TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 9A – Schneider Contactors & Reversing Contactors
$ 14.74 – $ 44.22
SKU: N/A
Specifications
Main | ||||
Part Number | LC1D09M7 | LC1D096M7C | LC1D09B7C | LC1D09BDC |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-3 AC-1 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at< = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230V AC 50/60Hz | 230V AC 50/60Hz | 24 V AC 50/60 Hz | 24 V DC |
Additional information | ||||
Motor power (kW) | 2.2 kW at 220…230 V AC 50/60 Hz (AC-3) 4 kW at 380…400 V AC 50/60 Hz (AC-3) 4 kW at 415.. .440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660…690 V AC 50/60 Hz (AC-3 ) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 2.2 kW at 220…230 V AC 50/60 Hz (AC-3e) 4 kW at 380…400 V AC 50/60 Hz (AC-3e) 4 kW at 415…440 V AC 50/60 Hz (AC-3e) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 5.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
Motor Power | 1 hp at 230/240 V AC 50/60 Hz for 1-phase motors 2 hp at 200/208 V AC 50/60 Hz for 3-phase motors 2 hp at 230/240 V AC 50/60 Hz For 3-phase motors 5 hp at 460/480 V AC 50/60 Hz For 3-phase motors 7.5 hp at 575/600 V AC 50/60 Hz For 3-phase motors 0.33 hp at 115 V AC 50/ 60 Hz for 1-phase motors |
N/A | ||
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
Contactor Compatibility Features | M2 | N/A | ||
protection cap | Bring | None | None | None |
Conventional thermal current [Ith] | 25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
Rated making capacity [Irms] | 250 A at 440 V for power circuits according to IEC 60947 140 A AC for signal circuits according to IEC 60947-5-1 250 A DC for signal circuits according to IEC 60947-5-1 |
N/A | ||
Rated breaking capacity | 250 A at 440 V for power circuits conforming to IEC 60947 | |||
Rated short-time withstand current [Icw] | 105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop |
power consumption per pole | 1.56W AC-1 0.2W AC-3 0.2W AC-3e |
N/A | ||
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signaling circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 15 Mcycles | 15 Mcycles | 15 Mcycles | 30 Mcycles |
Electrical life | 0.6 Mcycles 25 A AC-1 Ue <= 440 V 2 Mcycles 9 A AC-3 Ue <= 440 V 2 Mcycles 9 A AC-3e Ue <= 440 V |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz standard | AC at 50/60 Hz | AC at 50/60 Hz | DC standard |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | Built-in bidirectional peak current limiting diode |
Control voltage limit | 0.3…0.6 Uc -40…70 °C Release AC 50/60 Hz 0.8…1.1 Uc -40…60 °C Run AC 50 Hz 0.85…1.1 Uc -40…60 °C Run AC 60 Hz 1…1.1 Uc 60…70 °C Operation AC 50/60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.1…0.25 Uc -40…60 °C release 0.7…1.25 Uc -40…60 °C run |
(~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
N/A |
(~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
|
heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz | |
action time | 12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
55 ms to close, 20 ms to break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: Bolt-on1 1…4 mm² Cable option: Flexible without wire terminals Power circuit: Bolt-on2 1…4 mm² Cable option: Flexible without wire terminal Power circuit: Bolt-on 1 1…4 mm² cable option: flexible cord with cable terminals Power circuit: screw-fastened2 1…2.5 mm² cable option: flexible cable with cable terminal Power circuit: screw-fastened1 cable option 1…4 mm² : Hard wire without wire terminal Power circuit: Bolt fastening2 1…4 mm² Cable selection: Hard wire without wire terminal Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible wire without wire wire Wire terminal control circuit: screw-on2 1…4 mm² cable selection: flexible without wire terminal control circuit: screw-on1 1…4 mm² cable selection: flexible with wire terminal control circuit: screw-tight Solid2 1…2.5 mm² Cable option: flexible cable with wire terminals Control circuit: screw-on1 1…4 mm² Cable option: solid without cable terminals Control circuit: screw-on2 1…4 mm² cable Type selection: hard wire without wire terminal |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Tightening torque | Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for tightening Phillips screw Control circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts Power supply circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade via cable connector: M3.5 Power circuit : 1.7 Nm Screwdriver No. 2 Phillips screw via cable connector Screw: M3.5 Power circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 Control circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
environment | ||||
