CS1W-EIP21 – Omron EtherNet/IP Unit
$ 635.80
EtherNet/IP Unit Specifications
Item | Specifications | |
---|---|---|
Model number | CS1W-EIP21/EIP21S | |
Type | 100Base-TX *1 | |
Applicable PLCs | CS-series PLCs *2 | |
Unit classification | CS-series CPU Bus Unit | |
Mounting location | CPU Rack or Expansion Rack | |
Number of Units that can be mounted |
8 max. (including Expansion Racks) | |
CPU Unit words used |
Allocated CIO Area words (CPU Bus Unit words) |
25 words/Unit (one unit number’s words) |
These words contain control bits and flags, the target node PLC’s operating and error information, Unit status, communications status, registered/normal target node information, and FINS/TCP connection status. |
||
Allocated DM Area words (CPU Bus Unit words) |
100 words/Unit (one unit number’s words) | |
These words contain the IP address display/setting area | ||
User-set area | Any usable data area words | |
Target node PLC’s operating and error information, and registered/normal target node information |
||
CPU Bus Unit System Setup |
Not used. | |
Non-volatile memory within EtherNet/IP Unit (See note.) |
The following settings are stored in the EtherNet/IP Unit’s non-volatile memory. Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU Unit is not used for these settings. 1. Unit setup (communications settings for the EtherNet/IP Unit, such as the IP address, DNS server settings, host name, baud rate, FINS/UDP settings, and FINS/ TCP settings) 2. Tag data link settings (device parameters) 3. User authentication settings (CS1W-EIP21S only) 4. Operation log (CS1W-EIP21S only) |
|
Transfer specifi- cations |
Media access method | CSMA/CD |
Modulation method | Baseband | |
Transmission paths | Star form | |
Baud rate | 100 Mbit/s (100Base-TX) | |
Transmission media | Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e |
|
Transmission distance | 100 m (distance between hub and node) | |
Number of cascade connections |
There is no limitation when a switching hub is used. | |
Current consumption (Unit) | CS1W-EIP21: 410 mA max. at 5 V DC CS1W-EIP21S: 620 mA max. at 5 V DC |
|
Weight | CS1W-EIP21: 171 g max. CS1W-EIP21S: 180 g max. |
|
Dimensions | 35 × 130 × 101mm (W × H × D) | |
Other general specifications | Other specifications conform to the general specifications of the CS-series |
*1. If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended.
*2. For the CS1W-EIP21S, the following CPU Units are supported.
CS1G-CPU[][]H, CS1H-CPU[][]H, CS1D-CPU[][]HA/H, CS1D-CPU[][]SA/S, and CS1D-CPU[][]P
Communications Specifications
Item | Specifications | ||
---|---|---|---|
CIP service |
Tag data links (Cyclic communi- cations) |
Number of connections | 256 |
Packet interval (refresh cycle) |
0.5 to 10,000 ms (in 0.5-ms units) Can be set independently for each connection. (Data is refreshed over the network at the preset interval and does not depend on the number of nodes.) |
||
Allowed communications bandwidth per Unit |
6,000 to 12,000 pps *1 *2 Note: Including the heartbeat. |
||
Number of tag sets | 256 | ||
Tag types | CIO Area, DM Area, EM Area, Holding Area, and Work Area | ||
Number of tags per connection (= 1 tag set) |
8 (7 tags when the tag set contains the PLC status) | ||
Maximum link data size per node (total size of all tags) |
184,832 words | ||
Maximum data size per connection |
252 words or 722 words *3 Note: Data synchronicity is maintained within each connection. |
||
Number of registrable tag sets |
256 (1 connection = 1 tag set) |
||
Maximum size of 1 tag set |
722 words (The PLC status uses 1 word when the tag set contains the PLC status.) |
||
Maximum number of tags that can be refreshed per CPU Unit cycle *4 |
Output/Transmission (CPU to EtherNet/IP): 19 Input/Reception (EtherNet/IP to CPU): 20 *5 |
||
Data that can be refreshed per CPU Unit cycle *4 The layout of the allocated CIO Area words is the defauly *6 |
Output/Transmission (CPU to EtherNet/IP): 7,469 words Input/Reception (EtherNet/IP to CPU): 7,469 words |
||
Changing tag data link parameters during operation |
Supported *7 | ||
Multicast packet filter function *8 |
Supported | ||
Explicit messaging |
Class 3 (connected) | Number of connections: 128 | |
UCMM (unconnected) | Number of clients that can communicate at one time: 32 max. Number of servers that can communicate at one time: 32 max. |
||
CIP routing | CS1W-EIP21/EIP21S, CJ1W-EIP21/EIP21S, CJ2H-CPU6[]-EIP, CJ2M-CPU3[] |
||
FINS service *9 | FINS/UDP | Supported | |
FINS/TCP | 16 connections max. | ||
SNMP | Agent | SNMPv1, SNMPv2c, SNMP trap | |
MIB | MIB-II | ||
EtherNet/IP conformance test | CS1W-EIP21S: CT17 CS1W-EIP21: CT11 |
||
Ethernet interface | 10BASE-T or 100BASE-TX Auto Negotiation or fixed settings |
*1. In this case, pps means “packets per second” and indicates the number of packets that can be processed in one
second.
