RE13-SAC – Non-Contact Safety Switches – SICK Sensor Accessories
$ 69.92
SKU: SICK 1059503
Part Number: 1059503
Non-contact safety switches: RE13-SAC
OEM Spec Ref
Features
System part | Sensor with actuator |
Sensor principle | Magnetic |
Number of N/O contacts | 2 |
Number of N/C contacts | 0 |
Number of signaling contacts | 0 |
Safe switch on distance Sao | 7 mm |
Safe switch off distance Sar | 20 mm |
Active sensor surfaces | 1 |
Actuation directions | 3 |
Safety-related parameters
B10d parameter | 2 x 107 switching cycles (with small load) |
Type | Type 4 (EN ISO 14119) |
Actuator coding level | Low coding level (EN ISO 14119) |
Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. |
Functions
Safe series connection | With Flexi Loop (with diagnostics) |
Interfaces
Connection type | Plug connector, M8, 4-pin |
Electrical data
Type of output | Reed contacts |
Switching voltage | ≤ 30 V DC |
Switching current | ≤ 100 mA |
Mechanical data
Design | Rectangular |
Dimensions (W x H x D) | 26 mm x 36 mm x 13 mm |
Weight | 0.1 kg |
Housing material | VISTAL® |
Enclosure rating | IP67 (IEC 60529) |
Ambient operating temperature | –30 °C … +60 °C |
Storage temperature | –30 °C … +60 °C |
Vibration resistance | 10 Hz … 55 Hz, 1 mm (EN 60947-5-3) |
Shock resistance | 30 g, 11 ms (EN 60947-5-3) |
Weight | 0.059 kg |
---|---|
Dimensions | 8.0 × 2.0 × 11.5 cm |