SICK 1079119 LUT9 UV Luminescence Sensor, PNP and IO-Link

USD 1,671.02

LUT9U-P124L uses 375 nm UV excitation and a 415–425 nm receiving band, with 10–40 mm working range, PNP switching, teach-in and optional IO-Link setup.

SKU SICK-1079119 Category
SICK LUT9

SICK LUT9U-P124L UV Luminescence Sensor

BrandSICK
Model IdentifierLUT9U-P124L
Official Part Number1079119

Technical Overview

The SICK LUT9U-P124L is a luminescence sensor using 375 nm ultraviolet LED excitation and a 415–425 nm receiving band. Long-side emission produces a vertical 3 × 9 mm spot, with a 10–40 mm working range and a stated 20 mm sensing distance measured from the leading lens edge. A teach-in button and rotary selector establish the luminescence threshold, while the green bar graph displays luminescence intensity in RUN. The PNP output supports light/dark selection through teaching or IO-Link. IO-Link V1.0 provides switching and measurement process data. The four-pin M12 connector, zinc die-cast housing and IP67 protection support operation from −10 to +55 °C.

375 nm UV luminescence sensor with 415–425 nm receiving band, 10–40 mm working range, PNP switching, teach-in, IO-Link V1.0 and M12 connection.

Key Features

  • 375 nm ultraviolet LED luminescence sensing
  • 415–425 nm receiving band with background-luminescence suppression filter
  • 10–40 mm working range; 20 mm stated sensing distance from leading lens edge
  • Long-side emission; vertical 3 × 9 mm light spot
  • Teach-in button and rotary selector; green bar graph and yellow output LED
  • PNP light switching; light/dark selection through teach-in or IO-Link
  • 0.5 / 2.5 / 6.5 kHz switching; 1 ms / 200 µs / 75 µs response settings
  • Adjustable switch-off delay 0 / 10 / 20 ms; default 0 ms
  • IO-Link V1.0; 2.3 ms cycle; switching and measurement process data
  • M12 four-pin connector; zinc die-cast housing; IP67; −10 to +55 °C operation

Detect a suitable fluorescent mark under UV excitation, teaching its signal against the actual background and checking the material’s emission against the receiving band.

Technical Specification Matrix

ParameterValue
Functional principleUV-excited luminescence sensing
Light sourceUltraviolet LED
Wavelength375 nm
LED service lifeAverage 100,000 h at +25 °C
Light emissionLong side of housing
Light spot size3 × 9 mm
Light spot directionVertical
Working range10–40 mm
Sensing distance20 mm from leading edge of lens
Receiving band415–425 nm
Receiving filterBackground-luminescence suppression filter
AdjustmentTeach-in button and rotary selector; IO-Link optional for adjustment
Static teachingTeach mark and background separately; bar graph shows detection reliability
RUN displayBar graph shows luminescence intensity regardless of threshold setting
IndicatorsYellow: switching output; green bar graph: signal, with left-hand power-on LED
Digital outputPNP; maximum output current 100 mA
Switching modeLight switching; light/dark selection through teach-in or IO-Link
Switching frequency0.5 kHz / 2.5 kHz / 6.5 kHz; at 1:1 light/dark ratio without timer stage
Response time1 ms / 200 µs / 75 µs for the corresponding listed frequency settings
Switch-off delay0 ms / 10 ms / 20 ms, adjustable; 0 ms default
IO-LinkV1.0; 2.3 ms cycle
IO-Link identificationVendorID 26; DeviceID 0x80000F / 8388623
IO-Link process dataBit 0=QL1 switching signal; bits 1–5 empty; bits 6–15 measurement value
ConnectionM12 four-pin male connector; rotatable up to 90°
Pin assignment1 BN=L+; 2 WH=Q̅; 3 BU=M; 4 BK=Q/C (CD-309)
Power supply10–30 V DC, limit values; short-circuit-protected network maximum 8 A
Ripple<5 Vpp; remain within supply tolerances
Current consumption<100 mA without load
Protection classII; reference voltage 50 V DC
Circuit protectionSupply reverse-polarity protection; output Q short-circuit protection; interference pulse suppression
Housing materialZinc die-cast
MountingM5 threaded mounting holes, 5.5 mm deep
IP ratingIP67
Operating temperature−10 to +55 °C
Storage temperature−25 to +75 °C
Shock resistanceAccording to IEC 60068
Physical Weight (kg)0.4

Industrial Applications

1. Providing a fluorescent web-registration reference

A packaging web can carry a fluorescent registration mark through the UV light spot at a controlled distance. The material must respond to 375 nm excitation with emission suitable for the 415–425 nm receiving band. Teaching separates mark and background, and external registration logic uses the PNP switching transition after setup verifies web speed, spot orientation and selected timing.

Problem Solved

A fluorescent-mark reference helps external registration logic locate repeated web positions when the chosen mark and background produce a usable luminescence difference in the specified receiving band.

Fluorescent registration UV excitation PNP switching

2. Checking fluorescent coating at a presented location

An inspection fixture can present a known coating location within the working range after application. A suitable fluorescent coating produces a signal under the specified UV excitation, and representative coated and uncoated samples establish the threshold. External inspection logic samples the PNP output after positioning, while commissioning checks material emission, coverage at the monitored spot and background luminescence.

Problem Solved

A local fluorescent-presence reference helps external inspection logic identify a missing coating condition at one monitored location, when representative samples establish a reliable difference from the background.

Coating presence Presented inspection Luminescence threshold

3. Comparing luminescence signal during repeated presentations

A process station can repeatedly present the same fluorescent feature at a controlled distance and orientation. IO-Link supplies the measurement-value field as well as the switching signal, allowing external monitoring logic to compare readings with an established process reference. Setup controls material, background and geometry because the reading represents the detected optical condition and requires application-specific interpretation.

Problem Solved

A transmitted luminescence reading helps external monitoring logic compare repeated presentations against a process reference, supporting investigation of optical changes without assuming a calibrated chemical-concentration measurement.

Signal comparison IO-Link measurement Process reference
Select your currency