*2. When using CS1W-EIP21S or CS1W-EIP21 with version 3.0 or later.
When using CS1W-EIP21 with version 2.1 or earlier, the allowed communications bandwidth per Unit is 6,000 pps.
*3. To use 505 to 1,444 bytes as the data size, the system must support the Large Forward Open standard (an optional CIP specification). The CS/CJ-series Units support this standard, but before connecting to nodes of other companies, confirm that those devices also support it.
*5. If status layout is set to user settings, the maximum number of tags is as follows.
Condition | Output/Transmission | Input/ Reception |
---|---|---|
CS1W-EIP21S | 18 | 18 |
CS1W-EIP21 | 19 | 19 |
EIP21 | EIP21S | ||
---|---|---|---|
Data (words) that can be refleshed per CPU Unit cycle |
Output/Transmission | 7405 | 7321 |
Input/Reception |
*7. If parameters are changed in the EtherNet/IP Unit, however, the EtherNet/IP Unit will be restarted. When other nodes are communicating with the affected node, the communications will temporarily time out and automatically recover later.
*9. The EtherNet/IP Unit uses the TCP/UDP port numbers shown in the following table.
Service | Protocol | Port number | Remarks |
---|---|---|---|
Tag data links | UDP | 2222 | The port number is fixed. |
Class 3, UCMM | TCP/UDP | 44818 | |
DNS | UDP | 53 | |
Secure Comm | TCP | 443 | The port number is fixed. It is supported by the CS1W-EIP21S only. |
FINS/UDP service | UDP | 9600 | Port numbers in the Unit Setup can be changed with the CX-Programmer. |
FINS/TCP service | TCP | 9600 | |
FTP | TCP | 20, 21 | |
SNTP | UDP | 123 | |
SNMP | UDP | 161 | |
SNMP trap | UDP | 162 |
Network Configurator Requirements
The Network Configurator is a software package designed for building, setting, and controlling a multi-vendor EtherNet/IP Network using OMRON’s EtherNet/IP. It is included in CX-One.
CS1W-EIP21 EtherNet/IP Unit. Network Configurator version 3.0 or higher is included with CX-One version 3.0 or higher.
CS1W-EIP21S EtherNet/IP Unit. Network Configurator version 3.73 or higher is included with CX-One version 4.61 or higher.
The Network Configurator provides the following functions for building, setting, and controlling EtherNet/IP.
Item | Specification | ||
---|---|---|---|
System Requirements | Refer to the CX-One Catalog (Cat. No. R134), visit your local OMRON website. | ||
Network connection method |
CS1/CJ1 | CJ2 | |
Serial interface | CPU Unit’s Peripheral or RS-232C port | CPU Unit’s USB or RS-232C port | |
Ethernet interface | EtherNet/IP Unit’s Ethernet port | CPU Unit’s Ethernet port EtherNet/IP Unit’s Ethernet port |
|
Location on Network | A single node address is used (only when directly connected to EtherNet/IP). | ||
Number of Units that can be connected to Network |
A single Network Configurator per Network (More than one Configurator cannot be used in the same system.) |
||
Main functions |
Network control functions |
•The Network configuration can be created and edited regardless of whether the Network Configurator is online or offline. •The Network configuration can be read from a file or the network. |
|
Configuration functions |
The EDS files used by the Network Configurator can be installed and deleted. | ||
Supported file formats | Configurator network configuration files (*.ncf) Configuration files (*.ncf) created using the Network Configurator for EtherNet/IP (version 2) can be imported by selecting External Data – Import from the File Menu. |