TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 40A – Schneider Contactors & Reversing Contactors

$ 32.34$ 120.78

SKU: N/A

Specifications

Main
Part Number LC1D40AB7C LC1D40ACC7C LC1D40AE7C LC1D40AF7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz 36 V AC 50/60 Hz 48 V AC 50/60 Hz 110V AC 50/60Hz
Additional information
Motor power (kW) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
protection cap None None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
average impedance 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 6 Mcycles 6 Mcycles 6 Mcycles 6 Mcycles
Electrical life 1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
heat dissipation 4…5 W at 50/60 Hz 4…5 W at 50/60 Hz 4…5 W at 50/60 Hz 4…5 W at 50/60 Hz
action time 4…19 ms open
12…26 ms close
4…19 ms open
12…26 ms close
4…19 ms open
12…26 ms close
4…19 ms open
12…26 ms close
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal
Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals
Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals
Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option
: flexible wire with wire terminal Terminal
Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit:
screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal
Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal
Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals
Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals
Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option
: flexible wire with wire terminal Terminal
Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit:
screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal
Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal
Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals
Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals
Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option
: flexible wire with wire terminal Terminal
Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit:
screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal
Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal
Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals
Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals
Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option
: flexible wire with wire terminal Terminal
Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit:
screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal
Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal
Tightening torque Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat
control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw
Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm
Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6
power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm
control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat
control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw
Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm
Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6
power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm
control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat
control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw
Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm
Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6
power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm
control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat
control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw
Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm
Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6
power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm
control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
Chassis mounting
rail installation
DIN rail installation
base plate installation
environment
standard GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
high 122mm 122mm 122mm 122mm
width 55mm 55mm 55mm 55mm
depth 120 mm 120 mm 120 mm 120 mm
Product Weight 0.85 kg 0.85 kg 0.85 kg 0.85 kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 6.366 cm 6.271 cm 6.245 cm 6.046 cm
Package 1 Width 13.405 cm 13.848 cm 13.747 cm 13.663 cm
Package 1 Length 15.071 cm 15.315 cm 15.707 cm 15.316 cm
Package 1 Weight 940.0g 931.0g 950.0g 950.0g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 10 10 10 10
Package 2 Height 15.0cm 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 9.86kg 9.841 kg 9.91kg 9.881kg
Unit Type of Package 3 PAL PAL PAL PAL
Number of Units in Package 3 160 160 160 160
Package 3 Height 75.0cm 75.0cm 75.0cm 75.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 160.864 kg 160.864 kg 160.864 kg 160.864 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number LC1D40AM7 LC1D40AM7C LC1D40AQ7C LC1D40B7C
Product Series TeSys
TeSys Deca
TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 60 A 60 °C) at <= 440 V AC AC-1 for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuit
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 230V AC 50/60Hz 230V AC 50/60Hz 380 V AC 50/60 Hz 24 V AC 50/60 Hz
Additional information
Motor power (kW) 18.5 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 220…230 V AC 50/60 Hz (AC-3)
22 kW at 415.. .440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660…690 V AC 50/60 Hz (AC-3 )
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 220…230 V AC 50/60 Hz (AC-3e)
22 kW at 415…440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660…690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
Motor Power 5 hp at 230/240 V AC 50/60 Hz for 1-phase motors
10 hp at 230/240 V AC 50/60 Hz for 3-phase motors
30 hp at 575/600 V AC 50/60 Hz For 3-phase motors
10 hp at 200/208 V AC 50/60 Hz For 3-phase motors
3 hp at 115 V AC 50/60 Hz For 1-phase motors
30 hp at 460/480 V AC 50/ 60 Hz for 3-phase motors
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
Contactor Compatibility Features M2
protection cap Bring None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
Rated making capacity [Irms] 140 A AC for signal circuits according to IEC 60947-5-1
250 A DC for signal circuits according to IEC 60947-5-1
800 A at 440 V for power circuits according to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
320 A at <40 °C – 10 s for power circuit
720 A at <40 °C – 1 s for power circuit
72 A at <40 °C – 10 min for power circuit
165 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
average impedance 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits
power consumption per pole 2.4W AC-3
5.4W AC-1
2.4W AC-3e
