$ 95.22
| Part Number | 3RV2011-1JA10 | 3RV2011-1HA20 |
| product brand name | SIRIUS | SIRIUS |
| product designation | Circuit breaker | Circuit breaker |
| design of the product | For motor protection | For motor protection |
| product type designation | 3RV2 | 3RV2 |
| General technical data | ||
| size of the circuit-breaker | S00 | S00 |
| size of contactor can be combined company-specific | S00,S0 | S00,S0 |
| product extension auxiliary switch | Yes | Yes |
| power loss [W] for rated value of the current | ||
| ● at AC in hot operating state 9.25 W | 9.25 W | 9.25 W |
| ● at AC in hot operating state per pole 3.1 W | 3.1W | 3.1W |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V | 690 V |
| surge voltage resistance rated value 6 kV | 6 kV | 6 kV |
| shock resistance according to IEC 60068-2-27 | 25g / 11 ms | 25g / 11 ms |
| mechanical service life (operating cycles) | ||
| ● of the main contacts typical | 100 000 | 100 000 |
| ● of auxiliary contacts typical | 100 000 | 100 000 |
| electrical endurance (operating cycles) typical | 100 000 | 100 000 |
| type of protection according to ATEX directive 2014/34/EU |
Ex II (2) GD | Ex II (2) GD |
| certificate of suitability according to ATEX directive 2014/34/EU |
DMT 02 ATEX F 001 | DMT 02 ATEX F 001 |
| reference code according to IEC 81346-2 | Q | Q |
| Substance Prohibitance (Date) 10/01/2009 | 10/1/2009 | 10/1/2009 |
| Ambient conditions | ||
| installation altitude at height above sea level maximum | 2 000 m | |
| ambient temperature | ||
| ● during operation | -20 … +60 °C | -20 … +60 °C |
| ● during storage | -50 … +80 °C | -50 … +80 °C |
| ● during transport | -50 … +80 °C | -50 … +80 °C |
| relative humidity during operation | 10 … 95 % | 10 … 95 % |
| Main circuit | ||
| number of poles for main current circuit | 3 | 3 |
| adjustable current response value current of the current-dependent overload release |
7 … 10 A | 5.5 … 8 A |
| operating voltage | ||
| ● rated value | 20 … 690 V | 20 … 690 V |
| ● at AC-3 rated value maximum | 690 V | 690 V |
| ● at AC-3e rated value maximum | 690 V | 690 V |
| operating frequency rated value | 50 … 60 Hz | 50 … 60 Hz |
| operational current rated value | 10 A | 8 A |
| operational current | ||
| ● at AC-3 at 400 V rated value | 10 A | 8 A |
| ● at AC-3e at 400 V rated value | 10 A | 8 A |
| operating power | ||
| ● at AC-3 | ||
| — at 230 V rated value | 2.2 kW | 1.5 kW |
| — at 400 V rated value | 4 kW | 3 kW |
| — at 500 V rated value | 5.5 kW | 4 kW |
| — at 690 V rated value | 7.5 kW | 5.5 kW |
| ● at AC-3e | ||
| — at 230 V rated value | 2.2 kW | 1.5 kW |
| — at 400 V rated value | 4 kW | 3 kW |
| — at 500 V rated value | 5.5 kW | 4 kW |
| — at 690 V rated value | 7.5 kW | 5.5 kW |
| operating frequency | ||
| ● at AC-3 maximum | 15 1/h | 15 1/h |
| ● at AC-3e maximum | 15 1/h | 15 1/h |
| Auxiliary circuit | ||
| number of NC contacts for auxiliary contacts | 0 | |
| number of NO contacts for auxiliary contacts | 0 | 0 |
| number of CO contacts for auxiliary contacts | 0 | 0 |
| product function | ||
| ● ground fault detection No | No | No |
| ● phase failure detection Yes | Yes | Yes |
| trip class | CLASS 10 | CLASS 10 |
| design of the overload release | thermal | thermal |
| maximum short-circuit current breaking capacity (Icu) | ||
| ● at AC at 240 V rated value | 100 kA | 100 kA |
| ● at AC at 400 V rated value 100 kA | 100 kA | 100 kA |
| ● at AC at 500 V rated value 42 kA | 42 kA | 42 kA |
| ● at AC at 690 V rated value 6 kA | 6 kA | 6 kA |
| operating short-circuit current breaking capacity (Ics) at AC |
||
| ● at 240 V rated value 100 kA | 100 kA | 100 kA |
| ● at 400 V rated value 100 kA | 100 kA | 100 kA |
| ● at 500 V rated value 42 kA | 42 kA | 42 kA |
