| Main | |||
| Part Number | XCKT2102P16 | XCKT2111P16 | XCKT2110P16 |
| Range of product | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
| Series name | Standard format | Standard format | Standard format |
| Product or component type | Limit switch | Limit switch | Limit switch |
| device short name | XCKT | XCKT | XCKT |
| Sensor design | Compact form C conforming to CENELEC EN 50047 | Compact | Compact form B conforming to CENELEC EN 50047 |
| body type | Fixed | Fixed | Fixed |
| Head type | Plunger head | Plunger head | Plunger head |
| Material | Plastic | Plastic | Plastic |
| Body material | Plastic | Plastic | Plastic |
| Head material | Zamak | Zamak | Zamak |
| Fixing mode | By the body | By the body | By the body |
| Movement of operating head | Linear | Linear | Linear |
| Type of operator | Spring return roller plunger metal | Spring return roller plunger metal with nitrile boot | Spring return plunger metal |
| Type of approach | Lateral approach, 2 directions | Vertical approach, 1 direction | Vertical approach, 1 direction |
| Number of poles | 2 | 2 | 2 |
| Contacts type and composition | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
| Contact operation | Snap action | Snap action | Snap action |
| Complementary | |||
| Switch actuation | By 30° cam | On end | On end |
| Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
| Cable entry | 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm | 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm | 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm |
| Contacts insulation form | Zb | Zb | Zb |
| Positive opening | With | With | With |
| Positive opening minimum force | 36 N | 45 N | 45 N |
| Minimum force for tripping | 12 N | 15 N | 15 N |
| Maximum actuation speed | 0.5 m/s | 0.01 m/min | 0.01 m/min |
| Repeat accuracy | 0.1 mm on the tripping points with 1 million operating cycles | 0.5 m/s | 0.5 m/s |
| Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A | 0.1 mm on the tripping points with 1 million operating cycles | 0.1 mm on the tripping points with 1 million operating cycles |
| Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A | |
| [Ui] rated insulation voltage | 300 V conforming to UL 508 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
| 500 V (pollution degree 3) conforming to IEC 60947-1 | 300 V conforming to UL 508 | 300 V conforming to UL 508 | |
| 300 V conforming to CSA C22.2 No 14 | 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) conforming to IEC 60947-1 | |
| Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 300 V conforming to CSA C22.2 No 14 | 300 V conforming to CSA C22.2 No 14 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MOhm conforming to IEC 60255-7 category 3 |
| 6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60664 | 6 kV conforming to IEC 60664 | |
| Short-circuit protection | 10 A cartridge fuse, type gG | 6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60947-1 |
| Electrical durability | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 10 A cartridge fuse, type gG | 10 A cartridge fuse, type gG |
| 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
| 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
| 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | ||
| Mechanical durability | 10000000 cycles | 15000000 cycles | 15000000 cycles |
| Width | 58 mm | 58 mm | 58 mm |
| Height | 51 mm | 51 mm | 51 mm |
| Depth | 30 mm | 30 mm | 30 mm |
| Product weight | 0.105 kg | 0.1 kg | 0.1 kg |
| Terminals description ISO n°1 | (21-22)NC | (13-14)NO | (21-22)NC |
| (13-14)NO | (21-22)NC | (13-14)NO | |
| Environment | |||
| Shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 |
| Vibration resistance | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 |
| IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | |
| IK degree of protection | IK04 conforming to EN 50102 | IK04 conforming to EN 50102 | IK04 conforming to EN 50102 |
| Electrical shock protection class | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 |
| Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | |
| Ambient air temperature for operation | -25…70 °C | -25…70 °C | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C | -40…70 °C | -40…70 °C |
| Protective treatment | TC | TC | TC |
| Product certifications | CSA | UL | CCC |
| UL | CSA | CSA | |
| CCC | CCC | UL | |
| Standards | UL 508 | UL 508 | EN/IEC 60947-5-1 |
| EN/IEC 60204-1 | EN/IEC 60204-1 | UL 508 | |
| EN/IEC 60947-5-1 | CSA C22.2 No 14 | EN/IEC 60204-1 | |
| CSA C22.2 No 14 | EN/IEC 60947-5-1 | CSA C22.2 No 14 | |
| Packing Units | |||
| Unit Type of Package 1 | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 |
| Package 1 Height | 3.3 cm | 3.4 cm | 3.3 cm |
| Package 1 Width | 6.4 cm | 6.5 cm | 6.4 cm |
| Package 1 Length | 9.8 cm | 10.0 cm | 9.8 cm |
| Package 1 Weight | 95.0 g | 92.0 g | 88 g |
| Unit Type of Package 2 | S02 | S02 | S02 |
| Number of Units in Package 2 | 58 | 50 | 58 |
| Package 2 Height | 15.0 cm | 15.0 cm | 15 cm |
| Package 2 Width | 30.0 cm | 30.0 cm | 30 cm |
| Package 2 Length | 40.0 cm | 40.0 cm | 40 cm |
| Package 2 Weight | 6.005 kg | 5.001 kg | 5.6 kg |
| Contractual warranty | |||
| Warranty | 18 months | 18 months | 18 months |