Main | ||||
Part Number | XCKD2121P16 | XCKD2102P16 | XCKD2106P16 | XCKD2110P16 |
Range of product | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
Series name | Standard format | Standard type | Standard type | Standard type |
Product or component type | Limit switch | Limit switch | Limit switch | Limit switch |
device short name | XCKD | XCKD | XCKD | XCKD |
Sensor design | Compact form E conforming to CENELEC EN 50047 | Compact Type C according to CENELEC EN 50047 | Compact | Compact Type B according to CENELEC EN 50047 |
body type | Fixed | Fixed | Fixed | Fixed |
Head type | Plunger head | Direct acting head | Universal head | Direct acting head |
Material | Metal | Metal | Metal | Metal |
Body material | Zamak | Zamak | Zamak | Zamak |
Head material | Zamak | Zamak | Zamak | Zamak |
Fixing mode | By the body | By ontology | By ontology | By ontology |
Movement of operating head | Linear | Linear | Universal | Linear |
Type of operator | Spring return roller lever plunger thermoplastic | Spring Return, Roller Direct Action Metal | Spring return whisker | Spring return direct acting metal |
Type of approach | Lateral approach, 1 direction | Lateral movement, 2-way | Universal motion | Vertical movement, one-way |
Number of poles | 2 | 2 | 2 | 2 |
Contacts type and composition | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
Contact operation | Snap action | Momentary | Momentary | Momentary |
Complementary | ||||
Switch actuation | By 30° cam | 30° lip | Any moving parts | The end |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Cable entry | 1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm | One for M16x1.5 cable gland, cable outer diameter: 4…8 mm | One for M16x1.5 cable gland, cable outer diameter: 4…8 mm | One for M16x1.5 cable gland, cable outer diameter: 4…8 mm |
Contacts insulation form | Zb | Zb | Zb | Zb |
Positive opening | With | Have | None | Have |
Positive opening minimum force | 18 N | 36 N | 45N | |
Minimum trigger torque | 0.13 Nm | |||
Minimum force for tripping | 6 N | 12N | 15N | |
minimum braking speed | 0.01 m/min | |||
Maximum actuation speed | 1 m/s | 0.5 m/s | 1 m/s | 0.5 m/s |
Repeat accuracy | 0.1 mm on the tripping points with 1 million operating cycles | Trigger point is 0.1mm 1 million operating cycles | Trigger point is 0.1mm 1 million operating cycles | Trigger point is 0.1mm 1 million operating cycles |
Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A | |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A | |
[Ui] rated insulation voltage | 300 V conforming to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 |
500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | |
300 V conforming to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 |
6 kV conforming to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | |
Short-circuit protection | 10 A cartridge fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG |
Electrical durability | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W | 5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W | 5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W |
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C | , Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C | , Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C | , Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C | |
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C | |
Mechanical durability | 15000000 cycles | 10000000 times | 5000000 times | 15000000 times |
Width | 31 mm | 31 mm | 31 mm | 31 mm |
Height | 65 mm | 65 mm | 65 mm | 65 mm |
Depth | 30 mm | 30 mm | 30 mm | 30 mm |
Product weight | 0.195 kg | 0.185kg | 0.175kg | 0.18kg |
Terminals description ISO n°1 | (13-14)NO | (21-22)NC | (21-22)NC | (21-22)NC |
(21-22)NC | (13-14)NO | (13-14)NO | (13-14)NO | |
Environment | ||||
Shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration resistance | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP66 conforming to IEC 60529 | IP66 conforms to screwed | IP66 conforms to screwed | IP66 conforms to screwed |
IP67 conforming to IEC 60529 | IP67 conforms to screwed | IP67 conforms to screwed | IP67 conforms to screwed | |
IK degree of protection | IK06 conforming to EN 50102 | IK06 conforms to EN 50102 | IK06 conforms to EN 50102 | IK06 conforms to EN 50102 |
Electrical shock protection class | Class I conforming to IEC 61140 | Class I conforming to IEC 61140 | Class I conforming to IEC 61140 | Class I conforming to IEC 61140 |
Class I conforming to NF C 20-030 | Class I conforming to NF C 20-030 | Class I conforming to NF C 20-030 | Class I conforming to NF C 20-030 | |
Ambient air temperature for operation | -25…70 °C | -25…70°C | -25…70°C | -25…70°C |
Ambient air temperature for storage | -40…70 °C | -40…70°C | -40…70°C | -40…70°C |
Protective treatment | TC | TC | TC | TC |
Product certifications | UL | CCC | CCC | CCC |
CSA | UL | CSA | UL | |
CCC | CSA | UL | CSA | |
Standards | EN 60947-5-1 | IEC 60947-5-1 | IEC 60947-5-1 | IEC 60947-5-1 |
IEC 60947-5-1 | CSA C22.2 No 14 | CSA C22.2 No 14 | EN 60947-5-1 | |
UL 508 | IEC 60204-1 | EN 60204-1 | CSA C22.2 No 14 | |
IEC 60204-1 | EN 60204-1 | EN 60947-5-1 | IEC 60204-1 | |
EN 60204-1 | UL 508 | UL 508 | EN 60204-1 | |
CSA C22.2 No 14 | EN 60947-5-1 | IEC 60204-1 | UL 508 | |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 3.5 cm | 3.0cm | 3.4cm | 3.8cm |
Package 1 Width | 4.0 cm | 5.0cm | 4cm | 5.4 cm |
Package 1 Length | 10.3 cm | 11.8 cm | 20.6cm | 10.2 cm |
Package 1 Weight | 174.0 g | 166.0g | 168g | 160.0g |
Unit Type of Package 2 | S01 | S01 | S01 | S01 |
Number of Units in Package 2 | 22 | 22 | 12 | 27 |
Package 2 Height | 15.0 cm | 15.0cm | 15cm | 15.0cm |
Package 2 Width | 15.0 cm | 15.0cm | 15cm | 15.0cm |
Package 2 Length | 40.0 cm | 40.0cm | 40cm | 40.0cm |
Package 2 Weight | 4.091 kg | 3.918 kg | 2.349 kg | 4.642kg |
Contractual warranty | ||||
Warranty | 18 months | 18 month | 18 months | 18 months |
Main information | |||
Part Number | XCKD2118P16 | XCKD2127P16 | XCKD2145P16 |
Product Series | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
Serial Number | Standard type | Standard type | Standard type |
product type | Limit switch | Limit switch | Limit switch |
product short name | XCKD | XCKD | XCKD |
sensor design | Compact Type A conforming to CENELEC EN 50047 | Compact | Compact |
ontology type | Fixed | Fixed | Fixed |
Control head type | Swivel head | Direct acting head | Swivel head |
Material | Metal | Metal | Metal |
body material | Zamak | Zamak | Zamak |
head material | Zamak | Zamak | Zamak |
fixed mode | By ontology | By ontology | By ontology |
Operation head movement | To rotate | Linear | To rotate |
Operating head type | Spring Return Roller Rocker Thermoplastic | Spring Return Roller Direct Acting Thermoplastic | Spring Return Roller Rocker Thermoplastic Variable Length |
method type | Lateral movement, 2-way | Vertical movement, one-way | Lateral movement, 2-way |
number of poles | 2 | 2 | 2 |
contact type | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
contact action | Momentary | Momentary | Momentary |
Additional information | |||
track | 24/40 mm | ||
switch trigger | 30° lip | 30° lip | 30° lip |
Electrical connections | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
cable entry hole | One for M16x1.5 cable gland, cable outer diameter: 4…8 mm | One for M16x1.5 cable gland, cable outer diameter: 4…8 mm | One for M16x1.5 cable gland, cable outer diameter: 4…8 mm |
Type of contact wire insulation | Zb | Zb | Zb |
force open | Have | Have | Have |
Force open minimum torque | 0.25 Nm | 0.25 Nm | |
Minimum trigger torque | 0.1 Nm | 0.1 Nm | |
