MY-GS – For Control Panel – Omron General Purpose Relays
$ 7.70 – $ 10.56
Miniature Power Relays (MY-GS-R)
Category | Number of poles |
Contact structure |
Plug-in (octal pins) terminals |
||
---|---|---|---|---|---|
With operation indicator | |||||
With latching lever | |||||
Standard models | 2 | Single | MY2-GS-R | MY2N-GS-R | MY2IN-GS-R |
4 | MY4-GS-R | MY4N-GS-R | MY4IN-GS-R | ||
Models with built-in diodes for coil surge absorption |
2 | — | MY2N-D2-GS-R | MY2IN-D2-GS-R | |
4 | — | MY4N-D2-GS-R | MY4IN-D2-GS-R | ||
Models with built-in CR circuits for coil surge absorption |
2 | — | MY2N-CR-GS-R | MY2IN-CR-GS-R | |
4 | — | MY4N-CR-GS-R | MY4IN-CR-GS-R |
Ordering Information
Main unit
Standard model with operation indicator
Number of poles | Model | Rated voltage (V) |
---|---|---|
2 | MY2N-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 220 VDC |
4 | MY4N-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 220 VDC |
Ratings
Main unit
Operating Coil
Item | Rated current (mA) |
Coil resis- tance (Ω) |
Coil inductance (H) |
Must- operate voltage |
Must- release voltage |
Maxi- mum voltage |
Power consumption (VA, W) |
|||
---|---|---|---|---|---|---|---|---|---|---|
Rated voltage | 50 Hz | 60 Hz | Armature OFF |
Armature ON |
Percentage of rated voltage | |||||
AC | 12 | 106.5 | 91 | 46 | 0.17 | 0.33 | 80% max. *1 |
30% min. *2 |
110% | Approx. 0.9 to 1.3 (at 60 Hz) |
24 | 53.8 | 46 | 180 | 0.69 | 1.3 | |||||
48 | 25.7 | 21.1 | 788 | 3.22 | 5.66 | |||||
100/110 | 11.7/12.9 | 10.0/11.0 | 3,750 | 14.54 | 24.6 | |||||
110/120 | 9.9/10.8 | 8.4/9.2 | 4,430 | 19.2 | 32.1 | |||||
200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 94.07 | |||||
220/240 | 5.2/6.2 | 4.3/5.0 | 15,920 | 83.5 | 136.4 | |||||
DC | 6 | 146 (151) | 41.0 (39.8) |
0.17 | 0.33 | 10% min. *2 |
Approx. 0.9 | |||
12 | 72.7 (75) | 165 (160) |
0.73 | 1.37 | ||||||
24 | 36.3 (37.7) | 662 (636) |
3.2 | 5.72 | ||||||
48 | 17.6 (18.8) | 2,725 (2,560) |
10.6 | 21.0 | ||||||
100/110 | 8.7 (9.0)/9.6 (9.9) | 11,440 (11,100) |
45.6 | 86.2 | ||||||
220 | 3.6 | 60,394 | 362.3 | 452.9 | Approx. 0.8 |
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for the AC rated current and +15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The values in parentheses for the rated currents and coil voltages of DC coils are for models with LED operation indicators.
5. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
The Relay will operate if 80% or higher of the rated voltage is applied. However, to achieve the specified characteristics, apply the rated voltage to the coil.
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the specified value.
Contacts
2 poles | 4 poles | |||||
---|---|---|---|---|---|---|
Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
Resistive load | Inductive load (cos φ = 0.4, L/R = 7 ms) |
|||
Contact configuration | DPDT | 4PDT | ||||
Contact structure | Single | |||||
Contact material | Ag | |||||
Rated load | 10 A at 250 VAC 10 A at 30 VDC |
5 A at 220 VDC 5 A at 24 VDC |
2 A at 220 VAC 2 A at 24 VDC |
6 A at 250 VDC 6 A at 30 VDC |
3 A at 220 VDC 3 A at 24 VDC |
0.8 A at 220 VAC 1.5 A at 24 VDC |
Electrical endurance *1 | 100,000 operations |
500,000 operations | 30,000 operations |
200,000 operations | ||
Rated carry current *2 | 10 A | 6 A *2 | ||||
Maximum contact voltage | 250 VAC, 220 VDC | 250 VAC, 220 VDC | ||||
Maximum contact current *2 | 10 A | 6 A *2 | ||||
Maximum switching capacity | 2,500 VA 300 W |
440 VA 48 W |
1,500 VA 180 W |
176 VA 36 W |
||
Minimum load (reference values) *3 |
1 mA at 5 VDC |
*2. 4 poles of 6 A is for an ambient temperature of 50°C. At an ambient temperature of 70°C, the value is 3 A.
*3. These values are guides for the switchable limits for minute load levels, such as in electronic circuits. Actual
characteristics may be different.
in the actual system under actual application conditions.
Characteristics
Main unit
2 poles | 4 poles | ||
Contact resistance *1 | 100 mΩ max. | ||
Operation time *2 | 20 ms max. | ||
Release time *2 | 20 ms max. | ||
Maximum operating frequency | Mechanical | 18, 000 operations/h | |
Rated load | 2,400 operations/h | ||
Insulation resistance *3 | 1,000 MΩ min. | ||
Dielectric strength | Between coil and contacts | 2,000 VAC at 50/60 Hz for 1 min. | |
Between contacts of different polarity | 2,000 VAC at 50/60 Hz for 1 min. | ||
Between contacts of the same polarity | 1,000 VAC at 50/60 Hz for 1 min. | ||
Vibration resistance | Destruction | 10 to 55 to 10 Hz, Double amplitude: 1.0 mm | |
Malfunction | 10 to 55 to 10 Hz, Double amplitude: 1.0 mm | ||
Shock resistance | Destruction | 1,000 m/s2 (approx. 100 G) | |
Malfunction | 200 m/s2 (Approx. 20 G) | ||
Mechanical endurance | 50,000,000 operations (switching frequency: 18,000 operations/h) | ||
Ambient operating temperature | Standard models: -55 to 70°C (with no icing or condensation) | ||
Models with LED operation indicators: -40 to 70°C (with no icing or condensation) | |||
Ambient humidity | 5% to 85% | ||
Weight | Approx. 35 g |
Note: The above values are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*2. Measurement conditions: With rated operating power applied, not including contact bounce time.
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
Weight | N/A |
---|---|
Model | MY4N-GS-R AC110/120, MY4N-GS-R AC12, MY4N-GS-R AC220/240, MY4N-GS-R AC24, MY4N-GS-R AC48, MY4N-GS-R DC100/110, MY4N-GS-R DC12, MY4N-GS-R DC220, MY4N-GS-R DC24, MY4N-GS-R DC48, MY4N-GS-R DC6 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details