Modicon M221 – IO Transistor PNP – Schneider PLC

$ 119.24$ 308.66

SKU: N/A

Specifications

Main
Part Number TM221C16T TM221C24T TM221C40T
Range of product Modicon M221 Modicon M221 Modicon M221
Product or component type Logic controller Logic controller Logic controller
[Us] rated supply voltage 24 V DC 24 V DC 24 V DC
discrete input number 9, discrete input 4 fast input conforming to IEC 61131-2 Type 1 14, discrete input 4 fast input conforming to IEC 61131-2 Type 1 24, discrete input 4 fast input conforming to IEC 61131-2 Type 1
analogue input number 2 at 0…10 V 2 at 0…10 V 2 at 0…10 V
Discrete output type Transistor Transistor Transistor
discrete output number 7 transistor 2 fast output 10 transistor 2 fast output 16 transistor 2 fast output
discrete output voltage 24 V DC 24 V DC 24 V DC
discrete output current 0.5 A 0.5 A 0.5 A
Complementary
Discrete I/O number 16 24 40
maximum number of I/O expansion module 4 for transistor output
4 for relay output
7 for transistor output
7 for relay output
7 for relay output
Supply voltage limits 20.4…28.8 V 20.4…28.8 V 20.4…28.8 V
Inrush current 35 A 35 A 35 A
maximum power consumption in W 10 W at 24 V (with max number of I/O expansion module)
3.9 W at 24 V (without I/O expansion module)
13 W at 24 V (with max number of I/O expansion module)
4.1 W at 24 V (without I/O expansion module)
4.1 W at 24 V (without I/O expansion module)
16 W at 24 V (with max number of I/O expansion module)
power supply output current 0.325 A 5 V for expansion bus
0.15 A 24 V for expansion bus
0.52 A 5 V for expansion bus
0.2 A 24 V for expansion bus
0.52 A 5 V for expansion bus
0.3 A 24 V for expansion bus
discrete input logic Sink or source (positive/negative) Sink or source (positive/negative) Sink or source (positive/negative)
Discrete input voltage 24 V 24 V 24 V
Discrete input voltage type DC DC DC
Analogue input resolution 10 bits 10 bits 10 bits
LSB value 10 mV 10 mV 10 mV
conversion time 1 ms per channel + 1 controller cycle time for analogue input analog input 1 ms per channel + 1 controller cycle time for analogue input analog input 1 ms per channel + 1 controller cycle time for analogue input analog input
permitted overload on inputs +/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
voltage state 1 guaranteed >= 15 V for input >= 15 V for input >= 15 V for input
voltage state 0 guaranteed <= 5 V for input <= 5 V for input <= 5 V for input
discrete input current 7 mA for discrete input
5 mA for fast input
7 mA for discrete input
5 mA for fast input
7 mA for discrete input
5 mA for fast input
input impedance 3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
response time 35 µs turn-off, I2…I5 terminal(s) for input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
5 µs turn-on, turn-off, Q0…Q1 terminal(s) for output
50 µs turn-on, turn-off, Q2…Q3 terminal(s) for output
300 µs turn-on, turn-off, other terminals terminal(s) for output
35 µs turn-off, I2…I5 terminal(s) for input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
5 µs turn-on, turn-off, Q0…Q1 terminal(s) for output
50 µs turn-on, turn-off, Q2…Q3 terminal(s) for output
300 µs turn-on, turn-off, other terminals terminal(s) for output
35 µs turn-off, I2…I5 terminal(s) for input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
5 µs turn-on, turn-off, Q0…Q1 terminal(s) for output
50 µs turn-on, turn-off, Q2…Q3 terminal(s) for output
300 µs turn-on, turn-off, other terminals terminal(s) for output
configurable filtering time 0 ms for input
3 ms for input
12 ms for input
0 ms for input
3 ms for input
12 ms for input
0 ms for input
3 ms for input
12 ms for input
Discrete output logic Positive logic (source) Positive logic (source) Positive logic (source)
maximum current per output common 3.5 A 5A 4A
output frequency 100 kHz for fast output (PWM/PLS mode) at Q0…Q1
5 kHz for output at Q2…Q3
0.1 kHz for output at Q4…Q6
100 kHz for fast output (PWM/PLS mode) at Q0…Q1
5 kHz for output at Q2…Q3
0.1 kHz for output at Q4…Q9
100 kHz for fast output (PWM/PLS mode) at Q0…Q1
5 kHz for output at Q2…Q3
0.1 kHz for output at Q4…Q15
absolute accuracy error +/- 1 % of full scale for analog input +/- 1 % of full scale for analog input +/- 1 % of full scale for analog input
maximum leakage current 0.1 mA for transistor output 0.1 mA for transistor output 0.1 mA for transistor output
maximum voltage drop <1 V <1 V <1 V
mechanical durability 20000000 cycles for transistor output 20000000 cycles for transistor output 20000000 cycles for transistor output
maximum tungsten load <12 W for output and fast output <12 W for output and fast output <12 W for output and fast output
protection type Overload and short-circuit protection at 0.2 A Overload and short-circuit protection at 1 A Overload and short-circuit protection at 1 A
reset time 1 s automatic reset 1 s automatic reset 1 s automatic reset
memory capacity 256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up 256 kB built-in flash memory for backup of application and data 256 kB built-in flash memory for backup of application and data 256 kB built-in flash memory for backup of application and data
data storage equipment 2 GB SD card (optional) 2 GB SD card (optional) 2 GB SD card (optional)
