SCALANCE XB-000 Unmanaged Industrial Ethernet Switch – Siemens Industrial Ethernet
$ 135.37 – $ 481.80
SKU: N/A
The unmanaged Industrial Ethernet switches of the SCALANCE XB-000 line enable cost-effective solutions for setting up small, electrical/optical star or line topologies with switching functionality in machines or plant units. The enclosure is designed for space-saving installation in a control cabinet on a standard rail.
Siemens Industrial Ethernet XB-000 Product Specifications:
Article number | 6GK5005-0BA00-1AB2 | 6GK5005-0GA10-1AB2 | |
product type designation | SCALANCE XB005 | SCALANCE XB005G | |
transfer rate | |||
transfer rate | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s | |
interfaces for communication integrated | |||
number of electrical connections | |||
● for network components or terminal equipment | 5; RJ45 | 5; RJ45 | |
number of 100 Mbit/s SC ports | |||
● for multimode | 0 | 0 | |
● for single mode (LD) | |||
interfaces other | |||
number of electrical connections | |||
● for power supply | 1 | 1 | |
type of electrical connection | |||
● for power supply | 3-pole terminal block | 3-pole terminal block | |
supply voltage, current consumption, power loss | |||
type of voltage 1 of the supply voltage | DC | DC | |
● supply voltage 1 rated value | 24 V | 24 V | |
● power loss [W] 1 rated value | 1.68 W | 10.5 W | |
● supply voltage 1 rated value | 19.2 … 28.8 V | 19.2 … 28.8 V | |
● consumed current 1 maximum | 0.07 A | 0.44 A | |
● type of electrical connection 1 for power supply | 3-pole terminal block | 3-pole terminal block | |
● product component 1 fusing at power supply input | Yes | Yes | |
● fuse protection type 1 at input for supply voltage | 0.6 A / 60 V | 0.6 A / 60 V | |
type of voltage 2 of the supply voltage | |||
● supply voltage 2 rated value | 19.2 … 28.8 V | ||
ambient conditions | |||
ambient temperature | |||
● during operation | -10 … +60 °C | -10 … +60 °C | |
● during storage | -40 … +80 °C | -40 … +80 °C | |
● during transport | -40 … +80 °C | -40 … +80 °C | |
relative humidity | |||
● at 25 °C without condensation during operation maximum | 95 % | 95 % | |
protection class IP | IP20 | IP20 | |
design, dimensions and weights | |||
design | Box | Box | |
width | 45 mm | 45 mm | |
height | 100 mm | 100 mm | |
depth | 87 mm | 87 mm | |
net weight | 0.165 kg | 0.172 kg | |
fastening method | |||
● 35 mm top hat DIN rail mounting | Yes | Yes | |
● wall mounting | Yes | Yes | |
● S7-1500 rail mounting | No | No | |
product functions management, configuration, engineering | |||
product function | |||
● multiport mirroring | No | No | |
● CoS | Yes | Yes | |
PROFINET conformity class | A | A | |
product function switch-managed | No | No | |
product functions redundancy | |||
product function | |||
● Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes | Yes | |
● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA) | No | No | |
standards, specifications, approvals | |||
standard | |||
● for FM | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 | |
● for safety from CSA and UL | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | |
● for emitted interference | EN 61000-6-4 (Class A) | EN 61000-6-4 (Class B) | |
● for interference immunity | EN 61000-6-2 | EN 61000-6-2 | |
MTBF | 241 y | 139 y | |
reference code | |||
● according to IEC 81346-2 | KF | KF | |
● according to IEC 81346-2:2019 | KFE | KFE | |
standards, specifications, approvals CE | |||
certificate of suitability CE marking | Yes | Yes | |
standards, specifications, approvals hazardous environments | |||
standard for hazardous zone | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | EN 60079-0:2009, EN60079-15:2010, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X | |
certificate of suitability | |||
● CCC for hazardous zone according to GB standard | Yes | Yes | |
standards, specifications, approvals other | |||
certificate of suitability | EN 61000-6-2, EN 61000-6-4 | EN 61000-6-2, EN 61000-6-4 | |
● C-Tick | Yes | Yes | |
● KC approval | Yes | Yes |
Weight | N/A |
---|---|
Dimensions | N/A |