PowerLogic PM5350 – Power Meter – Schneider Basic Metering
$ 482.02
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 31th Harmonic. Include a non-volatile memory for several parameters and alarms. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 85 to 265 VAC and 100 to 300 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20V AC to 480V AC, CAT III or 20V AC to 690V AC, CAT II at 45 Hz to 65 Hz. The range of measurement voltage between Phase and Neutral is 20V AC to 277V AC, CAT III or 20V AC to 400V AC, CAT II at 45 Hz to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has four digital inputs and dual relay outputs. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.24 inches (57 millimetres), height 3.78 inches (96 millimetres) and product weight 8.8 onces (250 g).
Specifications
Main | |
Part Number | METSEPM5350P |
Range | PowerLogic |
Product name | PowerLogic PM5350 |
Device short name | PM5350P |
Product or component type | Power meter |
Complementary | |
power quality analysis | Total demand distortion |
total harmonic distortion | |
up to the 31st harmonic | |
Device application | Multi-tariff |
Power monitoring | |
type of measurement | Current |
Voltage | |
Frequency | |
Power factor | |
Energy | |
Phase angle | |
Apparent power | |
Active power | |
Reactive power | |
Individual harmonics up to the 31st | |
supply voltage | 85…265 V AC 45…65 Hz |
100…300 V DC | |
Network frequency | 50 Hz |
60 Hz | |
[In] rated current | 1:00 AM |
5:00 AM | |
type of network | 3P + N |
3P | |
1P + N | |
power consumption in W | 4 W at 125 V DC |
5 W at 300 V DC | |
4 W at 120 V AC | |
5 W at 230 V AC | |
power consumption in VA | 7 VA at 120 V AC |
9 VA at 230 V AC | |
11.9 VA at 265 V AC | |
Display type | LCD screen with white backlighting |
Display colour | Monochrome |
Display resolution | 128 x 128 pixels |
Sampling rate | 64 samples/cycle |
Measurement current | 1:00 AM |
5:00 AM | |
analogue input type | Current 0.05…9 A (impedance <= 0.3 mOhm) |
measurement voltage | 20…700 V AC 45…70 Hz phase to phase |
20…404 V AC 45…70 Hz phase to neutral | |
Frequency measurement range | 45…70 Hz |
measurement accuracy | Current 0.5 % |
Voltage 0.5 % | |
Frequency 0.05 % | |
Power factor 0,01 | |
accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
Class 0.5 active energy conforming to IEC 61557-12 | |
Class 2 reactive energy conforming to IEC 62053-23 | |
Class 2 reactive energy conforming to IEC 61557-12 | |
Class 0.5 power conforming to IEC 61557-12 | |
Class 5 harmonic distorsion (I THD & U THD) conforming to IEC 61557-12 | |
Class 5 individual harmonics up to the 15th conforming to IEC 61557-12 | |
number of digital inputs | 4 digital |
digital input voltage rating | Discrete input: 18.5…36 V DC 2 Hz 110 kOhm |
number of digital outputs | 2 relay |
1 pulse | |
maximum switching current | Relay outputs 2 A at 250 V AC inductive load, cos phi = 0.4 |
multi-tariff | Tariff (4) |
communication port protocol | JBUS |
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none – 2-wire, insulation 2500 V | |
communication port support | Terminal block: RS485 |
realtime clock | Built-in battery (3 years), drift: +/- 0.5 s/day |
Data recording | Min/max of instantaneous values |
Alarms | |
Web services | Upgrade drive firmware |
Mounting mode | Flush-mounted |
Type of installation | Indoor installation |
Standards | IEC 61010-1 |
IEC 61557-12 | |
IEC 62052-11 | |
IEC 62053-22 | |
product certifications | CE conforming to IEC 61010-1 |
CULus conforming to CSA C22.2 No 61010-1 | |
UL conforming to UL 61010-1 | |
Width | 96 mm |
depth | 44 mm embedded: |
13 mm outside: | |
57 mm total: | |
Height | 96 mm |
Product weight | 0.25 kg |
Environment | |
electromagnetic compatibility | Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 |
Electrostatic discharge conforming to IEC 61000-4-2 | |
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 | |
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 | |
Conducted RF disturbances conforming to IEC 61000-4-6 | |
Immunity to magnetic fields conforming to IEC 61000-4-8 | |
Immunity to voltage dips conforming to IEC 61000-4-11 | |
Conducted and radiated emissions class A conforming to EN 55011 | |
Limits for harmonic current emissions conforming to IEC 61000-3-2 | |
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 | |
Electrical insulation class | Double insulation |
Class II | |
measurement category | Category III 480 V conforming to IEC 61010-1 |
Category III 300 V conforming to UL 61010-1 | |
Category III 300 V conforming to CSA C22.2 No 61010-1 | |
Category II 690 V conforming to IEC 61010-1 | |
Overvoltage category | III |
IP degree of protection | IP30 back: conforming to IEC 60529 |
IP51 front face: conforming to IEC 60529 | |
relative humidity | 5…95 % at 50 °C non-condensing |
pollution degree | 2 |
ambient air temperature for operation | -25…70 °C |
-20…70 °C at for display module | |
-25…20 °C at with derating | |
Ambient air temperature for storage | -40…85 °C |
Operating altitude | 0…3000 m |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 11.077 cm |
Package 1 Width | 12.447 cm |
Package 1 Length | 12.715 cm |
Package 1 Weight | 410.0 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 12 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 5.571 kg |
Weight | 0.25 kg |
---|---|
Dimensions | 5.7 × 9.6 × 9.6 cm |