TeSys Deca – LC1N – 3 Poles (3NO) Contactor, 95A – Schneider Contactors & Reversing Contactors

$ 80.08$ 82.28

SKU: N/A

Specifications

Main
Part Number LC1D95B7C LC1D95CC5C LC1D95E7C LC1D95F7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: 660 V AC
Power circuit: <= 225 V DC 25…400 Hz
Power circuit: 660 V AC
Power circuit: <= 225 V DC 25…400 Hz
Power circuit: 660 V AC
Power circuit: <= 225 V DC 25…400 Hz
Power circuit: 660 V AC
Power circuit: <= 225 V DC 25…400 Hz
Rated operating current [Ie] 125 A 60 °C) at <= 440 V AC AC-1 for power circuit
95 A 60 °C) at <= 440 V AC AC-3 for power circuit
95 A 60 °C) at< = 440 V AC AC-3e for power circuit
125 A 60 °C) at <= 440 V AC AC-1 for power circuit
95 A 60 °C) at <= 440 V AC AC-3 for power circuit
95 A 60 °C) at< = 440 V AC AC-3e for power circuit
125 A 60 °C) at <= 440 V AC AC-1 for power circuit
95 A 60 °C) at <= 440 V AC AC-3 for power circuit
95 A 60 °C) at< = 440 V AC AC-3e for power circuit
125 A 60 °C) at <= 440 V AC AC-1 for power circuit
95 A 60 °C) at <= 440 V AC AC-3 for power circuit
95 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz 36V AC 50Hz 48 V AC 50/60 Hz 110V AC 50/60Hz
Additional information
Motor power (kW) 55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 1000 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC -3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
25 kW at 220/240 V AC 50 /60 Hz (AC-3)
45 kW at 380/400 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 1000 V AC 50/60 Hz (AC-3e)
45 kW at 415/440 V AC 50/60 Hz (AC-3e)
45 kW at 660/690 V AC 50/60 Hz (AC-3e)
25 kW at 220/240 V AC 50/60 Hz (AC-3e)
45 kW at 380/400 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 1000 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC -3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
25 kW at 220/240 V AC 50/60 Hz (AC-3)
45 kW at 380/400 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 1000 V AC 50/60 Hz (AC-3e)
45 kW at 415 /440 V AC 50/60 Hz (AC-3e)
45 kW at 660/690 V AC 50/60 Hz (AC-3e)
25 kW at 220/240 V AC 50/60 Hz (AC-3e )
45 kW at 380/400 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 1000 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC -3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
25 kW at 220/240 V AC 50 /60 Hz (AC-3)
45 kW at 380/400 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 1000 V AC 50/60 Hz (AC-3e)
45 kW at 415/440 V AC 50/60 Hz (AC-3e)
45 kW at 660/690 V AC 50/60 Hz (AC-3e)
25 kW at 220/240 V AC 50/60 Hz (AC-3e)
45 kW at 380/400 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 1000 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC -3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
25 kW at 220/240 V AC 50 /60 Hz (AC-3)
45 kW at 380/400 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 1000 V AC 50/60 Hz (AC-3e)
45 kW at 415/440 V AC 50/60 Hz (AC-3e)
45 kW at 660/690 V AC 50/60 Hz (AC-3e)
25 kW at 220/240 V AC 50/60 Hz (AC-3e)
45 kW at 380/400 V AC 50/60 Hz (AC-3e)
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
protection cap None None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
125 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
125 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
125 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
125 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 135 A at <40 °C – 10 min for power circuit
1100 A at <40 °C – 1 s for power circuit
800 A at <40 °C – 10 s for power circuit
400 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
135 A at <40 °C – 10 min for power circuit
1100 A at <40 °C – 1 s for power circuit
800 A at <40 °C – 10 s for power circuit
400 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
135 A at <40 °C – 10 min for power circuit
1100 A at <40 °C – 1 s for power circuit
800 A at <40 °C – 10 s for power circuit
400 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
135 A at <40 °C – 10 min for power circuit
1100 A at <40 °C – 1 s for power circuit
800 A at <40 °C – 10 s for power circuit
400 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
200 A gG at <= 690 V for type 1 for power circuits
160 A gG for at <= 690 V for type 2 for power circuits
10 A gG for signal circuits according to IEC 60947-5-1