force open minimum force | 18N | ||
Minimum trip force | 6N | ||
operating speed | 1.5 m/s | 1 m/s | 1.5 m/s |
Repeatability | Trigger point is 0.1mm 1 million operating cycles | Trigger point is 0.1mm 1 million operating cycles | Trigger point is 0.1mm 1 million operating cycles |
Contact wire regulation grade | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN 60947-5-1 |
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming IEC 60947-5-1 Annex A | |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 | |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947 -5-1 Appendix A | |
Rated insulation voltage [Ui] | 300 V according to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 |
500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | |
300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
Maximum resistance across terminals | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 |
6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | |
Short circuit protection | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG |
Electrical life | 5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W | 5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W | 5000000 cycles, DC-13, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, 24 V, 10 W |
, Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C | , Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C | , Operating rating <60 cycles/min, duty factor: 0.5, DC conforming to IEC 60947-5-1 Annex C | |
5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 , DC conforming to IEC 60947-5-1 Appendix C | |
Mechanical life | 10000000 times | 15000000 times | 10000000 times |
width | 31 mm | 31 mm | 31 mm |
high | 65 mm | 65 mm | 65 mm |
depth | 30 mm | 30 mm | 30 mm |
product weight | 0.225 kg | 0.19 kg | 0.235 kg |
ISO n°1 terminals | (21-22)NC | (21-22)NC | (21-22)NC |
(13-14)NO | (13-14)NO | (13-14)NO | |
Environment | |||
impact resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 |
Anti-vibration | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP protection class | IP66 conforms to screwed | IP66 conforms to screwed | IP66 conforms to screwed |
IP67 conforms to screwed | IP67 conforms to screwed | IP67 conforms to screwed | |
IK protection class | IK06 conforms to EN 50102 | IK06 conforms to EN 50102 | IK06 conforms to EN 50102 |
Electric Shock Protection Level | Class I conforming to IEC 61140 | Class I conforming to IEC 61140 | Class I conforming to IEC 61140 |
Class I conforming to NF C 20-030 | Class I conforming to NF C 20-030 | Class I conforming to NF C 20-030 | |
operating temperature | -25…70°C | -25…70°C | -25…70°C |
storage environment temperature | -40…70°C | -40…70°C | -40…70°C |
Protective treatment | TC | TC | TC |
certified product | UL | CCC | CCC |
CCC | CSA | UL | |
CSA | UL | CSA | |
Standards compliant | UL 508 | EN 60204-1 | UL 508 |
EN 60204-1 | IEC 60947-5-1 | EN 60947-5-1 | |
IEC 60204-1 | CSA C22.2 No 14 | IEC 60204-1 | |
EN 60947-5-1 | IEC 60204-1 | CSA C22.2 No 14 | |
IEC 60947-5-1 | EN 60947-5-1 | EN 60204-1 | |
CSA C22.2 No 14 | UL 508 | IEC 60947-5-1 | |
Packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 3.4cm | 3.4cm | 3.4cm |
Package 1 Width | 4.8cm | 4.5cm | 5.0cm |
Package 1 Length | 13.0cm | 10.6 cm | 13.0cm |
Package 1 Weight | 207.0g | 176.0g | 215.0g |
Unit Type of Package 2 | S01 | S01 | S01 |
Number of Units in Package 2 | Twenty one | Twenty four | Twenty one |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 15.0cm | 15.0cm | 15.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 4.578 kg | 4.456 kg | 4.751kg |
Contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Model | XCKD2102P16, XCKD2106P16, XCKD2110P16, XCKD2118P16, XCKD2121P16, XCKD2127P16, XCKD2145P16 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details