LS-400 Series – Digital Laser Sensor – Panasonic Photoelectric Sensors
$ 154.66 – $ 239.14
SKU: N/A
Specification
Item | Specifications | |||
Product Number | LS-H91 | LS-H21 | LS-H91-A | LS-H92 |
Part Number | LS-H91 | LS-H21 | LS-H91-A | LS-H92 |
Regulatory compliance | EMC Directive, RoHS Directive | EMC Directive, RoHS Directive | EMC Directive, RoHS Directive | EMC Directive, RoHS Directive |
Applicable amplifiers | LS-401(P), LS-401(P)-C2, LS-403 | LS-401(P), LS-401(P)-C2, LS-403 | LS-401(P), LS-401(P)-C2, LS-403 | LS-401(P), LS-401(P)-C2, LS-403 |
Sensing range:U-LG mode | 0.1 to 7 m 0.328 to 22.966 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
30 to 1,000 mm 1.181 to 39.370 in | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
0.2 to 30 m 0.656 to 98.425 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:STD mode | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
30 to 500 mm 1.181 to 19.685 in | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
0.2 to 20 m 0.656 to 65.617 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:FAST mode | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
30 to 300 mm 1.181 to 11.811 in | 0.1 to 1 m 0.328 to 3.281 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
0.2 to 10 m 0.656 to 32.808 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Sensing range:H-SP mode | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
30 to 300 mm 1.181 to 11.811 in | 0.1 to 1 m 0.328 to 3.281 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
0.2 to 10 m 0.656 to 32.808 ft (Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
Operation indicator | Orange LED (lights up when the amplifier output is ON) | Orange LED (lights up when the amplifier output is ON) | Orange LED (lights up when the amplifier output is ON) | Orange LED (lights up when the amplifier output is ON) |
Laser emission indicator | Green LED (lights up during laser emission) | Green LED (lights up during laser emission) | Green LED (lights up during laser emission) | Green LED (lights up during laser emission) |
Spot-shape adjuster | – | Multi-turn adjuster | – | – |
Protection | IP40 (IEC) | IP40 (IEC) | IP40 (IEC) | IP40 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ |
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ |
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ |
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | 35 to 85 % RH, Storage: 35 to 85 % RH | 35 to 85 % RH, Storage: 35 to 85 % RH | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face | Incandescent light: 3,000 lx or less at the light-receiving face | Incandescent light: 3,000 lx or less at the light-receiving face | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
1,000 V AC for one min. between all supply terminals connected together and enclosure | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Emitting element:IEC / JIS / GB standards conforming type | Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) |
Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) |
Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) |
Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) |
Emitting element:FDA / IEC / JIS standards conforming type | Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. |
Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. |
Red semiconductor laser, Class 1 (FDA / IEC / JIS) (Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. |
Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. |
Material | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic |
Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic |
Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic |
Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic |
Cable | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. |
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. |
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. |
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. |
Weight | Net weight: 30 g approx Gross weight: 45 g approx |
Net weight: 30 g approx Gross weight: 40 g approx |
Net weight: 30 g approx Gross weight: 45 g approx |
Net weight: 30 g approx Gross weight: 40 g approx |
Accessory | RF-330(Reflector): 1 pc. Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) |
Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) |
RF-330(Reflector): 1 pc. Explanation label: 1 set (Labels are written in Japanese and Chinese for compliance with various standards.) |
RF-230(Reflector): 1 pc. Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details