Domestic TeSys Deca GV2 – GV2PM – Thermal Magnetic Motor Circuit Breakers – Schneider Circuit Breakers
$ 30.80 – $ 39.16
SKU: N/A
Specifications
Main information | ||||
Part Number | GV2PM07C | GV2PM10C | GV2PM16C | GV2PM20C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product name | TeSys GV2 | TeSys GV2 | TeSys GV2 | TeSys GV2 |
product short name | GV2PM | GV2PM | GV2PM | GV2PM |
product type | Breaker | Breaker | Breaker | Breaker |
Applications | Motor protection | Motor protection | Motor protection | Motor protection |
number of poles | 3P | 3P | 3P | 3P |
Additional information | ||||
Grid type | AC | AC | AC | AC |
Network frequency | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 |
control type | Knob | Knob | Knob | Knob |
installation method | Rail installation | Rail installation | Rail installation | Rail installation |
installation location | Vertical | Vertical | Vertical | Vertical |
horizontal direction | horizontal direction | horizontal direction | horizontal direction | |
Motor power (kW) | 0.37 kW at 230 V AC 50/60 Hz | 1.1 kW at 230 V AC 50/60 Hz | 3 kW at 230 V AC 50/60 Hz | 4 kW at 230 V AC 50/60 Hz |
0.75 kW at 400 V | 2.2 kW at 400 V | 5.5 kW at 400 V | 7.5 kW at 400 V | |
0.75 kW at 415 V | 2.2 kW at 415 V | 5.5 kW at 415 V | 9 kW at 415 V | |
1.1 kW at 440 V AC 50/60 Hz | 3 kW at 440 V AC 50/60 Hz | 7.5 kW at 440 V AC 50/60 Hz | 9 kW at 440 V AC 50/60 Hz | |
Rated current [In] | 2.5A | 6.3A | 14A | 18A |
Trip unit type | Thermomagnetic | Thermomagnetic | Thermomagnetic | Thermomagnetic |
Electromagnetic trip current | 33.5A | 78A | 170A | 223A |
Thermal overload protection setting range | 1.6…2.5 A | 4…6.3A | 9…14A | 13…18A |
isolation function | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 |
Mechanical shock resistance | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 |
phase loss sensitivity | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 |
use category | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 |
AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | |
Rated working voltage [Ue] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated insulation voltage [Ui] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | |
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | |
Conventional thermal current [Ith] | 2.5 A conforming to IEC 60947-4-1 | 6.3 A conforming to IEC 60947-4-1 | 13 A conforming to IEC 60947-4-1 | 17 A conforming to IEC 60947-4-1 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 |
power consumption per pole | 2.5W | 2.5W | 2.5W | 2.5W |
Mechanical life | 100000 times | 100000 times | 100000 times | 100000 times |
Electrical life | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In |
100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | |
maximum conversions | 25 cyc/h | 25 cyc/h | 25 cyc/h | 25 cyc/h |
specified load | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 |
Wiring capacity | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: |
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | |
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | |
Tightening torque | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² |
1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | |
1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | |
Breaking capacity | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 3 kA at 690 V AC 50/ 60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 | |
Rated operating short-circuit breaking capacity [Ics] | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | ||
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | ||
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |||
high | 89 mm | 89 mm | 89 mm | 89mm |
width | 44.5 mm | 44.5 mm | 44.5 mm | 44.5 mm |
depth | 91 mm | 91 mm | 91 mm | 91 mm |
product weight | 0.26kg | 0.26kg | 0.26kg | 0.26kg |
Environment | ||||
Standards compliant | GB 14048.4 | GB 14048.4 | GB 14048.4 | GB 14048.4 |
IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | |
IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | |
IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | |
certified product | CCC | CCC | CCC | CCC |
UKCA | UKCA | UKCA | UKCA | |
CE | CE | CE | CE | |
Protective measures | TH | TH | TH | TH |
IP protection class | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) |
Shock and vibration resistance | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 |
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | |
ambient temperature | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet |
-20…60 °C Body | -20…60 °C Body | -20…60 °C Body | -20…60 °C Body | |
storage environment temperature | -40…80°C | -40…80°C | -40…80°C | -40…80°C |
Fire resistance and abnormal high temperature resistance | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 |
working altitude | <= 2000m | <= 2000m | <= 2000m | <= 2000m |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5.6cm | 5.218 cm | 4.79cm | 5.6cm |
Package 1 Width | 9.4 cm | 9.3 cm | 9.09 cm | 9.8 cm |
Package 1 Length | 9.9 cm | 9.685 cm | 9.61 cm | 10.2 cm |
Package 1 Weight | 284.3g | 298.0g | 305.25g | 312.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 20 | 20 | 20 | 20 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 6.078 kg | 6.369 kg | 6.497 kg | 6.636 kg |