standard | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | BV LROS (Lloyds register of shipping) UL GOST GL DNV CSA RINA CCC UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP20 front panel conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
climate tolerance | Complies with IACS E10 for exposure to hot flashes Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes |
N/A | ||
ambient air temperature | -40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 0…3000m | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
flame retardant | V1 complies with UL 94 | N/A | ||
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts open (10 gn (11ms)) shock resistance Performance Contact closed state (15 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 77 mm | 77 mm | 77 mm | 77 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 86 mm | 86 mm | 86 mm | 95 mm |
Product Weight | 0.32kg | 0.32kg | 0.32kg | 0.48 kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5.0cm | 8.0cm | 5.138cm | 5.33cm |
Package 1 Width | 9.2cm | 9.3cm | 7.87cm | 7.83cm |
Package 1 Length | 11.5cm | 5.2cm | 9.433cm | 10.26cm |
Package 1 Weight | 346.0g | 334.42g | 350.0g | 523.0g |
Unit Type of Package 2 | S02 | CAR | S02 | S02 |
Number of Units in Package 2 | 20 | 24 | 24 | 21 |
Package 2 Height | 15.0cm | 30.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 40.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 15.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 7.236kg | 8.076kg | 8.891kg | 11.5kg |
Unit Type of Package 3 | P06 | PAL | PAL | PAL |
Number of Units in Package 3 | 320 | 384 | 384 | 336 |
Package 3 Height | 75cm | 60cm | 60cm | 60cm |
Package 3 Width | 60cm | 80cm | 80cm | 80cm |
Package 3 Length | 80cm | 75cm | 75cm | 75cm |
Package 3 Weight | 123.5kg | 128.616kg | 154.785kg | 181.444kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D09BL | LC1D09CC7C | LC1D09E7C | LC1D09F7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-3 AC-1 AC-4 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at< = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 24 V DC | 36 V AC 50/60 Hz | 48 V AC 50/60 Hz | 110V AC 50/60Hz |
Additional information | ||||
Motor power (kW) | 2.2 kW at 220…230 V AC 50/60 Hz (AC-3) 4 kW at 380…400 V AC 50/60 Hz (AC-3) 4 kW at 415.. .440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660…690 V AC 50/60 Hz (AC-3 ) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 2.2 kW at 220…230 V AC 50/60 Hz (AC-3e) 4 kW at 380…400 V AC 50/60 Hz (AC-3e) 4 kW at 415…440 V AC 50/60 Hz (AC-3e) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 5.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
Motor Power | 1 hp at 230/240 V AC 50/60 Hz for 1-phase motors 2 hp at 200/208 V AC 50/60 Hz for 3-phase motors 2 hp at 230/240 V AC 50/60 Hz For 3-phase motors 5 hp at 460/480 V AC 50/60 Hz For 3-phase motors 7.5 hp at 575/600 V AC 50/60 Hz For 3-phase motors 0.33 hp at 115 V AC 50/ 60 Hz for 1-phase motors |
N/A | ||
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
Contactor Compatibility Features | M5 | N/A | ||
protection cap | Bring | None | None | None |
Conventional thermal current [Ith] | 25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
Rated making capacity [Irms] | 250 A at 440 V for power circuits according to IEC 60947 140 A AC for signal circuits according to IEC 60947-5-1 250 A DC for signal circuits according to IEC 60947-5-1 |
N/A | ||
Rated breaking capacity | 250 A at 440 V for power circuits conforming to IEC 60947 | |||
Rated short-time withstand current [Icw] | 105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop |
power consumption per pole | 1.56W AC-1 0.2W AC-3 0.2W AC-3e |
N/A | ||
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signaling circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 30 Mcycles | 15 Mcycles | 15 Mcycles | 15 Mcycles |
Electrical life | 0.6 Mcycles 25 A AC-1 Ue <= 440 V 2 Mcycles 9 A AC-3 Ue <= 440 V 2 Mcycles 9 A AC-3e Ue <= 440 V |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
Control loop characteristics | DC low power consumption | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | Built-in bidirectional peak current limiting diode | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.1…0.3 Uc -40…70 °C release DC 0.8…1.25 Uc -40…60 °C run DC 1…1.25 Uc 60…70 °C run DC |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
Surge power (W) | 2.4W (20°C) | N/A | ||
Holding power consumption(W) | 2.4 W at 20 °C | |||
action time | 65.45…88.55 ms closed 20…30 ms open |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
time constant | 40ms | N/A | ||
