The IM 155-5 PN interface module enables the connection of ET 200MP to PROFINET and handles the communication between the modules and the higher-level I/O controller autonomously.
| Article number | 6ES7155-5AA00-0AA0 | 6ES7155-5AA00-0AC0 | 6ES7155-5AA01-0AB0 | |
| ET 200MP, IM 155-5 PN BA | ET 200MP, IM 155-5 PN HF | ET 200MP, IM 155-5 PN ST | ||
| General information | ||||
| Product type designation | IM 155-5 PN BA | IM 155-5 PN HF | IM 155-5 PN ST | |
| HW functional status | From FS02 | From FS03 | From FS01 | |
| Firmware version | V4.3.0 | V4.4 | V4.1.0 | |
| ● FW update possible | Yes | |||
| Vendor identification (VendorID) | 0x002A | 002AH | 0x002A | |
| Device identifier (DeviceID) | 0X0312 | 0X0312 | 0X0312 | |
| Product function | ||||
| ● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | |
| ● Module swapping during operation (hot swapping) | No | Yes; In combination with active backplane bus | No | |
| ● Isochronous mode | No | Yes | Yes | |
| Engineering with | ||||
| ● STEP 7 TIA Portal configurable/integrated from version | V15.1 with HSP 187 | V16 with HSP 308 | V14 or higher with HSP 0223 / integrated with V15 or higher | |
| ● STEP 7 configurable/integrated from version | V5.5 SP3 / – | V5.5 SP3 / – | GSDML V2.32 | |
| ● PROFINET from GSD version/GSD revision | V2.3 / – | V2.3 / – | V2.3 / – | |
| Configuration control | ||||
| via user data | No | No | No | |
| via dataset | No | Yes | Yes | |
| Supply voltage | ||||
| Rated value (DC) | 24 V | 24 V | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | |
| Reverse polarity protection | Yes | Yes | Yes | |
| Short-circuit protection | Yes | Yes | Yes | |
| Mains buffering | ||||
| ● Mains/voltage failure stored energy time | 5 ms | 5 ms | 10 ms | |
| Input current | ||||
| Current consumption (rated value) | 1 A | 0.2 A | 0.2 A | |
| Current consumption, max. | 1.7 A | 1.2 A | 1.2 A | |
| Inrush current, max. | 2.8 A | 9 A | 9 A | |
| I²t | 0.04 A²·s | 0.09 A²·s | 0.09 A²·s | |
| Power | ||||
| Infeed power to the backplane bus | 14 W | 14 W | 14 W | |
| Power available from the backplane bus | 2.3 W | 2.3 W | ||
| Power loss | ||||
| Power loss, typ. | 3 W | 4.5 W | 4.5 W | |
| Address area | ||||
| Address space per module | ||||
| ● Address space per module, max. | 64 byte; per input / output | 256 byte; per input / output | 256 byte; per input / output | |
| Address space per station | ||||
| ● Address space per station, max. | 64 byte; per input / output | 512 byte; per input / output | 512 byte; per input / output | |
| Hardware configuration | ||||
| Integrated power supply | Yes | Yes | Yes | |
| System power supply can be plugged in to left of IM | No | Yes; only with design with U-connectors | Yes | |
| Number of permissible power segments | 1 | 3 | 3 | |
| Rack | ||||
| ● Modules per rack, max. | 12; I/O modules | 30; I/O modules | 30; I/O modules | |
| Submodules | ||||
| ● Number of submodules per station, max. | 108; 9 submodules / I/O modules | 256 | ||
| Interfaces | ||||
| Number of PROFINET interfaces | 1; 2 ports (switch) RJ45 | 1 | 1 | |
| 1. Interface | ||||
| Interface types | ||||
| ● RJ 45 (Ethernet) | Yes | Yes | Yes | |
| ● Number of ports | 2 | 2 | 2 | |
