H3DK-G – Star-delta Timer – Omron Analog Timers

$ 45.54

SKU: N/A

List of Models

Operating modes Supply voltage Control output H3DK-G
Star-delta Timer 24 to 240 VAC/DC Contact outputs
Delta circuit: SPDT, Star circuit: SPDT
Model H3DK-G
12 VDC Model H3DK-GA
240 to 440 VAC Model H3DK-GE

 

Specifications

Time Ranges

Time range setting t1x1 t1x10
Star set time (t1) range 1 to 12 s 10 to 120 s

 

Star-Delta transfer time (t2) Select from 0.05, 0.1, 0.25, or 0.5 s.

 

Ratings

H3DK-G, -GA H3DK-GE
Power supply voltage *1 24 to 240 VAC/DC, 50/60 Hz *2
12 VDC *2
240 to 440 VAC (50/60 Hz) *5
Allowable voltage fluctuation
range
24 to 240 VAC/DC: 85% to 110% of rated voltage
12 VDC: 90% to 110% of rated voltage
80 % to 110% of rated voltage
Power reset Minimum power-OFF time: 0.5 s
Reset voltage 10% of rated voltage
Power
consumption
H3DK-G At 240 VAC: 6.6 VA max. *3 At 440 VAC: 34 VA max.
H3DK-GA At 12 VDC: 0.9 W max.
Control output Contact output
(Time-limit output: relay,
Star output: SPDT, Delta output: SPDT):
5 A at 250 VAC with resistive load (cosφ = 1),
5 A at 30 VDC with resistive load *3, *4
0.15 A max at 125 VDC with resistive load,
0.1 A at 125 VDC with L/R of 7 ms.
The minimum applicable load is 10 mA at 5 VDC
(Preference value).
Contact materials: Ag-alloy + Gold plating
Contact output:
Ith 2 A
1.5 A at 120 VAC with AC-15,
1 A at 240 VAC with AC-15,
0.3 A at 440 VAC with AC-15,
Contact materials: Ag-alloy + Gold plating
Ambient operating temperature -20 to 55°C (with no icing)
Storage temperature -40 to 70°C (with no icing)
Ambient operating humidity 25% to 85%

 

*1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this
inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such
as a sensor.
*2. DC ripple: 20% max.
*3. Refer to DC Power Consumptions (Reference Information) on Catalog for DC power consumptions.
*4. The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer
to Installation Pitch and Output Switching Capacity (Reference Values) on the Catalog.
*5. For the H3DK-GE, approx. 6 A of inrush current will flow when the power supply is turned ON. When selecting the
device connected to the Timer, allow leeway in the current ratings.

 

Characteristics

H3DK-G, -GA H3DK-GE
Accuracy of operating
time
±1% of FS max.
Setting error ±10% of FS ±0.05 s max.
Transfer time Total error ± (25% of transfer time + 5 ms) max.
Influence of voltage ±0.5% of FS max.
Influence of temperature ±2% of FS max.
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and
exposed non-current-carrying metal parts:
2,000 VAC 50/60 Hz for 1 min.
Between control output terminals and
operating circuit: 2,000 VAC 50/60 Hz for 1
min.
Between contacts not located next to each
other: 1,000 VAC 50/60 Hz for 1 min.
Between current-carrying metal parts and
exposed non-current-carrying metal parts:
2,500 VAC 50/60 Hz for 1 min.
Between control output terminals and
operating circuit: 2,500 VAC 50/60 Hz for 1
min.
Between contacts not located next to each
other: 1,000 VAC 50/60 Hz for 1 min.
Impulse withstand
voltage
H3DK-G:
24 to 240 VAC/VDC: 5 kV between power
terminals, 5 kV between current-carrying
metal parts and exposed non-currentcarrying
metal parts
H3DK-GA:
12 VDC: 1 kV between power terminals, 1.5
kV between current-carrying metal parts and
exposed non-current-carrying metal parts
H3DK-GE: 240 to 440 VAC: 7.5 kV
between power terminals, 7.5 kV
between current-carrying metal
parts and exposed non-currentcarrying
metal parts.
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise):
±1.5 kV *
Static immunity Malfunction: 4 kV, Destruction: 8 kV
Vibration
resistance
Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions
Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Shock
resistance
Destruction 1,000 m/s2 3 times each in 6 directions
Malfunction 100 m/s2 3 times each in 6 directions
Life
expectancy
Mechanical 10 million operations min.
(under no load at 1,800 operations/h)
10 million operations min.
(under no load at 1,800 operations/h)
Electrical 100,000 operations min. (5 A at 250 VAC,
resistive load at 360 operations/h)
100,000 operations min. (0.3 A at 440 VAC,
resistive load at 1,800 operations/h)
Degree of protection IP30 (Terminal block: IP20)
Weight Approx. 120 g

 

* Except for the H3DK-GE

Weight N/A
Model

H3DK-G AC/DC24-240