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: Bolt-on1 1…4 mm² Cable option: Flexible without wire terminals Power circuit: Bolt-on2 1…4 mm² Cable option: Flexible without wire terminal Power circuit: Bolt-on 1 1…4 mm² cable option: flexible cord with cable terminals Power circuit: screw-fastened2 1…2.5 mm² cable option: flexible cable with cable terminal Power circuit: screw-fastened1 cable option 1…4 mm² : Hard wire without wire terminal Power circuit: Bolt fastening2 1…4 mm² Cable selection: Hard wire without wire terminal Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible wire without wire wire Wire terminal control circuit: screw-on2 1…4 mm² cable selection: flexible without wire terminal control circuit: screw-on1 1…4 mm² cable selection: flexible with wire terminal control circuit: screw-tight Solid2 1…2.5 mm² Cable option: flexible cable with wire terminals Control circuit: screw-on1 1…4 mm² Cable option: solid without cable terminals Control circuit: screw-on2 1…4 mm² cable Type selection: hard wire without wire terminal |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Tightening torque | Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for tightening Phillips screw Control circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts Power supply circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
DIN rail installation base plate installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
environment | ||||
standard | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | GL UL LROS (Lloyds register of shipping) CCC RINA BV GOST DNV CSA UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP20 front panel conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
climate tolerance | Complies with IACS E10 for exposure to hot flashes Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes |
N/A | ||
ambient air temperature | -40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 0…3000m | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
flame retardant | V1 complies with UL 94 | N/A | ||
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts open (10 gn (11ms)) shock resistance Performance Contact closed state (15 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 77 mm | 77 mm | 77 mm | 77 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 95 mm | 86 mm | 86 mm | 86 mm |
Product Weight | 0.48kg | 0.32kg | 0.32kg | 0.32kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5cm | 5.275cm | 5.126cm | 5.069cm |
Package 1 Width | 9.2cm | 7.935cm | 7.988cm | 7.869cm |
Package 1 Length | 11.2cm | 9.441cm | 9.38cm | 9.164cm |
Package 1 Weight | 524.0g | 361.0g | 350.0g | 350.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 15 | 24 | 24 | 24 |
Package 2 Height | 15cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 8.211kg | 8.82kg | 8.921kg | 9.0kg |
Unit Type of Package 3 | P06 | PAL | PAL | PAL |
Number of Units in Package 3 | 240 | 384 | 384 | 384 |
Package 3 Height | 75cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Width | 80cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Length | 60cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Weight | 138kg | 142.72kg | 155.407kg | 145.664kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D09FDC | LC1D09FL | LC1D09M7C | LC1D09MDC |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-1 AC-3 AC-4 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
9 A 60 °C) at <= 440 V AC AC-3 for power circuit 25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at< = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 110VDC | 110VDC | 230V AC 50/60Hz | 230V DC |
Additional information | ||||
Motor power (kW) | 5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
2.2 kW at 220…230 V AC 50/60 Hz (AC-3) 4 kW at 380…400 V AC 50/60 Hz (AC-3) 4 kW at 415.. .440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660…690 V AC 50/60 Hz (AC-3 ) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 2.2 kW at 220…230 V AC 50/60 Hz (AC-3e) 4 kW at 380…400 V AC 50/60 Hz (AC-3e) 4 kW at 415…440 V AC 50/60 Hz (AC-3e) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 5.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 2.2 kW at 220…230 V AC 50/60 Hz (AC-3) 4 kW at 380…400 V AC 50/60 Hz (AC-3) 4 kW at 415…440 V AC 50/60 Hz (AC-3) 5.5 kW at at 660…690 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz ( AC-3e) 4 kW at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | Bring | None | N/A |
Conventional thermal current [Ith] | 25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
Rated short-time withstand current [Icw] | 105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signaling circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signaling circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 30 Mcycles | 30 Mcycles | 15 Mcycles | 30 Mcycles |