200 A gG at <= 690 V for type 1 for power circuits
160 A gG for at <= 690 V for type 2 for power circuits
10 A gG for signal circuits according to IEC 60947-5-1
200 A gG at <= 690 V for type 1 for power circuits
160 A gG for at <= 690 V for type 2 for power circuits
10 A gG for signal circuits according to IEC 60947-5-1
200 A gG at <= 690 V for type 1 for power circuits
160 A gG for at <= 690 V for type 2 for power circuits
average impedance 0.8 mΩ – Ith 125 A 50 Hz for power circuits 0.8 mΩ – Ith 125 A 50 Hz for power circuits 0.8 mΩ – Ith 125 A 50 Hz for power circuits 0.8 mΩ – Ith 125 A 50 Hz for power circuits
Rated insulation voltage [Ui] Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 4 Mcycles 4 Mcycles 4 Mcycles 4 Mcycles
Electrical life 1.2 Mcycles 95 A AC-3 Ue <= 440 V
1.3 Mcycles 125 A AC-1 Ue <= 440 V
3.2 Mcycles 48 A AC-3 Ue 660/690 V
1.2 Mcycles 95 A AC-3e Ue <= 440 V at
3.2 Mcycles 48 A AC-3e 660/690 V at Ue
1.2 Mcycles 95 A AC-3 Ue <= 440 V
1.3 Mcycles 125 A AC-1 Ue <= 440 V
3.2 Mcycles 48 A AC-3 Ue 660/690 V
1.2 Mcycles 95 A AC-3e Ue <= 440 V at
3.2 Mcycles 48 A AC-3e 660/690 V at Ue
1.2 Mcycles 95 A AC-3 Ue <= 440 V
1.3 Mcycles 125 A AC-1 Ue <= 440 V
3.2 Mcycles 48 A AC-3 Ue 660/690 V
1.2 Mcycles 95 A AC-3e Ue <= 440 V at
3.2 Mcycles 48 A AC-3e 660/690 V at Ue
1.2 Mcycles 95 A AC-3 Ue <= 440 V
1.3 Mcycles 125 A AC-1 Ue <= 440 V
3.2 Mcycles 48 A AC-3 Ue 660/690 V
1.2 Mcycles 95 A AC-3e Ue <= 440 V at
3.2 Mcycles 48 A AC-3e 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz AC at 50 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…55 °C release 50/60 Hz
0.8…1.1 Uc -40…55 °C run 50 Hz
0.85…1.1 Uc -40…55 °C run 60 Hz
0.3…0.6 Uc -40…55 °C release 50 Hz
0.85…1.1 Uc -40…55 °C run 50 Hz
0.3…0.6 Uc -40…55 °C release 50/60 Hz
0.8…1.1 Uc -40…55 °C run 50 Hz
0.85…1.1 Uc -40…55 °C run 60 Hz
0.3…0.6 Uc -40…55 °C release 50/60 Hz
0.8…1.1 Uc -40…55 °C run 50 Hz
0.85…1.1 Uc -40…55 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
200VA 50Hz (0.75 20°C) 245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
20VA 50Hz 0.3 20°C) 26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
heat dissipation 6…10 W at 50/60 Hz 6…10 W at 50 Hz 6…10 W at 50/60 Hz 6…10 W at 50/60 Hz
action time 20…35 ms close
6…20 ms break
20…35 ms close
6…20 ms break
20…35 ms close
6…20 ms break
20…35 ms close
6…20 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power
circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16
mm Type: Flexible cord without wire terminals
Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal
Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals
Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal
Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals
Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power
circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16
mm Type: Flexible cord without wire terminals
Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal
Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals
Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal
Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals
Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power
circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16
mm Type: Flexible cord without wire terminals
Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal
Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals
Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal
Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals
Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power
circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16
mm Type: Flexible cord without wire terminals
Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal
Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals
Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal
Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals
Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals
Tightening torque Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 12 Nm By bolting hexagon 4 mm
Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6
Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted
power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2
