Specifications

Main
Part Number LC1D475M7C
Product Series TeSys Deca
Product Series TeSys Deca
product type Contactor
product short name LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-1AC
-3
number of poles 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 700 A 40 °C) at <= 440 V AC AC-1 for power circuits
475 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 230V AC 50/60Hz
Additional information
Motor power (kW) 147 kW at 220/240 V AC 50/60 Hz (AC-3)
265 kW at 380/400 V AC 50/60 Hz (AC-3)
280 kW at 415 V AC 50/60 Hz (AC-3)
280 kW at 440 V AC 50/60 Hz (AC-3)
355 kW at 500 V AC 50/60 Hz (AC-3)
335 kW at 660/690 V AC 50 /60 Hz (AC-3)
335 kW at 1000 V AC 50/60 Hz (AC-3)
model LC1D
Loop contact type 3 NO
protection cap None
Conventional thermal current [Ith] 700 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 4200 A at <40 °C – 10 s for power circuit
3200 A at <40 °C – 30 s for power circuit
2400 A at <40 °C – 1 min for power circuit
1500 A at <40 °C – 3 minutes for power circuits
1200 A at <40 °C – 10 minutes for power circuits
Fuses for use with relays 500 A aM at <= 440 V for power circuits
800 A gG at <= 440 V for power circuits
average impedance 0.18 mΩ – Ith 700 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
pollution level 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947
Mechanical life 8 Mcycles
Electrical life 0.4 Mcycles 700 A AC-1 Ue <= 440 V
0.9 Mcycles 460 A AC-3 Ue <= 440 V
0.7 Mcycles 355 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50/60 Hz
Control voltage limit 0.3…0.5 Uc -5…55 °C release 40…400 Hz
0.85…1.1 Uc -5…55 °C run 40…400 Hz
(~50Hz pickup) power consumption (VA) 1100 VA 50 Hz 0.9 20 °C)
1100 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 18VA 50Hz 0.9 20°C)
18VA 60Hz 0.9 20°C)
heat dissipation 18W
action time 100…170 ms open
40…75 ms close
operating frequency 2400 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Tightening torque
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Auxiliary contact type Does not contain
installation method Rail installation
environment
standard IEC 60947-4-1
GB 14048.4
certified product CCC
CE
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (9 gn) conforming to IEC 60068-2-27
high 238 mm
width 233 mm
depth 232 mm
Product Weight 12.5 kg
packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 26.7 cm
Package 1 Width 28.0cm
Package 1 Length 33.0cm
Package 1 Weight 11.62kg
Unit Type of Package 2 PAL
Number of Units in Package 2 8
Package 2 Height 50.0cm
Package 2 Width 60.0cm
Package 2 Length 80.0cm
Package 2 Weight 93.936 kg
contract warranty
Warranty 18 months

 

Weight 12.5 kg
Dimensions 23.2 × 23.3 × 23.8 cm