| ● integrated switch | Yes | Yes | Yes | |
| ● BusAdapter (PROFINET) | No | |||
| Protocols | ||||
| ● PROFINET IO Device | Yes | Yes | Yes | |
| ● Open IE communication | Yes | Yes | Yes | |
| ● Media redundancy | Yes | Yes | Yes; PROFINET MRP | |
| Interface types | ||||
| RJ 45 (Ethernet) | ||||
| ● Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| ● 100 Mbps | Yes | Yes | Yes | |
| ● Autonegotiation | Yes | Yes | Yes | |
| ● Autocrossing | Yes | Yes | Yes | |
| Protocols | ||||
| PROFINET IO Device | ||||
| Services | ||||
| — IRT | No | Yes | Yes | |
| — PROFIenergy | No | No | No | |
| — Prioritized startup | No | Yes | Yes | |
| — Shared device | Yes | Yes | Yes | |
| — Number of IO Controllers with shared device, max. | 2 | 4 | 2 | |
| Redundancy mode | ||||
| ● PROFINET system redundancy (S2) | No | Yes | No | |
| — on S7-1500R/H | Yes | |||
| — on S7-400H | Yes; With GSDML file as of STEP 7 V5.5 SP3 | |||
| ● PROFINET system redundancy (R1) | No | No | ||
| ● H-Sync forwarding | Yes | |||
| Media redundancy | ||||
| — MRP | Yes | Yes | Yes | |
| — MRPD | No | Yes | No | |
| Open IE communication | ||||
| ● TCP/IP | Yes | Yes | Yes | |
| ● SNMP | Yes | Yes | Yes | |
| ● LLDP | Yes | Yes | Yes | |
| Isochronous mode | ||||
| Equidistance | No | Yes | Yes | |
| shortest clock pulse | 250 µs | 250 µs | ||
| max. cycle | 4 ms | 4 ms | ||
| Interrupts/diagnostics/status information | ||||
| Status indicator | Yes | Yes | Yes | |
| Alarms | Yes | Yes | Yes | |
| Diagnostics function | Yes | Yes | Yes | |
| Diagnostics indication LED | ||||
| ● RUN LED | Yes; green LED | Yes; green LED | Yes; green LED | |
| ● ERROR LED | Yes; red LED | Yes; red LED | Yes; red LED | |
| ● MAINT LED | Yes; Yellow LED | Yes; Yellow LED | Yes; Yellow LED | |
| ● Connection display LINK TX/RX | Yes; 2x green-yellow LEDs | Yes; 2x green-yellow LEDs | Yes; 2x green-yellow LEDs | |
| Potential separation | ||||
| between backplane bus and electronics | No | No | No | |
| between PROFINET and all other circuits | Yes; 1 500 V AC | Yes; 1 500 V AC | Yes | |
| between supply and all other circuits | No | No | No | |
| Permissible potential difference | ||||
| between different circuits | Safety extra low voltage SELV | |||
| Isolation | ||||
| Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | |
| Standards, approvals, certificates | ||||
| Network loading class | 2 | |||
| Ambient conditions | ||||
| Ambient temperature during operation | ||||
| ● horizontal installation, min. | -30 °C; From FS03 | -25 °C; from FS04 | -25 °C; From FS03 | |
| ● horizontal installation, max. | 60 °C | 60 °C | 60 °C | |
| ● vertical installation, min. | -30 °C; From FS03 | -25 °C; from FS04 | -25 °C; From FS03 | |
| ● vertical installation, max. | 40 °C | 40 °C | 40 °C | |
| Altitude during operation relating to sea level | ||||
| ● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | |
| connection method / header | ||||
| ET-Connection | ||||
| ● via BU/BA Send | No | No | ||
| Dimensions | ||||
| Width | 35 mm | 35 mm | 35 mm | |
| Height | 147 mm | 147 mm | 147 mm | |
| Depth | 129 mm | 129 mm | 129 mm | |
| Weights | ||||
| Weight, approx. | 236 g | 350 g | ||