Rated insulation voltage [Ui] Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signal circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 6 Mcycles 6 Mcycles 6 Mcycles 6 Mcycles
Electrical life 1.4 Mcycles 60 A AC-1 <= 440 V at Ue
1.5 Mcycles 40 A AC-3 Ue <= 440 V
1.5 Mcycles 40 A AC-3e <= 440 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz standard AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…70 °C Release AC 50/60 Hz
0.8…1.1 Uc -40…60 °C Run AC 50 Hz
0.85…1.1 Uc -40…60 °C Run AC 60 Hz
1…1.1 Uc 60…70 °C Operation AC 50/60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
140 VA 60 Hz 0.75 20 °C)
160 VA 50 Hz 0.75 20 °C)
245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
13 VA 60 Hz 0.3 20 °C)
15 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
26 VA 50 Hz 0.3 20 °C)
heat dissipation 4…5 W at 50/60 Hz 4…5 W at 50/60 Hz 4…5 W at 50/60 Hz 6…10 W at 50/60 Hz
action time 4…19 ms open
12…26 ms close
4…19 ms open
12…26 ms close
4…19 ms open
12…26 ms close
20…26 ms close
8…12 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: screw-on2 1…2.5 mm² Cable option: flexible cord with wire terminal
Control circuit: screw-on1 1…4 mm² Cable option: flexible cable without cable terminal
Control circuit: screw-on2 1…4 mm² cable option: flexible without cable terminals
Control circuit: screw-on1 1…4 mm² cable option: flexible cable with cable terminal
control circuit: screw-on1 1…4 mm² cable option : Hard wire without wire terminal
Control circuit: Bolt fastening2 1…4 mm² Cable option: Hard wire without wire terminal
Power circuit: EverLink BTR terminal1 1…35 mm² Cable option: Flexible wire without Wire terminal
power circuit: EverLink BTR terminal 2 1…25 mm² Cable selection: flexible cord without wire terminal Power
circuit: EverLink BTR terminal 1 1…35 mm² Cable selection: flexible cord with wire terminal
power circuit : EverLink BTR terminal block 2 1…25 mm² Cable option: flexible wire with wire terminal Power
circuit: EverLink BTR terminal block 1 1…35 mm² Cable option: rigid without wire terminal
Power circuit: EverLink BTR terminal block 2 1…25 mm² Cable option: solid without cable terminals
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal
Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals
Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals
Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option
: flexible wire with wire terminal Terminal
Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit:
screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal
Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal
Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals
Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals
Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option
: flexible wire with wire terminal Terminal
Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit:
screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal
Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal
Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals
Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power
circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal
Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal
Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power
circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal
Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal
Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal
Tightening torque Control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screwdriver No. 2 Phillips screw
power circuit: 8 Nm via EverLink BTR terminal block cable 25…35 mm² hexagonal 4 mm
power circuit : 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagonal 4 mm
control circuit: 1.7 Nm via screwdriver pozidriv No 2
power circuit: 2.5 Nm via screwdriver pozidriv No 2
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat
control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw
Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm
Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6
power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm
control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat
control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw
Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm
Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6
power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm
control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2
Control circuit: 1.7 Nm via screwdriver No. 2 Phillips screw power
supply circuit: 2.5 Nm via screwdriver Ø 6…8 mm slotted
control circuit: 2.5 Nm via screwdriver Ø 6 flat
power supply Circuit: 1.7 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5
Power circuit: 2.5 Nm Via cable connector with screwdriver No. 2 Phillips screw: M5
2.5 Nm
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz 25…400Hz
Minimum switching voltage 17 V for signal return
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
DIN rail installation
base plate installation
DIN rail installation
base plate installation
Chassis mounting
rail installation
environment
standard CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
certified product CCC
GOST
UL
CSA
CCC
CE
UKCA
CCC
CE
UKCA
CCC
UKCA
CE
IP protection class IP20 front panel complies with screwed IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
IP2x front panel for main circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
climate tolerance Complies with IACS E10 for exposure to hot flashes
Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes
ambient air temperature -40…60 °C
60…70 °C with derating
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 0…3000m 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
flame retardant V1 complies with UL 94
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz))
shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance
with contacts closed (15 gn (11ms))
Shock performance Contact opening (10 gn (11ms))
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27
high 122mm 122mm 122mm 127mm
width 55mm 55mm 55mm 75 mm
depth 120 mm 120 mm 120 mm 119mm
Product Weight 0.85 kg 0.85 kg 0.85 kg 1.4kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 6.2 cm 6.27cm 6.22cm 14.2 cm
Package 1 Width 13.5cm 13.49 cm 13.49 cm 11.1 cm
Package 1 Length 15.2 cm 15.07cm 15.05cm 14.5cm
Package 1 Weight 915.0g 973.89g 982.09g 1328.54g
Unit Type of Package 2 S02 S02 S02 S03
Number of Units in Package 2 10 10 10 12
Package 2 Height 15.0cm 15.0cm 15.0cm 30.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 9.776 kg 9.871kg 9.97kg 16.5 kg