battery type BR2032 lithium non-rechargeable, battery life: 4 year(s) BR2032 lithium non-rechargeable, battery life: 4 year(s) BR2032 lithium non-rechargeable, battery life: 4 year(s)
backup time 1 year at 25 °C (by interruption of power supply) 1 year at 25 °C (by interruption of power supply) 1 year at 25 °C (by interruption of power supply)
execution time for 1 KInstruction 0.3 ms for event and periodic task 0.3 ms for event and periodic task 0.3 ms for event and periodic task
execution time per instruction 0.2 µs Boolean 0.2 µs Boolean 0.2 µs Boolean
exct time for event task 60 µs response time 60 µs response time 60 µs response time
Maximum size of object areas 512 %KW constant words
512 %M memory bits
255 %TM timers
8000 %MW memory words
255 %C counters
512 %KW constant words
255 %C counters
8000 %MW memory words
255 %TM timers
512 %M memory bits
255 %TM timers
512 %M memory bits
255 %C counters
512 %KW constant words
8000 %MW memory words
Realtime clock With With With
clock drift <= 30 s/month at 25 °C <= 30 s/month at 25 °C <= 30 s/month at 25 °C
regulation loop Adjustable PID regulator up to 14 simultaneous loops Adjustable PID regulator up to 14 simultaneous loops Adjustable PID regulator up to 14 simultaneous loops
positioning functions Position PTO 2 axe(s)pulse/direction mode (100 kHz)
Position PTO 1 axe(s)CW/CCW mode (100 kHz)
Position PTO 2 axe(s)pulse/direction mode (100 kHz)
Position PTO 1 axe(s)CW/CCW mode (100 kHz)
Position PTO 2 axe(s)pulse/direction mode (100 kHz)
Position PTO 1 axe(s)CW/CCW mode (100 kHz)
Function available Frequency generator
PWM
PLS
PWM
PLS
Frequency generator
Frequency generator
PWM
PLS
counting input number 4 fast input (HSC mode) at 100 kHz 32 bits 4 fast input (HSC mode) at 100 kHz 32 bits 4 fast input (HSC mode) at 100 kHz 32 bits
counter function Pulse/direction
A/B
Single phase
A/B
Single phase
Pulse/direction
Pulse/direction
Single phase
A/B
integrated connection type USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
supply (Serial)serial link supply: 5 V, <200 mA (Serial)serial link supply: 5 V, <200 mA (Serial)serial link supply: 5 V, <200 mA
transmission rate 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
communication port protocol USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
local signalling 1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
electrical connection Removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
Removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
maximum cable distance between devices Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
Shielded cable: <3 m for fast output
Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
Shielded cable: <3 m for fast output
Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
Shielded cable: <3 m for fast output
insulation Between input and internal logic at 500 V AC
Non-insulated between inputs
Between output and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between input and ground at 500 V AC
Between supply and internal logic at 2300 V AC
Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC
Non-insulated between inputs
Between output and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC
Non-insulated between inputs
Between output and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Marking CE CE CE
mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height 90 mm 90 mm 90 mm
Depth 70 mm 70 mm 70 mm
Width 95 mm 110 mm 160 mm
Net weight 0.346 kg 0.395 kg 0.456 kg
Environment
standards EN/IEC 61010-2-201
EN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61010-2-201
EN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61010-2-201
Product certifications RCM
IACS E10
LR
cULus
CSA
ABS
EAC
DNV-GL
DNV-GL
LR
cULus
RCM
EAC
IACS E10
CSA
ABS
CSA
IACS E10
DNV-GL
ABS
EAC
cULus
RCM
LR
Environmental characteristic Ordinary and hazardous location Ordinary and hazardous location Ordinary and hazardous location
resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields 10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
surge withstand 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances 10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Immunity to microbreaks 10 ms 10 ms 10 ms
ambient air temperature for operation -10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C
relative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protection IP20 with protective cover in place IP20 with protective cover in place IP20 with protective cover in place
Pollution degree <= 2 <= 2 <= 2
Operating altitude 0…2000 m 0…2000 m 0…2000 m
Storage altitude 0…3000 m 0…3000 m 0…3000 m
vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
shock resistance 147 m/s² for 11 ms 147 m/s² for 11 ms 147 m/s² for 11 ms
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 11.129 cm 11.021 cm 11.172 cm
Package 1 Width 14.031 cm 14.142 cm 14.117 cm
Package 1 Length 14.163 cm 15.497 cm 21.084 cm
Package 1 Weight 551.0 g 601.0 g 750.0 g
Unit Type of Package 2 CAR CAR CAR
Number of Units in Package 2 20 20 12
Package 2 Height 28.8 cm 29.2 cm 29.2 cm
Package 2 Width 39.1 cm 39.6 cm 39.6 cm
Package 2 Length 56.6 cm 56.4 cm 56.8 cm
Package 2 Weight 11.98 kg 13.16 kg 10.101 kg

 

Weight N/A
Dimensions N/A

Related products