TeSys Deca – LC1N – 3 Poles (3NO) Contactor, 95A – Schneider Contactors & Reversing Contactors
$ 80.08 – $ 82.28
SKU: N/A
Specifications
Main | ||||
Part Number | LC1D95B7C | LC1D95CC5C | LC1D95E7C | LC1D95F7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz |
Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz |
Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz |
Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz |
Rated operating current [Ie] | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit |
125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit |
125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit |
125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 24 V AC 50/60 Hz | 36V AC 50Hz | 48 V AC 50/60 Hz | 110V AC 50/60Hz |
Additional information | ||||
Motor power (kW) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 25 kW at 220/240 V AC 50/60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415 /440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e ) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
average impedance | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 4 Mcycles | 4 Mcycles | 4 Mcycles | 4 Mcycles |
Electrical life | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue |
1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue |
1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue |
1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50 Hz 0.85…1.1 Uc -40…55 °C run 50 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
200VA 50Hz (0.75 20°C) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
20VA 50Hz 0.3 20°C) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz |
action time | 20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
DIN rail installation base plate installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
environment | ||||
standard | IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
high | 127 mm | 127 mm | 127mm | 127 mm |
width | 85 mm | 85 mm | 85 mm | 85 mm |
depth | 130 mm | 130 mm | 130 mm | 130mm |
Product Weight | 1.61kg | 1.61kg | 1.61kg | 1.61kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 11.28cm | 15.0cm | 11.076 cm | 11.123 cm |
Package 1 Width | 15.212 cm | 11.1 cm | 14.915 cm | 15.17cm |
Package 1 Length | 16.022 cm | 15.7cm | 15.762 cm | 15.92cm |
Package 1 Weight | 1.571kg | 1584.7g | 1.581kg | 1.579kg |
Unit Type of Package 2 | CAR | CAR | CAR | CAR |
Number of Units in Package 2 | 5 | 5 | 5 | 5 |
Package 2 Height | 19.2 cm | 20.0cm | 19.3 cm | 19.9 cm |
Package 2 Width | 29.5cm | 30.0cm | 29.7 cm | 28.7 cm |
Package 2 Length | 40.2 cm | 40.0cm | 40.7 cm | 39.8 cm |
Package 2 Weight | 8.271kg | 8.38 kg | 8.33kg | 8.312kg |
Unit Type of Package 3 | PAL | P06 | PAL | PAL |
Number of Units in Package 3 | 60 | 60 | 60 | 60 |
Package 3 Height | 75.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 104.016kg | 110.56kg | 104.7kg | 104.388 kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||
Part Number | LC1D95M7C | LC1D95Q7C |
Product Series | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor |
product short name | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P |
Rated working voltage [Ue] | Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz |
Power circuit: 660 V AC Power circuit: <= 225 V DC 25…400 Hz |
Rated operating current [Ie] | 125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit |
125 A 60 °C) at <= 440 V AC AC-1 for power circuit 95 A 60 °C) at <= 440 V AC AC-3 for power circuit 95 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230V AC 50/60Hz | 380 V AC 50/60 Hz |
Additional information | ||
Motor power (kW) | 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) |
55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 45 kW at 415/440 V AC 50/60 Hz (AC -3) 45 kW at 660/690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220/240 V AC 50 /60 Hz (AC-3) 45 kW at 380/400 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 1000 V AC 50/60 Hz (AC-3e) 45 kW at 415/440 V AC 50/60 Hz (AC-3e) 45 kW at 660/690 V AC 50/60 Hz (AC-3e) 25 kW at 220/240 V AC 50/60 Hz (AC-3e) 45 kW at 380/400 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO |
protection cap | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 125 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
135 A at <40 °C – 10 min for power circuit 1100 A at <40 °C – 1 s for power circuit 800 A at <40 °C – 10 s for power circuit 400 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
10 A gG for signal circuits according to IEC 60947-5-1 200 A gG at <= 690 V for type 1 for power circuits 160 A gG for at <= 690 V for type 2 for power circuits |
average impedance | 0.8 mΩ – Ith 125 A 50 Hz for power circuits | 0.8 mΩ – Ith 125 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III |
pollution level | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 4 Mcycles | 4 Mcycles |
Electrical life | 1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue |
1.2 Mcycles 95 A AC-3 Ue <= 440 V 1.3 Mcycles 125 A AC-1 Ue <= 440 V 3.2 Mcycles 48 A AC-3 Ue 660/690 V 1.2 Mcycles 95 A AC-3e Ue <= 440 V at 3.2 Mcycles 48 A AC-3e 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
0.3…0.6 Uc -40…55 °C release 50/60 Hz 0.8…1.1 Uc -40…55 °C run 50 Hz 0.85…1.1 Uc -40…55 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
26 VA 50 Hz 0.3 20 °C) 26 VA 60 Hz 0.3 20 °C) |
heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz |
action time | 20…35 ms close 6…20 ms break |
20…35 ms close 6…20 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Control circuit: Bolt tight 1…4 mm² Cable option: Flexible without wire terminals Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible with wire terminals Control circuit: Bolt tight 1…4 mm² Cable option: solid without wire terminals Power circuit: busbar terminal Cable option: solid busbar cross-section: 3 x 16 mm Type: Flexible cord without wire terminals Power circuit: Terminal 4…25 mm² Lug O.D. Ø: 17 mm Cable selection: Flexible cord without wire terminal Power circuit: Terminal 4…50 mm² Lug O.D. Ø: 17 mm Cable option: flexible cord with wire terminals Power circuit: terminal 4…16 mm² Lug outer diameter Ø: 17 mm Cable option: flexible cord with wire terminal Power circuit: terminal 4…50 mm² Lug outer diameter Ø: 17 mm Cable selection: solid without wire terminals Power circuit: terminal 4…25 mm² Cable selection: solid without wire terminals |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 12 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 12 Nm By bolting hexagon 4 mm Power circuit: 12 Nm By terminal hexagon 10 mm Screw: M6 Power circuit: 12 Nm By terminal with screwdriver Ø 8 Slotted power circuit: 12 Nm By screw Control circuit with screwdriver pozidriv No 2 : 1.2 Nm Fasten via screwdriver with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
environment | ||
standard | IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
Shock resistance contact opening (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms contact closed (10 gn) conforming to IEC 60068-2-27 shock resistance closed (3 gn (5…300 Hz)) conforming to IEC 60068-2-6 |
high | 127 mm | 127mm |
width | 85 mm | 85 mm |
depth | 130mm | 130mm |
Product Weight | 1.61kg | 1.61kg |
packaging unit | ||
Unit Type of Package 1 | PCE | PCE |
Number of Units in Package 1 | 1 | 1 |
Package 1 Height | 11.5cm | 11.5cm |
Package 1 Width | 14.7 cm | 14.5cm |
Package 1 Length | 15.5cm | 15.4 cm |
Package 1 Weight | 1.588 kg | 1.628 kg |
Unit Type of Package 2 | CAR | CAR |
Number of Units in Package 2 | 5 | 5 |
Package 2 Height | 20.4cm | 19.7cm |
Package 2 Width | 28.9 cm | 28.9 cm |
Package 2 Length | 39.6 cm | 39.7 cm |
Package 2 Weight | 8.366 kg | 8.323kg |
Unit Type of Package 3 | PAL | PAL |
Number of Units in Package 3 | 60 | 60 |
Package 3 Height | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm |
Package 3 Weight | 105.396kg | 99.156 kg |
contract warranty | ||
Warranty | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details