Unit Type of Package 3 P06 PAL PAL P06
Number of Units in Package 3 160 160 160 96
Package 3 Height 77.0cm 75.0cm 75.0cm 75.0cm
Package 3 Width 80.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 60.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 164.9 kg 160.864 kg 160.864 kg 142.0 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Main
Part Number LC1D40F7C LC1D40Q7C LC1D40M7C
Product Series TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor
product short name LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
AC-4
AC-1
AC-3
AC-3e
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
40 A 60 °C) at <= 440 V AC AC-3 for power circuits
60 A 60 °C) at <= 440 V AC AC-1 for power circuits
40 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 110V AC 50/60Hz 380 V AC 50/60 Hz 230V AC 50/60Hz
Additional information
Motor power (kW) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at… at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC -3e)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
11 kW at 220/240 V AC 50/60 Hz (AC-3)
22 kW at 415/440 V AC 50/60 Hz (AC-3)
30 kW at 660/690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380/400 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
11 kW at… at 220/240 V AC 50/60 Hz (AC-3e)
22 kW at 415/440 V AC 50/60 Hz (AC-3e)
30 kW at 660/690 V AC 50/60 Hz (AC -3e)
model LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO
protection cap None None None
Conventional thermal current [Ith] 10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
60 A at <60 °C for power circuits
Rated short-time withstand current [Icw] 240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
240 A at <40 °C – 10 s for power circuit
380 A at <40 °C – 1 s for power circuit
50 A at <40 °C – 10 min for power circuit
120 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
10 A gG for signal circuits according to IEC 60947-5-1
80 A gG at <= 690 V for power circuits type 1
80 A gG for power circuits for type 2 at <= 690 V
average impedance 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits 1.5 mΩ – Ith 60 A 50 Hz for power circuits
Rated insulation voltage [Ui] Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947 6 kV according to IEC 60947 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 6 Mcycles 6 Mcycles 6 Mcycles
Electrical life 1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
1.6 Mcycles 40 A AC-3 Ue <= 440 V
1.6 Mcycles 33 A AC-3 Ue 660/690 V
1.4 Mcycles 60 A AC-1 Ue <= 440 V
1.6 Mcycles 40 A AC-3e Ue <= 440 V
at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module No built-in surge suppression module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
245 VA 60 Hz 0.75 20 °C)
245 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 26 VA 60 Hz 0.3 20 °C)
26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
26 VA 50 Hz 0.3 20 °C)
26 VA 60 Hz 0.3 20 °C)
26 VA 50 Hz 0.3 20 °C)
heat dissipation 6…10 W at 50/60 Hz 6…10 W at 50/60 Hz 6…10 W at 50/60 Hz
action time 20…26 ms close
8…12 ms break
20…26 ms close
8…12 ms break
20…26 ms close
8…12 ms break
operating frequency 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C 3600 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals
Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power
circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal
Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal
Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power
circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal
Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal
Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals
Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power
circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal
Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal
Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power
circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal
Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal
Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals
Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power
circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal
Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal
Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power
circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal
Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal
Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal
Tightening torque Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5
Power circuit: 5 Nm Via cable connector with screwdriver No 2 Phillips screw: M5
Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5
Power circuit: 5 Nm Via cable connector with screwdriver No 2 Phillips screw: M5
Control circuit: 1.2 Nm via screwdriver Ø 6 flat
control circuit: 1.2 Nm via screwdriver No 2 Phillips screw
Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted
power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5
Power circuit: 5 Nm Via cable connector with screwdriver No 2 Phillips screw: M5
Auxiliary contact type 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
1 NO + 1 NC 1 NO + 1 NC
Signal loop frequency 25…400Hz 25…400Hz 25…400Hz
Minimum switching current [Imin] 5 mA for signal loop 5 mA for signal loop 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops > 10 MΩ for signal loops > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
Chassis mounting
rail installation
DIN rail installation
base plate installation
environment
standard IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
certified product CCC
UKCA
CE
CCC
UKCA
CE
CCC
UKCA
CE
IP protection class IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for main circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27
high 127mm 127mm 127mm
width 75 mm 75 mm 75 mm
depth 119 mm 119mm 119mm
Product Weight 1.4kg 1.4kg 1.4kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 10.23cm 10.437 cm 10.1 cm
Package 1 Width 13.936 cm 13.892 cm 14.2 cm
Package 1 Length 14.167 cm 14.154 cm 14.45cm
Package 1 Weight 1.321kg 1.321kg 1.331kg
Unit Type of Package 2 S03 S03 S03
Number of Units in Package 2 12 12 12
Package 2 Height 30.0cm 30.0cm 30.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm
Package 2 Weight 16.431kg 16.48kg 16.591kg
Unit Type of Package 3 P06 P06 P06
Number of Units in Package 3 96 96 96
Package 3 Height 75.0cm 75.0cm 75.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm
Package 3 Weight 141.448kg 141.84 kg 142.728kg
contract warranty
Warranty 18 months 18 months 18 months

 

 

Weight N/A
Dimensions N/A

Related products