Electrical life | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 Ue <= 440 V 2 Mcycles 9 A AC-3 Ue <= 440 V 2 Mcycles 9 A AC-3e Ue <= 440 V |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 Ue at <= 440 V 2 Mcycles 6.6 A AC-3 Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 Ue <= 440 V 2 Mcycles 9 A AC-3 Ue <= 440 V 2 Mcycles 9 A AC-3e Ue <= 440 V 2 Mcycles 6.6 A AC-3e Ue Conditions 660/690 V |
Control loop characteristics | DC standard | DC low power consumption | AC at 50/60 Hz | |
Surge Suppression Module | Built-in bidirectional peak current limiting diode | Built-in bidirectional peak current limiting diode | No built-in surge suppression module | Built-in bidirectional peak current limiting diode |
Control voltage limit | 0.1…0.25 Uc -40…60 °C release 0.7…1.25 Uc -40…60 °C run |
0.1…0.3 Uc -40…70 °C release DC 0.8…1.25 Uc -40…60 °C run DC 1…1.25 Uc 60…70 °C run DC |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.1…0.25 Uc -40…60 °C release 0.7…1.25 Uc -40…60 °C run |
Surge power (W) | 5.4W (20°C) | 2.4W (20°C) | N/A | 5.4W (20°C) |
Holding power consumption(W) | 5.4 W at 20 °C | 2.4 W at 20 °C | 5.4 W at 20 °C | |
Rated operating power (W) | 5.4W | N/A | 5.4W | |
action time | 55 ms to close, 20 ms to break |
65.45…88.55 ms closed 20…30 ms open |
12…22 ms close 4…19 ms break |
53.55…72.45 ms closed 16…24 ms open |
time constant | 28ms | 40ms | 28ms | |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Power circuit: Bolt-on1 1…4 mm² Cable option: Flexible without wire terminals Power circuit: Bolt-on2 1…4 mm² Cable option: Flexible without wire terminal Power circuit: Bolt-on 1 1…4 mm² cable option: flexible cord with cable terminals Power circuit: screw-fastened2 1…2.5 mm² cable option: flexible cable with cable terminal Power circuit: screw-fastened1 cable option 1…4 mm² : Hard wire without wire terminal Power circuit: Bolt fastening2 1…4 mm² Cable selection: Hard wire without wire terminal Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible wire without wire wire Wire terminal control circuit: screw-on2 1…4 mm² cable selection: flexible without wire terminal control circuit: screw-on1 1…4 mm² cable selection: flexible with wire terminal control circuit: screw-tight Solid2 1…2.5 mm² Cable option: flexible cable with wire terminals Control circuit: screw-on1 1…4 mm² Cable option: solid without cable terminals Control circuit: screw-on2 1…4 mm² cable Type selection: hard wire without wire terminal |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Power circuit: screw connection |
Tightening torque | Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5 Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for tightening Phillips screw Control circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts Power supply circuit: 1.7 Nm Screwdriver pozidriv No. 2 for tightening via bolts |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade via cable connector: M3.5 Power circuit : 1.7 Nm Screwdriver No. 2 Phillips screw via cable connector Screw: M3.5 Power circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 Control circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Fasten with screwdriver pozidriv No. 2 Control circuit: 1.7 Nm Fasten with screwdriver pozidriv No. 2 for bolts |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
Chassis mounting rail installation |
environment | ||||
standard | GB 14048.4 IEC 60947-4-1 |
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 EN 60947-5-1 CSA C22.2 No 14 IEC 60947-5-1 EN 60947-4-1 |
certified product | CCC CE UKCA |
DNV GOST LROS (Lloyds register of shipping) BV CSA RINA UL GL CCC UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP20 front panel conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 0…3000m | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | N/A |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts open (10 gn (11ms)) shock resistance Performance Contact closed state (15 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
|
high | 77 mm | 77 mm | 77 mm | 77 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 95 mm | 95 mm | 86 mm | 95 mm |
Product Weight | 0.48 kg | 0.48 kg | 0.32kg | 0.48 kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5.7cm | 4.9cm | 5.03cm | 5.16cm |
Package 1 Width | 8.5cm | 11.1 cm | 7.83cm | 7.81cm |
Package 1 Length | 11.1 cm | 8.9cm | 9.27cm | 10.24cm |
Package 1 Weight | 541.476g | 506.0g | 360.78g | 493.0g |
Unit Type of Package 2 | CAR | S02 | S02 | S02 |
Number of Units in Package 2 | 21 | 15 | 24 | 21 |
Package 2 Height | 15.1 cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 29.3 cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.3 cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 11.369kg | 8.37kg | 9.0 kg | 10.777 kg |
Unit Type of Package 3 | PAL | PAL | PAL | |
Number of Units in Package 3 | 336 | 384 | 336 | |
Package 3 Height | 60.0cm | 60.0cm | 60.0cm | |
Package 3 Width | 80.0cm | 80.0cm | 80.0cm | |
