Harmony – RM22TR – 3-Phase Control Relays – Schneider Control Relays
$ 84.26 – $ 156.86
SKU: N/A
Specifications
Main | ||
Part Number | RM22TR33 | RM22TU23 |
Product Series | Harmony Control Relays | Harmony Control Relays |
product type | 3-phase control relay | 3-phase control relay |
relay type | Control relay | Control relay |
Number of grid phases | Phase 3 | Phase 3 |
Relay name | RM22TR | RM22TR |
Relay Monitoring Parameters | Overvoltage and undervoltage monitoring Phase sequence Phase failure monitoring |
Undervoltage Monitoring Phase Sequence Phase Failure Monitoring |
delay type | Adjustable 0.1…30 s, +/- 10 % full scale value over threshold Tt | N/A |
Switching capacity in VA | 2000VA | 2000VA |
Measuring range | 380…480 V voltage AC | 380…480 V voltage AC |
contact type | 2 OC | 2 OC |
Additional information | ||
reset time | 1500 ms at maximum voltage | 1500 ms at maximum voltage |
Maximum Switching Voltage | 250V AC | 250V AC |
Minimum switching current [Imin] | 10 mA at 5 V DC | 10 mA at 5 V DC |
Maximum switching current | 8A AC | 8A AC |
Rated supply voltage [Us] | 380…480 V AC | 380…480 V AC |
Power supply voltage range | 304…576 V AC | 304…576 V AC |
operating limits | – 20 % + 20 % Un | – 20 % + 20 % Un |
Power consumption VA | 15 VA at 480 V AC 60 Hz | 15 VA at 480 V AC 60 Hz |
Voltage Monitoring Threshold | < 100 V AC | < 100 V AC |
supply voltage frequency | 50…60 Hz +/- 10 % | 50…60 Hz +/- 10 % |
output contact | 2 C/O | 2 C/O |
Rated output current | 8A | N/A |
set precision | +/- 10 % of full scale | +/- 10 % of full scale |
switching threshold error | <= 0.05 % per degree Celsius based on permissible ambient air temperature <= 1 % within supply voltage range |
<= 0.05 % per degree Celsius based on permissible ambient air temperature <= 1 % within supply voltage range |
Latency Accuracy Settings | 10P | 10P |
delay error | <= 0.05 % per degree Celsius based on permissible ambient air temperature <= 1 % within supply voltage range |
<= 0.05 % per degree Celsius based on permissible ambient air temperature <= 1 % within supply voltage range |
hysteresis | 2 % fixed optional | 2 % fixed optional |
Rising delay at power-up | 650ms | 650ms |
Maximum measuring cycle | 150 ms period measured in true rms value | 150 ms period measured in true rms value |
Threshold adjustment voltage | 2…20 % selected Un | 2…20 % selected Un |
voltage range | 380…480 VPP | 380…480 VPP |
Repeatability | +/- 0.5 % for input and measurement circuits +/- 3 % for time delay |
+/- 0.5 % for input and measurement circuits |
Measurement error | < 1 % over the entire range with a voltage change < 0.05 %/°C with a temperature change |
< 1 % over the entire range with a voltage change < 0.05 %/°C with a temperature change |
Response time | <= 300ms | <= 300ms |
Type of overvoltage | III according to IEC 60664-1 III according to UL 508 |
III according to IEC 60664-1 III according to UL 508 |
Insulation resistance | > 100 MΩ at 500 V DC conforming to IEC 60255-27 | > 100 MΩ at 500 V DC conforming to IEC 60255-27 |
installation location | Any position | Any position |
Wiring capacity | Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) Solid without wire terminal Screw terminal, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16 ) flexible wire with wire terminal screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) rigid wire without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² ( AWG 24…AWG 14) flexible wire with wire terminal |
Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) Solid without wire terminal Screw terminal, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16 ) flexible wire with wire terminal screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) rigid wire without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² ( AWG 24…AWG 14) flexible wire with wire terminal |
Tightening torque | 0.6…1 Nm conforming to IEC 60947-1 | 0.6…1 Nm conforming to IEC 60947-1 |
covering material | Flame retardant plastic | Flame retardant plastic |
LED status | LED (yellow) relay ON LED (green) energized |
LED (yellow) relay ON LED (green) energized |
installation method | 35 mm DIN rail conforming to EN/IEC 60715 | 35 mm DIN rail conforming to EN/IEC 60715 |
Electrical life | 100000 times | 100000 times |
Mechanical life | 10000000 times | 10000000 times |
use category | AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
Safe and reliable data | MTTFd = 388.1 years B10d = 350000 |
MTTFd = 388.1 years B10d = 350000 |
contact material | Cadmium free | Cadmium free |
width | 22.5 mm | 22.5 mm |
Product Weight | 0.09 kg | 0.09 kg |
environment | ||
Anti-instantaneous power failure | 10ms | 10ms |
