OD2-N85W20I2 Displacement Measurement Sensors – SICK Sensor
$ 646.58
SKU: SICK 6036601
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6036601
Distance Sensor Model: OD2-N85W20I2
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 12 V … 24 V |
Power consumption | ≤ 2.88 W 1) |
Warm-up time | ≤ 30 min |
Housing material | Plastic (PBT) |
Window material | Plastic (PMMA) |
Connection type | Cable, 2 m |
Indication | Distance bar graph, up to 8 status LEDs |
Weight | 70 g |
Dimensions (W x H x D) | 20.4 mm x 60 mm x 50 mm |
Enclosure rating | IP67 |
Protection class | III |
- 1) Without load, with current output.
Performance
Measuring range | 65 mm … 105 mm 1) |
Target | Natural objects |
Repeatability | 10 µm 1) 2) 3) |
Linearity | ± 40 µm 2) 4) 5) |
Response time | ≥ 1 ms |
Measuring frequency | ≤ 2 kHz 1) |
Output time | ≥ 0.5 ms |
Light source | Laser, red visible red light |
Laser class | 2 (IEC 60825-1:2014, EN 60825-1:2014) 6) |
Typ. light spot size (distance) | 0.8 mm x 1.3 mm (85 mm) |
Additional function | Mean-value setting 1 … 64x, automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of digital output, Invertable switching output, multifunctional input: laser-off / external teach-in / trigger, switching mode: distance to object (DtO), switching mode: window (Wnd) |
- 1) 6 % … 90 % remission.
- 2) At averaging function medium.
- 3) Constant ambient conditions.
- 4) Measurement on 90 % remission (ceramic, white).
- 5) When calibrated in the application regularly.
- 6) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
|
|||||||||||
|
|||||||||||
Multifunctional input (MF) | 1 x MF 2) |
- 1) PNP: HIGH = VS – (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS.
- 2) MF can be used as laser-off, trigger, external teach-in, or deactivated; response time ≤ 3 ms.
Ambient data
Ambient temperature, operation | –10 °C … +40 °C |
Ambient temperature, storage | –20 °C … +60 °C |
Relative air humidity (non-condensing) | 35 % … 95 % |
Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
Typ. Ambient light immunity | Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx |
Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
Shock resistance | 50 G (x, y, z axis 3 times each) |
Shock resistance | 50 G (x, y, z axis 3 times each) |
Weight | 0.227 kg |
---|---|