Package 3 Length | 75.0cm | 75.0cm | 75.0cm | |
Package 3 Weight | 183.776 kg | 140.48kg | 178.702 kg | |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||
Part Number | LC1D09P7C | LC1D09Q7C |
Product Series | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor |
product short name | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 225 V DC |
Rated operating current [Ie] | 25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
25 A 60 °C) at <= 440 V AC AC-1 for power circuit 9 A 60 °C) at <= 440 V AC AC-3 for power circuit 9 A 60 °C) at < = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230 V AC 50/60 Hz | 380 V AC 50/60 Hz |
Additional information | ||
Motor power (kW) | 5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
5.5 kW at 500 V AC 50/60 Hz (AC-3) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3) 4 kW at 380/400 V AC 50/60 Hz (AC-3) 4 kW at 415/440 V AC 50/60 Hz (AC-3) 5.5 kW at 660/690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) 5.5 kW at 500 V AC 50/60 Hz (AC-3e) 2.2 kW at 220/240 V AC 50/60 Hz (AC-3e) 4 kW at… at 380/400 V AC 50/60 Hz (AC-3e) 4 kW at 415/440 V AC 50/60 Hz (AC-3e) 5.5 kW at 660/690 V AC 50/60 Hz (AC -3e) |
model | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO |
protection cap | None | None |
Conventional thermal current [Ith] | 25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
25 A at <60 °C for power circuits 10 A at <60 °C for signal circuits |
Rated short-time withstand current [Icw] | 105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
105 A at <40 °C – 10 s for power circuit 210 A at <40 °C – 1 s for power circuit 30 A at <40 °C – 10 min for power circuit 61 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 25 A gG at <= 690 V for power circuits type 1 20 A gG for power circuits for type 2 at <= 690 V |
average impedance | 2.5 mΩ – Ith 25 A 50 Hz for power loop | 2.5 mΩ – Ith 25 A 50 Hz for power loop |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III |
pollution level | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 15 Mcycles | 15 Mcycles |
Electrical life | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 2 Mcycles 6.6 A AC-3 at Ue at 660/690 V 2 Mcycles 9 A AC-3e Ue <= 440 V at 2 Mcycles 6.6 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
70 VA 60 Hz 0.75 20 °C) 70 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
7.5 VA 60 Hz 0.3 20 °C) 7 VA 50 Hz 0.3 20 °C) |
heat dissipation | 2…3 W at 50/60 Hz | 2…3 W at 50/60 Hz |
action time | 12…22 ms close 4…19 ms break |
12…22 ms close 4…19 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals Control circuit: screw-on2 1…2.5 mm² cable selection: flexible wire with wire terminals control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal Power circuit: Screw connection |
Tightening torque | Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 Flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Screwdriver No. 2 Phillips screw via cable connector Screw: M3.5 Power circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 Control circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 |
Power circuit: 1.7 Nm via screwdriver Ø 6 flat power circuit: 1.7 Nm via screwdriver No 2 Phillips screw control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw Power circuit: 1.7 Nm Screwdriver Ø 6 Flat-blade screw via cable connector: M3.5 Power circuit : 1.7 Nm Screwdriver No. 2 Phillips screw via cable connector Screw: M3.5 Power circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 Control circuit: 1.7 Nm Tighten with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | 17 V for signal return |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
Chassis mounting rail installation |
environment | ||
standard | GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed (Â 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 77 mm | 77 mm |
width | 45 mm | 45 mm |
depth | 86 mm | 86 mm |
Product Weight | 0.32kg | 0.32kg |
packaging unit | ||
Unit Type of Package 1 | PCE | PCE |
Number of Units in Package 1 | 1 | 1 |
Package 1 Height | 5.232 cm | 4.942 cm |
Package 1 Width | 7.906 cm | 7.732 cm |
Package 1 Length | 9.37 cm | 9.158 cm |
Package 1 Weight | 350.0g | 349.5g |
Unit Type of Package 2 | S02 | CAR |
Number of Units in Package 2 | 24 | 24 |
Package 2 Height | 15.0cm | 14.4 cm |
Package 2 Width | 30.0cm | 29.6 cm |
Package 2 Length | 40.0cm | 39.5 cm |
Package 2 Weight | 8.83kg | 8.5 kg |
Unit Type of Package 3 | PAL | PAL |
Number of Units in Package 3 | 384 | 384 |
Package 3 Height | 60.0cm | 60.0cm |
Package 3 Width | 80.0cm | 80.0cm |
Package 3 Length | 75.0cm | 75.0cm |
Package 3 Weight | 138.88 kg | 145.664 kg |
contract warranty | ||
Warranty | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details