GA-311/GH Series – Compact Inductive Proximity Sensor – Panasonic Inductive Sensors

$ 51.92

SKU: GH-2SE

Specification

Item Specifications
Product Number GH-2SE
Part Number GH-2SE
Applicable amplifier GA-311
Stable sensing range 0 to 0.6 mm 0 to 0.024 in
(Note:The stable sensing range represents the sensing range for which the sensor can satisfy all the given specifications with the standard sensing object.)
Max. operation distance 1.2 mm 0.047 in
(Note:The maximum operation distance represents the maximum distance for which the sensor can detect the standard sensing object at +20 degrees +68degrees Fahrenheit constant ambient temperature.
Usage within the stable sensing range is recommended for accurate sensing applications.)
Standard sensing object Iron sheet 5 × 5 × t 1 mm
0.197 × 0.197 × t 0.039 in
Hysteresis 0.07 mm
0.003 in or less
(Note:The hysteresis and the repeatability are specified for the standard sensing object within the stable sensing range.)
Repeatability Along sensing axis, perpendicular to sensing axis: 1 μm 0.039 mil or less
(Note:The hysteresis and the repeatability are specified for the standard sensing object within the stable sensing range.)
Protection IP50 (IEC)
Ambient temperature -10 to +60 ℃ 14 to +140 ℉, Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Temperature characteristics Within plus or minus 7 %
(Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may deteriorate due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Material Enclosure: Stainless steel (SUS303)
Sensing part: PVC
Cable Oil-resistant [Spatter-resistant type: Spatter-resistant cable (Sheath: Fluorine resin)] high-frequency coaxial cable,
3 m 9.843 ft long, with a connector at the end
(Note:The value represents the variation in the operation distance, that has been set within the stable sensing range at +20 ℃ +68 ℉, for an ambient temperature drift from 0 to +55 ℃ +32 to +131 ℉. (Values are for sensor head only.))
Weight Net weight: 15 g approx.
Gross weight: 30 g approx.
Weight 0.015 kg