: 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2
Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 12 Nm By bolting hexagon 4 mm
Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6
Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted
power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2
: 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2
Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 12 Nm By bolting hexagon 4 mm
Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6
Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted
power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2
: 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2
Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 12 Nm By bolting hexagon 4 mm
Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6
Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted
power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2
: 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method DIN rail installation
base plate installation
DIN rail installation
base plate installation
Chassis mounting
rail installation
DIN rail installation
base plate installation
environment
standard IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27
shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27
shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27
shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27
shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6
high 127 mm 127 mm 127mm 127 mm
width 85 mm 85 mm 85 mm 85 mm
depth 130 mm 130 mm 130 mm 130mm
Product Weight 1.61kg 1.61kg 1.61kg 1.61kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 11.28cm 15.0cm 11.076 cm 11.123 cm
Package 1 Width 15.212 cm 11.1 cm 14.915 cm 15.17cm
Package 1 Length 16.022 cm 15.7cm 15.762 cm 15.92cm
Package 1 Weight 1.571kg 1584.7g 1.581kg 1.579kg
Unit Type of Package 2 CAR CAR CAR CAR
Number of Units in Package 2 5 5 5 5
Package 2 Height 19.2 cm 20.0cm 19.3 cm 19.9 cm
Package 2 Width 29.5cm 30.0cm 29.7 cm 28.7 cm
Package 2 Length 40.2 cm 40.0cm 40.7 cm 39.8 cm
Package 2 Weight 8.271kg 8.38 kg 8.33kg 8.312kg
Unit Type of Package 3 PAL P06 PAL PAL
Number of Units in Package 3 60 60 60 60
Package 3 Height 75.0cm 75.0cm 75.0cm 75.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 104.016kg 110.56kg 104.7kg 104.388 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number LC1D95M7C LC1D95Q7C
Product Series TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca
product type Contactor Contactor
product short name LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P
Rated working voltage [Ue] Power circuit: 660 V AC
Power circuit: <= 225 V DC 25…400 Hz
Power circuit: 660 V AC
Power circuit: <= 225 V DC 25…400 Hz
Rated operating current [Ie] 125 A 60 °C) at <= 440 V AC AC-1 for power circuit
95 A 60 °C) at <= 440 V AC AC-3 for power circuit
95 A 60 °C) at< = 440 V AC AC-3e for power circuit
125 A 60 °C) at <= 440 V AC AC-1 for power circuit
95 A 60 °C) at <= 440 V AC AC-3 for power circuit
95 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 230V AC 50/60Hz 380 V AC 50/60 Hz
Additional information
Motor power (kW) 55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 1000 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC -3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
25 kW at 220/240 V AC 50 /60 Hz (AC-3)
45 kW at 380/400 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 1000 V AC 50/60 Hz (AC-3e)
45 kW at 415/440 V AC 50/60 Hz (AC-3e)
45 kW at 660/690 V AC 50/60 Hz (AC-3e)
25 kW at 220/240 V AC 50/60 Hz (AC-3e)
45 kW at 380/400 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 1000 V AC 50/60 Hz (AC-3)
45 kW at 415/440 V AC 50/60 Hz (AC -3)
45 kW at 660/690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
25 kW at 220/240 V AC 50 /60 Hz (AC-3)
45 kW at 380/400 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 1000 V AC 50/60 Hz (AC-3e)
45 kW at 415/440 V AC 50/60 Hz (AC-3e)
45 kW at 660/690 V AC 50/60 Hz (AC-3e)
25 kW at 220/240 V AC 50/60 Hz (AC-3e)
45 kW at 380/400 V AC 50/60 Hz (AC-3e)
model LC1D LC1D
Loop contact type 3 NO 3 NO
protection cap None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