Unit Type of Package 3 | P06 | P06 | P06 | P06 |
Number of Units in Package 3 | 400 | 400 | 400 | 400 |
Package 3 Height | 90.0cm | 90.0cm | 90.0cm | 90.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 131.56kg | 137.38kg | 139.94kg | 142.72kg |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main information | |||
Part Number | GV2PM21C | GV2PM22C | GV2PM32C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
product name | TeSys GV2 | TeSys GV2 | TeSys GV2 |
product short name | GV2PM | GV2PM | GV2PM |
product type | Breaker | Breaker | Breaker |
Applications | Motor protection | Motor protection | Motor protection |
number of poles | 3P | 3P | 3P |
Additional information | |||
Grid type | AC | AC | AC |
Network frequency | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 |
control type | Knob | Knob | Knob |
installation type | Fixed | ||
installation method | Rail installation | Rail installation | Rail installation |
installation location | Vertical | horizontal | Vertical |
horizontal direction | Vertical | horizontal direction | |
Motor power (kW) | 5.5 kW at 230 V AC 50/60 Hz | 5.5 kW at 230 V AC 50/60 Hz | 7.5 kW at 230 V AC 50/60 Hz |
11 kW at 400 V | 11 kW at 400 V | 15 kW at 400 V | |
11 kW at 415 V | 11 kW at 415 V | 15 kW at 415 V | |
11 kW at 440 V AC 50/60 Hz | 11 kW at 440 V AC 50/60 Hz | 15 kW at 440 V AC 50/60 Hz | |
Rated current [In] | 23A | 25A | 32A |
Trip unit type | Thermomagnetic | Thermomagnetic | Thermomagnetic |
Electromagnetic trip current | 327A | 327A | 416A |
Thermal overload protection setting range | 17…23A | 20…25A | 24…32A |
isolation function | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 |
Mechanical shock resistance | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 |
phase loss sensitivity | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 |
use category | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 |
AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | |
Rated working voltage [Ue] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated insulation voltage [Ui] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | |
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | |
Conventional thermal current [Ith] | 21 A conforming to IEC 60947-4-1 | 23 A conforming to IEC 60947-4-1 | 24 A conforming to IEC 60947-4-1 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 |
power consumption per pole | 2.5W | 2.5W | 2.5W |
Mechanical life | 100000 times | 100000 times | 100000 times |
Electrical life | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In |
100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | |
maximum conversions | 25 cyc/h | 25 cyc/h | 25 cyc/h |
specified load | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 |
Wiring capacity | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: |
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | |
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | |
Tightening torque | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² |
1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | |
1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | |
Breaking capacity | Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 10 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Rated operating short-circuit breaking capacity [Ics] | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | 40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
high | 89mm | 89 mm | 89 mm |
width | 44.5 mm | 44.5 mm | 44.5 mm |
depth | 91 mm | 91 mm | 91 mm |
product weight | 0.26kg | 0.26kg | 0.26kg |
Environment | |||
Standards compliant | GB 14048.4 | GB 14048.4 | GB 14048.4 |
IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | |
IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | |
IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | |
certified product | CCC | CCC | CCC |
UKCA | UKCA | UKCA | |
CE | CE | CE | |
Protective measures | TH | TH | TH |
IP protection class | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) |
Shock and vibration resistance | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 |
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | |
ambient temperature | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet |
-20…60 °C Body | -20…60 °C Body | -20…60 °C Body | |
storage environment temperature | -40…80°C | -40…80°C | -40…80°C |
Fire resistance and abnormal high temperature resistance | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 |
working altitude | <= 2000m | <= 2000m | <= 2000m |
Packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 5.152 cm | 9.03 cm | 9.05cm |
Package 1 Width | 9.038 cm | 9.35cm | 9.34 cm |
Package 1 Length | 9.331 cm | 4.88cm | 4.78cm |
Package 1 Weight | 314.5g | 308.65g | 305.85 g |
Unit Type of Package 2 | S02 | S02 | S02 |
Number of Units in Package 2 | 20 | 20 | 20 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 6.63kg | 6.565kg | 6.509kg |
Unit Type of Package 3 | P06 | P06 | P06 |
Number of Units in Package 3 | 400 | 400 | 400 |
Package 3 Height | 90.0cm | 90.0cm | 90.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 142.6 kg | 141.3kg | 140.18kg |
Contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Amp a | 14, 18, 2.5, 23, 25, 32, 6.3 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details