Section
A machine controller enables the air supply to a group of pneumatic devices at the start of an operating sequence. This valve supplies a 3/2 normally closed switching function with 24 V DC actuation, connecting the G1/2 branch when commanded. Its 7000 l/min nominal flow and internal pilot arrangement define the component capacity and 4–10 bar supply requirement for that machine section.
Problem Solved
Electrical actuation gives the controller a common supply command for the pneumatic section, while the normally closed spring-return function defines the valve's unactuated circuit state.
3/2 normally closed
24 V DC
7000 l/min nominal
2. Exhausting a Downstream Fixture Branch
A fixture sequence needs to remove its supply command and provide an exhaust path from the controlled branch. The 3/2 valve combines supply switching with a third G1/2 exhaust connection, and mechanical spring reset returns it when electrical actuation is removed. Its exhaust-air function cannot be throttled, so it is suited to an unmetered valve exhaust path rather than adjustable exhaust-speed control.
Problem Solved
The third port provides an exhaust route within the supply-control valve, allowing the sequence to change from feeding the branch to exhausting it through one component.
G1/2 exhaust port
Spring reset
Unthrottled exhaust function
3. On/Off Feeding of a Sustained Air-Blow Station
A production station uses a bank of air-blow nozzles and needs a common electrical feed command during the working interval. The valve offers G1/2 supply and working connections with 7000 l/min nominal flow, providing a documented flow basis for evaluating the nozzle circuit. Its 100% duty rating permits continuous coil energization within the stated operating conditions, rather than limiting the station to brief electrical pulses.
Problem Solved
A continuous-duty coil and common supply valve support sustained commanded air delivery to the nozzle bank, with a defined G1/2 connection and nominal-flow rating.
100% duty cycle
G1/2 working port
7000 l/min nominal