SIMATIC S7-400 – CP 443-1 Communications Processor – Siemens Communication Processor
$ 2,804.62
SKU: 6GK7443-1EX30-0XE0
- The CP 443-1 is used to connect the SIMATIC S7-400 to Industrial Ethernet networks. With its own processor, it relieves the CPU of communications tasks and facilitates additional connections.
The CP 443-1 offers communication options with
- PGs/PCs
- Host computers
- HMI systems
- SIMATIC S5/S7/C7 systems
- PROFINET IO devices
Siemens Communication Processor S7-400 Product Specifications:
Article number | 6GK7443-1EX30-0XE0 | |
product type designation | CP 443-1 | |
transfer rate | ||
transfer rate | ||
● at the 1st interface | 10 … 100 Mbit/s | |
interfaces | ||
number of interfaces according to Industrial Ethernet | 2 | |
number of electrical connections | ||
● at the 1st interface according to Industrial Ethernet | 2 | |
type of electrical connection | ||
● at the 1st interface according to Industrial Ethernet | RJ45 port | |
design of the removable storage | ||
● C-PLUG | No | |
supply voltage, current consumption, power loss | ||
type of voltage of the supply voltage | DC | |
supply voltage 1 from backplane bus | 5 V | |
relative symmetrical tolerance at DC | ||
● at 5 V | 5 % | |
consumed current | ||
● from backplane bus at DC at 5 V typical | 1.4 A | |
power loss [W] | 7.25 W | |
ambient conditions | ||
ambient temperature | ||
● during operation | 0 … 60 °C | |
● during storage | -40 … +70 °C | |
● during transport | -40 … +70 °C | |
relative humidity | ||
● at 25 °C without condensation during operation maximum | 95 % | |
protection class IP | IP20 | |
design, dimensions and weights | ||
module format | Compact module S7-400 single width | |
width | 25 mm | |
height | 290 mm | |
depth | 210 mm | |
net weight | 0.7 kg | |
product features, product functions, product components general | ||
number of units | ||
● per CPU maximum | 14 | |
● note | max. 4 as PN IO ctrl. | |
performance data open communication | ||
number of possible connections for open communication by means of SEND/RECEIVE blocks maximum | 64 | |
data volume | ||
● as user data per ISO connection for open communication by means of SEND/RECEIVE blocks maximum | 8 Kibyte | |
● as user data per ISO on TCP connection for open communication by means of SEND/RECEIVE blocks maximum | 8 Kibyte | |
● as user data per TCP connection for open communication by means of SEND/RECEIVE blocks maximum | 8 Kibyte | |
● as user data per UDP connection for open IE communication by means of SEND/RECEIVE blocks maximum | 2 Kibyte | |
number of possible connections for open communication | ||
● by means of T blocks maximum | 64 | |
data volume | ||
● as user data per ISO on TCP connection for open communication by means of T blocks maximum | 1 452 byte | |
performance data S7 communication | ||
number of possible connections for S7 communication | ||
● maximum | 128; when using several CPUs | |
● with PG connections maximum | 2 | |
performance data multi-protocol mode | ||
number of active connections with multi-protocol mode | 128 | |
performance data PROFINET communication as PN IO controller | ||
product function PROFINET IO controller | Yes | |
number of PN IO devices on PROFINET IO controller operable total | 128 | |
number of PN IO IRT devices on PROFINET IO controller operable | 64 | |
number of external PN IO lines with PROFINET per rack | 4 | |
data volume | ||
● as user data for input variables as PROFINET IO controller maximum | 4 Kibyte | |
● as user data for output variables as PROFINET IO controller maximum | 4 Kibyte | |
● as user data for input variables per PN IO device as PROFINET IO controller maximum | 1 433 byte | |
● as user data for output variables per PN IO device as PROFINET IO controller maximum | 1 433 byte | |
● as user data for input variables per PN IO device for each sub-module as PROFINET IO controller maximum | 240 byte | |
● as user data for output variables per PN IO device for each sub-module as PROFINET IO controller maximum | 240 byte | |
product functions management, configuration, engineering | ||
product function MIB support | Yes | |
protocol is supported | ||
● SNMP v1 | Yes | |
● DCP | Yes | |
● LLDP | Yes | |
configuration software | ||
● required | STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher | |
product functions diagnostics | ||
product function web-based diagnostics | Yes | |
product functions switch | ||
product feature switch | Yes | |
product function | ||
● switch-managed | No | |
● with IRT PROFINET IO switch | Yes | |
● configuration with STEP 7 | Yes | |
product functions redundancy | ||
product function | ||
● ring redundancy | Yes | |
● redundancy manager | Yes | |
protocol is supported Media Redundancy Protocol (MRP) | Yes | |
product functions security | ||
product function | ||
● password protection for Web applications | No | |
● ACL – IP-based | Yes | |
● ACL – IP-based for PLC/routing | No | |
● switch-off of non-required services | Yes | |
● blocking of communication via physical ports | Yes | |
● log file for unauthorized access | No | |
product functions time | ||
product function SICLOCK support | Yes | |
product function pass on time synchronization | Yes | |
protocol is supported | ||
● NTP | Yes | |
● SIMATIC time synchronization (SIMATIC Time) | Yes | |
standards, specifications, approvals hazardous environments | ||
certificate of suitability CCC for hazardous zone according to GB standard | Yes |
Weight | 0.7 kg |
---|---|
Dimensions | 0.1 × 0.1 × 0.1 cm |