SENTRON – Switch Disconnector 3LD – Main Switch – Siemens Switch Disconnector
$ 109.78
SKU: 3LD2064-1GP51
Specifications
Model | |
product number | 3LD2064-1GP51 |
product brand name | SENTRON |
product designation | 3LD Switch disconnector |
design of the product | Main switch |
display version for switch position indicator manual operation | 1 ON – 0 OFF |
type of switch | Molded-plastic enclosure for metric threaded joint |
design of the actuating element | Short rotary knob |
color of the actuating element | black |
design of handle | rotary operating mechanism, black |
type of the driving mechanism motor drive | No |
General technical data | |
number of poles | 3 |
number of poles note | N |
size of switch disconnector | 1 |
mechanical service life (operating cycles) typical | 100 000 |
electrical endurance (operating cycles) | 6 000 |
● at AC-23 A at 690 V | |
operating frequency maximum | 50 1/h |
degree of pollution | 3 |
Voltage | |
insulation voltage rated value | 690 V |
surge voltage resistance rated value | 6 kV |
operating voltage | |
● at AC rated value | 690 V |
operating frequency rated value | |
● minimum | 50 Hz |
● maximum | 60 Hz |
Protection class | |
protection class IP | IP65 |
degree of protection NEMA rating | 1, 4X, 12 |
protection class IP on the front | IP65 |
Dissipation | |
power loss [W] for rated value of the current at AC in hot operating state per pole | 0.5 W |
Current | |
operational current rated value | 16 A |
operational current | |
● at 40 °C rated value | 16 A |
● at 45 °C rated value | 16 A |
● at 50 °C rated value | 16 A |
● at 55 °C rated value | 16 A |
● at AC °C rated value | 16 A |
Main circuit | |
operational current | |
● at AC-21 at 690 V rated value | 16 A |
● at AC-21 A at 240 V rated value | 16 A |
● at AC-21 A at 400 V rated value | 16 A |
● at AC-21 A at 440 V rated value | 16 A |
● at AC-23 A at 400 V rated value | 16 A |
operating power | |
● at AC-23 A at 240 V rated value | 4 kW |
● at AC-23 A at 400 V rated value | 8 kW |
● at AC-23 A at 440 V rated value | 7.5 kW |
● at AC-23 A at 690 V rated value | 8 kW |
● at AC-3 at 240 V rated value | 3 kW |
● at AC-3 at 400 V rated value | 6 kW |
● at AC-3 at 690 V rated value | 5.5 kW |
Auxiliary circuit | |
number of CO contacts for auxiliary contacts | 0 |
number of NC contacts for auxiliary contacts | 1 |
number of NO contacts for auxiliary contacts | 1 |
operating voltage of auxiliary contacts at AC maximum | 500 V |
continuous current of the auxiliary contact rated value | 10A |
insulation voltage of the auxiliary switch rated value | 500 V |
Suitability | |
suitability for use | |
● main switch | Yes |
● switch disconnector | Yes |
● EMERGENCY OFF switch | No |
● safety switch | Yes |
● maintenance/repair switch | Yes |
Product details | |
product feature can be locked into OFF position | Yes |
accessories | |
product extension optional | |
● motor drive | No |
● voltage trigger | No |
number of connectable NC contacts for auxiliary contacts attachable maximum | 2 |
number of connectable NO contacts for auxiliary contacts attachable maximum | 3 |
number of connectable CO contacts for auxiliary contacts attachable maximum | 0 |
number of bracket locks maximum | 3 |
hasp thickness of the bracket locks | 4 … 8 mm |
Short circuit | |
conditional short-circuit current with line-side fuse protection | |
● at 690 V by gG fuse rated value | 50 kA |
let-through current with closed switch | |
● at 240 V for combination switch + gG fuse maximum | 3 kA |
● at 440 V for combination switch + gG fuse maximum | 3 kA |
● at 690 V for combination switch + gG fuse maximum permissible | 3 kA |
I2t value with closed switch | |
● at 240 V for combination switch + gG fuse maximum | 2.5 kA2.s |
● at 440 V for combination switch + gG fuse maximum | 2.5 kA2.s |
● at 690 V for combination switch + gG fuse maximum | 3 kA2.s |
design of the fuse link | |
● for short-circuit protection of the main circuit required | fuse gL/gG: 20 A |
● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
operational current of upstream fuse rated value | 20 A |
according UL | |
operational current at AC according to UL 508/UL 609474-1 rated value | 16 A |
operating voltage at AC at 50/60 Hz according to UL 508/UL 60947-4-1 rated value | 600 V |
active power [hp] at AC at 480 V according to UL 508/UL 60947-4-1 rated value | 7.5 |
active power [hp] at AC at 600 V according to UL 508/UL 60947-4-1 rated value | 10 |
short-time withstand current (SCCR) at 600 V according to UL 508/UL 60947-4-1 | 5 kA |
continuous current of upstream fuse according to UL rated value | 50 A |
type of fuse according to UL | RK5 |
Connections | |
AWG number as coded connectable conductor cross section solid | |
● maximum | 10 |
● minimum | 18 |
type of connectable conductor cross-sections for copper conductor | |
● solid | 1x (1…6mm²) |
● finely stranded with core end processing | 1x (1…4mm²) |
● stranded | 1x (1..6mm²) |
type of connectable conductor cross-sections for auxiliary contacts | |
● solid | lateral auxiliary switch 2x (0,75 … 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 … 2,5mm²) |
● finely stranded with core end processing | lateral auxiliary switch 2x (0,75 … 1,5mm²), 1x 2,5mm²; front auxiliary switch 1x 2,5mm² |
● stranded | lateral auxiliary switch 2x (0,75 … 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 … 2,5mm²) |
type of electrical connection | |
● for main current circuit | box terminal |
● for auxiliary contacts | connection terminals |
Mechanical Design | |
height | 152 mm |
width | 100 mm |
depth | 117 mm |
type of device | fixed mounting |
fastening method | Complete unit in enclosure |
fastening method | |
● 4-hole front mounting | No |
● front mounting with central attachment | Yes |
● rail mounting | No |
net weight | 455 g |
Environmental conditions | |
ambient temperature during operation | -25 °C |
● minimum | |
● maximum | 55 °C |
ambient temperature during storage | -25 °C |
● minimum | |
● maximum | 55 °C |
Weight | 0.422 kg |
---|---|