TeSys T – Motor Controller – Modbus – Schneider Digitized Motor Starters

$ 330.22$ 373.56

SKU: N/A

Specifications

Main
Part Number

LTMR08MFM

LTMR27MFM

LTMR100MFM

Range TeSys TeSys TeSys
Product name TeSys T TeSys T TeSys T
Device short name LTMR LTMR LTMR
Product or component type Motor controller Motor controller Motor controller
Device application Equipment monitoring and control Equipment monitoring and control Equipment monitoring and control
Measurement current 0.4…8 A 1.35…27 A 5…100 A
[Us] rated supply voltage 100…240 V AC 50/60 Hz 100…240 V AC 50/60 Hz 100…240 V AC 50/60 Hz
Current consumption 8…62.8 mA 8…62.8 mA 8…62.8 mA
supply voltage limits 93.5…264 V AC 93.5…264 V AC 93.5…264 V AC
Communication port protocol Modbus Modbus Modbus
bus type Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs
Complementary
[Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1 100 kA conforming to EN/IEC 60947-4-1 100 kA conforming to EN/IEC 60947-4-1
associated fuse rating 4 A gG for output
0.5 A gG for control circuit
4 A gG for output
0.5 A gG for control circuit
4 A gG for output
0.5 A gG for control circuit
protection type Reverse polarity protection
Locked rotor
Earth-leakage protection
Thermal overload protection
Phase failure
Overload
Thermal protection
Power factor variation
Load fluctuation
Phase unbalance
Overload (long time)
Reverse polarity protection
Overload (long time)
Earth-leakage protection
Phase unbalance
Overload
Load fluctuation
Phase failure
Power factor variation
Thermal protection
Locked rotor
Thermal overload protection
Load fluctuation
Earth-leakage protection
Overload (long time)
Overload
Locked rotor
Thermal protection
Thermal overload protection
Power factor variation
Reverse polarity protection
Phase failure
Phase unbalance
Network and machine diagnosis type Event recording
Fault recording
Waiting time after overload tripping
Running hours counter/operating time
Phase fault and earth fault trip counters
Trip context information
Starting current and time
Motor control command recording
Remaining operating time before overload tripping
Trip history information
Fault recording
Starting current and time
Remaining operating time before overload tripping
Waiting time after overload tripping
Motor control command recording
Event recording
Trip history information
Running hours counter/operating time
Phase fault and earth fault trip counters
Trip context information
Motor control command recording
Starting current and time
Trip history information
Phase fault and earth fault trip counters
Running hours counter/operating time
Remaining operating time before overload tripping
Fault recording
Trip context information
Event recording
Waiting time after overload tripping
Logic input number 6 6 6
input current 3.1 mA at 100 V
7.5 mA at 240 V
3.1 mA at 100 V
7.5 mA at 240 V
3.1 mA at 100 V
7.5 mA at 240 V
current state 0 guaranteed Logic input: 0…40 V and <= 15 mA for 25 ms Logic input: 0…40 V and <= 15 mA for 25 ms Logic input: 0…40 V and <= 15 mA for 25 ms
current state 1 guaranteed Logic input: 79…264 V and >= 2 mA for 25 ms Logic input: 79…264 V and >= 2 mA for 25 ms Logic input: 79…264 V and >= 2 mA for 25 ms
maximum output switching frequency 2 Hz 2 Hz 2 Hz
load current 5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Maximum operating rate 1800 cyc/h 1800 cyc/h 1800 cyc/h
contacts type and composition 1 NO + 1 NC fault signal
3 NO
1 NO + 1 NC fault signal
3 NO
1 NO + 1 NC fault signal
3 NO
Metering type Average current Iavg
Temperature
Earth-fault current
Imbalance current
Phase current I1, I2, I3 RMS
Temperature
Phase current I1, I2, I3 RMS
Average current Iavg
Earth-fault current
Imbalance current
Temperature
Earth-fault current
Average current Iavg
Imbalance current
Phase current I1, I2, I3 RMS
measurement accuracy 5…15 % earth fault current internal measurement
1 % voltage (100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
5…15 % earth fault current internal measurement
1 % voltage (100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
5…15 % earth fault current internal measurement
1 % voltage (100…830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
5 % active and reactive power
0,02 current
Overvoltage category III III III
Connection pitch 5.08 mm 5.08 mm 5.08 mm
connections – terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
Pollution degree 3 3 3
electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Width 91 mm 91 mm 91 mm
Height 61 mm 61 mm 61 mm
Depth 122.5 mm 122.5 mm 122.5 mm
Net weight 0.53 kg 0.53 kg 0.53 kg
Web services Web server Web server Web server
Compatibility code LTMR LTMR LTMR
Environment
Standards IACS E10
IEC 60947-4-1
UL 508
EN 60947-4-1
CSA C22.2 No 14
CSA C22.2 No 14
UL 508
EN 60947-4-1
IEC 60947-4-1
IACS E10
IACS E10
IEC 60947-4-1
UL 508
EN 60947-4-1
CSA C22.2 No 14
Product certifications ABS
KERI
BV
EAC
CSA
GL
C-Tick
ATEX
UL
RMRoS
NOM
CCC
DNV
RINA
LROS (Lloyds register of shipping)
RMRoS
LROS (Lloyds register of shipping)
RINA
ABS
CCC
EAC
UL
GL
NOM
DNV
KERI
ATEX
BV
CSA
C-Tick
LROS (Lloyds register of shipping)
UL
ABS
ATEX
EAC
CCC
BV
RINA
DNV
C-Tick
RMRoS
CSA
GL
NOM
KERI
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
fire resistance 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
ambient air temperature for operation -20…60 °C -20…60 °C -20…60 °C
Ambient air temperature for storage -40…80 °C -40…80 °C -40…80 °C
operating altitude <= 2000 m without derating <= 2000 m without derating <= 2000 m without derating
mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection IP20 IP20 IP20
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 7.200 cm 7.2 cm 7.2 cm
Package 1 Width 10.000 cm 10.0 cm 10.0 cm
Package 1 Length 13.600 cm 13.6 cm 13.6 cm
Package 1 Weight 524.0 g 525.0 g 536.0 g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 10 10 10
Package 2 Height 15.000 cm 15.0 cm 15.0 cm
Package 2 Width 30.000 cm 30.0 cm 30.0 cm
Package 2 Length 40.000 cm 40.0 cm 40.0 cm
Package 2 Weight 5.594 kg 5.604 kg 5.586 kg
Contractual warranty
Warranty 18 months 18 months 18 months

 

Weight N/A
Dimensions N/A