125 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
125 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 135 A at <40 °C – 10 min for power circuit
1100 A at <40 °C – 1 s for power circuit
800 A at <40 °C – 10 s for power circuit
400 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
135 A at <40 °C – 10 min for power circuit
1100 A at <40 °C – 1 s for power circuit
800 A at <40 °C – 10 s for power circuit
400 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
200 A gG at <= 690 V for type 1 for power circuits
160 A gG for at <= 690 V for type 2 for power circuits
10 A gG for signal circuits according to IEC 60947-5-1
200 A gG at <= 690 V for type 1 for power circuits
160 A gG for at <= 690 V for type 2 for power circuits
average impedance 0.8 mΩ – Ith 125 A 50 Hz for power circuits 0.8 mΩ – Ith 125 A 50 Hz for power circuits
Rated insulation voltage [Ui] Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III III
pollution level 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 4 Mcycles 4 Mcycles
Electrical life 1.2 Mcycles 95 A AC-3 Ue <= 440 V
1.3 Mcycles 125 A AC-1 Ue <= 440 V
3.2 Mcycles 48 A AC-3 Ue 660/690 V
1.2 Mcycles 95 A AC-3e Ue <= 440 V at
3.2 Mcycles 48 A AC-3e 660/690 V at Ue
1.2 Mcycles 95 A AC-3 Ue <= 440 V
1.3 Mcycles 125 A AC-1 Ue <= 440 V
3.2 Mcycles 48 A AC-3 Ue 660/690 V
1.2 Mcycles 95 A AC-3e Ue <= 440 V at
3.2 Mcycles 48 A AC-3e 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…55 °C release 50/60 Hz
0.8…1.1 Uc -40…55 °C run 50 Hz
0.85…1.1 Uc -40…55 °C run 60 Hz
0.3…0.6 Uc -40…55 °C release 50/60 Hz
0.8…1.1 Uc -40…55 °C run 50 Hz
0.85…1.1 Uc -40…55 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
heat dissipation 6…10 W at 50/60 Hz 6…10 W at 50/60 Hz
action time 20…35 ms close
6…20 ms break
20…35 ms close
6…20 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power
circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16
mm Type: Flexible cord without wire terminals
Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal
Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals
Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal
Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals
Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals
Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power
circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16
mm Type: Flexible cord without wire terminals
Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal
Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals
Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal
Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals
Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals
Tightening torque Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 12 Nm By bolting hexagon 4 mm
Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6
Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted
power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2
: 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2
Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 12 Nm By bolting hexagon 4 mm
Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6
Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted
power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2
: 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
environment
standard IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27
shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27
shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6
high 127 mm 127mm
width 85 mm 85 mm
depth 130mm 130mm
Product Weight 1.61kg 1.61kg
packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 11.5cm 11.5cm
Package 1 Width 14.7 cm 14.5cm
Package 1 Length 15.5cm 15.4 cm
Package 1 Weight 1.588 kg 1.628 kg
Unit Type of Package 2 CAR CAR
Number of Units in Package 2 5 5
Package 2 Height 20.4cm 19.7cm
Package 2 Width 28.9 cm 28.9 cm
Package 2 Length 39.6 cm 39.7 cm
Package 2 Weight 8.366 kg 8.323kg
Unit Type of Package 3 PAL PAL
Number of Units in Package 3 60 60
Package 3 Height 75.0cm 75.0cm
Package 3 Width 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm
Package 3 Weight 105.396kg 99.156 kg
contract warranty
Warranty 18 months 18 months

 

Weight N/A
Dimensions N/A