Easy Modicon M200 – IO Transistor SINK+ Ethernet – Schneider PLC

$ 144.10$ 255.64

SKU: N/A

Specifications

Main
Part Number

TM200CE24U

TM200CE40U

range of product Easy Modicon M200 Easy Modicon M200
product or component type Logic controller Logic controller
[Us] rated supply voltage 24 V DC 24 V DC
discrete I/O number 24 40
discrete input number I2…I5: 4 fast input I2…I5: 4 fast input
I0, I1, I6, I7: 4 high speed input I0, I1, I6, I7: 4 high speed input
I8…I13: 6 regular input I8…I23: 16 regular input
discrete output number Q0…Q1: 2 fast output (PLS/PWM/PTO mode) Q0…Q1: 2 fast output (PLS/PWM/PTO mode)
Q2…Q9: 8 transistor output Q2…Q15: 14 transistor output
discrete input voltage 24 V 24 V
discrete input voltage type DC DC
discrete input current 7 mA for input 7 mA for input
discrete input logic Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2 Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2
discrete output voltage 24 V DC 24 V DC
discrete output current 0.5 A 0.5 A
discrete output type Transistor Transistor
discrete output logic Negative logic (sink) Negative logic (sink)
power consumption in W 10 W at 24 V DC (with max I/O) 10 W at 24 V DC (with max I/O)
Complementary
maximum number of I/O expansion module 4 with 64 discrete output(s) for relay output 4 with 64 discrete output(s) for relay output
4 with 138 discrete output(s) for transistor output 4 with 144 discrete output(s) for transistor output
supply voltage limits 20.4…28.8 V 20.4…28.8 V
inrush current 35 A 35 A
voltage state 1 guaranteed >= 15 V for input >= 15 V for input
voltage state 0 guaranteed <= 5 V for input <= 5 V for input
input impedance 3.3 kOhm for discrete input 3.3 kOhm for discrete input
response time 1 ms turn-on, Q0…Q9 terminal(s) for output 1 ms turn-on, Q0…Q15 terminal(s) for output
1 ms turn-off, Q0…Q9 terminal(s) for output 1 ms turn-off, Q0…Q15 terminal(s) for output
5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input
5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input
100 µs turn-off, I2…I5 terminal(s) for fast input 100 µs turn-off, I2…I5 terminal(s) for fast input
35 µs turn-on, I2…I5 terminal(s) for fast input 35 µs turn-on, I2…I5 terminal(s) for fast input
100 µs turn-off, I8…I13 terminal(s) for regular input 100 µs turn-off, I8…I13 terminal(s) for regular input
35 µs turn-on, I8…I13 terminal(s) for regular input 35 µs turn-on, I8…I13 terminal(s) for regular input
125 µs turn-off, I14…I23 terminal(s) for regular input
55 µs turn-on, I14…I23 terminal(s) for regular input
configurable filtering time 0 ms for input 0 ms for input
3 ms for input 3 ms for input
12 ms for input 12 ms for input
maximum current per output common 2 A at COM 0 0.083333333
3 A at COM 1 0.166666667
output frequency 100 kHz for fast output (PWM/PLS mode) at Q0…Q1 100 kHz for fast output (PWM/PLS mode) at Q0…Q1
maximum leakage current 0.1 mA for transistor output 0.1 mA for transistor output
maximum voltage drop <1 V <1 V
maximum tungsten load <12 W for output and fast output <12 W for output and fast output
protection type Overload and short-circuit protection at 3.8 A Overload and short-circuit protection at 3.8 A
reset time 1 s automatic reset 1 s automatic reset
memory capacity 512 byte internal flash for backup of programs 512 byte internal flash for backup of programs
data storage equipment 32 GB micro SD card (optional) 32 GB micro SD card (optional)
battery type BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)
backup time 3 years at 25 °C (by interruption of power supply) 3 years at 25 °C (by interruption of power supply)
execution time for 1 KInstruction 0.3 ms for event and periodic task 0.3 ms for event and periodic task
execution time per instruction 0.2 µs Boolean 0.2 µs Boolean
exct time for event task 60 µs response time 60 µs response time
clock drift <= 90 s/month at 25 °C <= 90 s/month at 25 °C
regulation loop Adjustable PID regulator up to 14 simultaneous loops Adjustable PID regulator up to 14 simultaneous loops
positioning functions PWM/PLS 2 channel(s) at 100 kHz PWM/PLS 2 channel(s) at 100 kHz
control signal type Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode)
Pulse/direction at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode)
Single phase at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode)
CW/CCW at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode)
counting input number 4 fast input (HSC mode) at 100 kHz 32 bits 4 fast input (HSC mode) at 100 kHz 32 bits
integrated connection type USB port with mini B USB 2.0 connector USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 1 with terminal block connector and RS485 interface
Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface
Isolated serial link serial 2 with terminal block connector and RS485 interface Isolated serial link serial 2 with terminal block connector and RS485 interface
transmission rate 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
12 Mbit/s for USB 12 Mbit/s for USB
10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP 10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP
communication port protocol USB port: USB – SoMachine-Network USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Ethernet Modbus TCP/IP: Modbus TCP/IP client/server Ethernet Modbus TCP/IP: Modbus TCP/IP client/server
local signalling 1 LED (green) for PWR 1 LED (green) for PWR
1 LED (green) for RUN 1 LED (green) for RUN
1 LED (red) for module error (ERR) 1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD) 1 LED (green) for SD card access (SD)
1 LED (red) for BAT 1 LED (red) for BAT
1 LED (green) for SL1 1 LED (green) for SL1
1 LED per channel (green) for I/O state 1 LED per channel (green) for I/O state
2 LEDs (green) for communication (LK/ACT 10/100) 2 LEDs (green) for communication (LK/ACT 10/100)
electrical connection Mini B USB 2.0 connectorfor a programming terminal Mini B USB 2.0 connectorfor a programming terminal
RJ45 connectorfor connecting Ethernet network RJ45 connectorfor connecting Ethernet network
removable screw terminal blockfor inputs removable screw terminal blockfor inputs
removable screw terminal blockfor outputs removable screw terminal blockfor outputs
removable screw terminal block, 3 terminal(s) for connecting the 24 V DC power supply removable screw terminal block, 3 terminal(s) for connecting the 24 V DC power supply
removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 4 terminal(s) for connecting the serial link1
maximum cable distance between devices Unshielded cable: <50 m for input Unshielded cable: <50 m for input
Shielded cable: <10 m for fast input Shielded cable: <10 m for fast input
Shielded cable: <10 m for high speed input Shielded cable: <10 m for high speed input
Unshielded cable: <150 m for output Unshielded cable: <150 m for output
insulation Non-insulated between inputs Non-insulated between inputs
Between input and internal logic at 500 V AC Between input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC
Between input groups at 500 V AC Between input groups at 500 V AC
Between output and internal logic at 500 V AC Between output and internal logic at 500 V AC
Between output groups at 500 V AC Between output groups at 500 V AC
Between supply and internal logic at 500 V DC Between supply and internal logic at 500 V DC
Marking CE CE
mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
Height 90 mm 90 mm
Depth 70 mm 70 mm
width 130 mm 175 mm
Net weight 0.391 kg 0.483 kg
Environment
IP degree of protection IP20 with protective cover in place IP20 with protective cover in place
product certifications IACS E10 CE
cULus EAC
RCM
CSA
Standards EN/IEC 61131-2 EN/IEC 61131-2
EN/IEC 61010-2-201 EN/IEC 61010-2-201
electromagnetic compatibility Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3
Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8 Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5
Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6
Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011
Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011
Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
shock resistance 15 gn for 11 ms 15 gn for 11 ms
30 gn for 6 ms 30 gn for 6 ms
immunity to microbreaks 2 ms 2 ms
vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on symmetrical DIN rail
1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical DIN rail
3.5 mm at 5…8.7 Hz on panel mounting 3.5 mm at 5…8.7 Hz on panel mounting
2 gn at 8.7…150 Hz on panel mounting 2 gn at 8.7…150 Hz on panel mounting
relative humidity 10…95 %, without condensation (in operation) 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage) 10…95 %, without condensation (in storage)
ambient air temperature for operation 0…55 °C (horizontal installation) 0…55 °C (horizontal installation)
Ambient air temperature for storage -25…70 °C -25…70 °C
pollution degree <= 2 <= 2
Operating altitude 0…2000 m 0…2000 m
Storage altitude 0…3000 m 0…3000 m
Packing Units
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 13.6 cm 9 cm
Package 1 Width 9 cm 18.3 cm
Package 1 Length 13.8 cm 13.6 cm
Package 1 Weight 612 g 731.5 g
Unit Type of Package 2 S03 S03
Number of Units in Package 2 12 12
Package 2 Height 30 cm 30 cm
Package 2 Width 30 cm 30 cm
Package 2 Length 40 cm 40 cm
Package 2 Weight 7944 g 9298 g
Unit Type of Package 3 P12 P12
Number of Units in Package 3 288 288
Package 3 Height 80 cm 95 cm
Package 3 Width 120 cm 80 cm
Package 3 Length 105 cm 120 cm
Package 3 Weight 199656 g 232152 g

 

Weight N/A
Dimensions N/A

Related products