electromagnetic compatibility | Exemption for use in residential, commercial and light-industrial environments Transmission standards per EN/IEC 61000-6-1 Exemption for industrial environments per EN/IEC 61000-6-2 Transmission standards for residential, commercial and light-industrial environments per EN/IEC 61000- 6-3 Transmission standards for industrial environments in accordance with EN/IEC 61000-6-4 Anti-static interference – test level: 6 kV (contact discharge) Level 3 in accordance with IEC 61000-4-2 Anti-static interference – test level: 8 kV (air Discharge) Class 3 Complies with IEC 61000-4-2 Radio Frequency Electromagnetic Field Radiation Immunity Test – Test Level: 10 V/m3 Class Complies with IEC 61000-4-3 Immunity to Fast Transients – Test Level: 4 kV (Direct Connection) Class 4 Complies with IEC 61000-4-4 Immunity to fast transients – Test level: 2 kV (capacitive coupling) level 4 Complies with IEC 61000-4-4 Surge discharge immunity – Test level: 4 kV (Common mode) level 4 Conforms to IEC 61000 -4-5 Surge Discharge Immunity- Test Level: 2 kV (Differential Mode) Level 4 Conforms to IEC 61000-4-5 Conducted and Radiated Emissions Group B 1 Conforms to CISPR 11 Conducted and Radiated Emissions Class B Conforms to CISPR 22 |
Exemption for use in residential, commercial and light-industrial environments Transmission standards per EN/IEC 61000-6-1 Exemption for industrial environments per EN/IEC 61000-6-2 Transmission standards for residential, commercial and light-industrial environments per EN/IEC 61000- 6-3 Transmission standards for industrial environments in accordance with EN/IEC 61000-6-4 Anti-static interference – test level: 6 kV (contact discharge) Level 3 in accordance with IEC 61000-4-2 Anti-static interference – test level: 8 kV (air Discharge) level 3 according to IEC 61000-4-2 radio frequency electromagnetic field radiation immunity test – test level: 10 V/m3 level according to IEC 61000-4-3 immunity to fast transients – test level: 4 kV (direct connection) level 4 Complies with IEC 61000-4-4 Immunity to Fast Transients – Test Level: 2 kV (Capacitive Coupling) Class 4 Complies with IEC 61000-4-4 Surge Discharge Immunity – Test Class: 4 kV (Common Mode) Class 4 Conforms to IEC 61000 -4-5 Surge Discharge Immunity- Test Level: 2 kV (Differential Mode) Level 4 Conforms to IEC 61000-4-5 Conducted and Radiated Emissions Group B 1 Conforms to CISPR 11 Conducted and Radiated Emissions Class B Conforms to CISPR 22 |
Standards compliant | EN/IEC 60255-1 | EN/IEC 60255-1 |
certified product | GL CSA RCM CE EAC CCC UL |
CSA RCM UL GL CE CCC EAC |
storage environment temperature | -40…70°C | -40…70°C |
ambient temperature | -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC |
-20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC |
Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
Anti-vibration | 0.075 mm (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) during operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) conforming to IEC 60068-2-6 during operation |
0.075 mm (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) during operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) conforming to IEC 60068-2-6 during operation |
impact resistance | 15 gn (duration = 11 ms) for non-operating according to IEC 60068-2-27 5 gn (duration = 11 ms) for operating according to IEC 60068-2-27 |
15 gn (duration = 11 ms) for non-operating according to IEC 60068-2-27 5 gn (duration = 11 ms) for operating according to IEC 60068-2-27 |
IP protection class | IP20 according to IEC 60529 (screw terminals) IP40 according to IEC 60529 (housing) IP50 according to IEC 60529 (front panel) |
IP20 according to IEC 60529 (screw terminals) IP40 according to IEC 60529 (housing) IP50 according to IEC 60529 (front panel) |
pollution level | 3 according to IEC 60664-1 3 according to UL 508 |
3 according to IEC 60664-1 3 according to UL 508 |
Dielectric test winding and winding, winding voltage to ground | 2.5 kV AC 50 Hz, 1 minute conforming to IEC 60255-27 | 2.5 kV AC 50 Hz, 1 minute conforming to IEC 60255-27 |
packaging unit | ||
Unit Type of Package 1 | PCE | PCE |
Number of Units in Package 1 | 1 | 1 |
Package 1 Height | 2.6cm | 2.6cm |
Package 1 Width | 8.2 cm | 8.2 cm |
Package 1 Length | 9.5cm | 9.5cm |
Package 1 Weight | 104.0g | 103.0g |
Unit Type of Package 2 | S02 | S02 |
Number of Units in Package 2 | 40 | 40 |
Package 2 Height | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm |
Package 2 Weight | 4.535kg | 4.656kg |
Unit Type of Package 3 | P06 | P06 |
Number of Units in Package 3 | 640 | 640 |
Package 3 Height | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm |
Package 3 Weight | 81.06kg | 82.996kg |
contract warranty | ||
Warranty | 18 months | 18 months |
Weight | N/A |
---|---|