| ● at 690 V rated value 4 kA | 4 kA | 6 kA |
| response value current of instantaneous short-circuit trip unit |
130 A | 104 A |
| UL/CSA ratings | ||
| full-load current (FLA) for 3-phase AC motor | ||
| ● at 480 V rated value 10 A | 10 A | 8 A |
| ● at 600 V rated value 10 A | 10 A | 8 A |
| yielded mechanical performance [hp] | ||
| ● for single-phase AC motor | ||
| — at 110/120 V rated value | 0.5 hp | 0.33 hp |
| — at 230 V rated value | 1.5 hp | 1 hp |
| ● for 3-phase AC motor | ||
| — at 200/208 V rated value | 2 hp | 2 hp |
| — at 220/230 V rated value | 3 hp | 2 hp |
| — at 460/480 V rated value | 5 hp | 5 hp |
| — at 575/600 V rated value | 10 hp | 5 hp |
| Short-circuit protection | ||
| product function short circuit protection | Yes | Yes |
| design of the short-circuit trip | magnetic | magnetic |
| design of the fuse link for IT network for short-circuit protection of the main circuit |
||
| ● at 400 V | gL/gG 50 A | gL/gG 50 A |
| ● at 500 V | gL/gG 40 A | gL/gG 40 A |
| ● at 690 V | gL/gG 40 A | gL/gG 35 A |
| Installation/ mounting/ dimensions | ||
| mounting position | any | any |
| fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| height | 97 mm | 106 mm |
| width | 45 mm | 45 mm |
| depth | 97 mm | 97 mm |
| required spacing | ||
| ● with side-by-side mounting at the side | 0 mm | 0 mm |
| ● for grounded parts at 400 V | ||
| — downwards | 30 mm | 30 mm |
| — upwards | 30 mm | 30 mm |
| — at the side | 9 mm | 9 mm |
| ● for live parts at 400 V | ||
| — downwards | 30 mm | 30 mm |
| — upwards | 30 mm | 30 mm |
| — at the side | 9 mm | 9 mm |
| ● for live parts at 500 V | ||
| — downwards | 30 mm | 30 mm |
| — upwards | 30 mm | 30 mm |
| — at the side | 9 mm | 9 mm |
| ● for grounded parts at 690 V | ||
| — downwards | 50 mm | 50 mm |
| — upwards | 50 mm | 50 mm |
| — backwards | 0 mm | 0 mm |
| — at the side | 30 mm | 30 mm |
| — forwards | 0 mm | 0 mm |
| ● for live parts at 690 V | ||
| — downwards | 50 mm | 50 mm |
| — upwards | 50 mm | 50 mm |
| — backwards | 0 mm | 0 mm |
| — at the side | 30 mm | 30 mm |
| — forwards | 0 mm | 0 mm |
| Connections/ Terminals | ||
| type of electrical connection | ||
| ● for main current circuit | screw-type terminals | spring-loaded terminals |
| arrangement of electrical connectors for main current circuit | Top and bottom | Top and bottom |
| type of connectable conductor cross-sections | ||
| ● for main contacts | ||
| — solid or stranded | 2x (0,75 … 2,5 mm²), 2x 4 mm² | 2x (0,5 … 4 mm²) |
| — finely stranded with core end processing | 2x (0.5 … 1.5 mm²) | 2x (0.5 … 2.5 mm²) |
| — finely stranded without core end processing | 2x (0.75 … 2.5 mm²) | 2x (0.5 … 2.5 mm²) |
| ● at AWG cables for main contacts | 2x (18 … 14), 2x 12 | 2x (20 … 12) |
| tightening torque | ||
| ● for main contacts with screw-type terminals | 0.8 … 1.2 N·m | N/A |
| design of screwdriver shaft | Diameter 5 to 6 mm | Diameter 3 mm |
| size of the screwdriver tip | Pozidriv size 2 | 3,0 x 0,5 mm |
| design of the thread of the connection screw | ||
| ● for main contacts | M3 | N/A |
| Safety related data | ||
| B10 value | ||
| ● with high demand rate according to SN 31920 | 5000 | 5000 |
| proportion of dangerous failures | ||
| ● with low demand rate according to SN 31920 | 50% | 50% |
| ● with high demand rate according to SN 31920 | 50% | 50% |
| failure rate [FIT] | ||
| ● with low demand rate according to SN 31920 | 50 FIT | 51 FIT |
| T1 value for proof test interval or service life according to IEC 61508 |
10 a | 10 a |
| protection class IP on the front according to IEC 60529 |
IP20 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front |
| display version for switching status | Handle | Handle |