Analog inputs record process signals such as pressure or temperature and forward them in digitalized format (16-bit format) to the PLC. They are suitable for measuring voltage, current (2-wire and 4-wire transmitters), resistance, resistance thermometers and the connection of thermocouples.
Analog outputs convert a 16-bit digital value into a current or a voltage and output this to the process. They are suitable, for example, for controlling proportional valves or small servo drives.
All I/O devices have configurable parameters and diagnostic functions and can thus be freely adapted to the respective process requirements.
Article number | 6ES7144-6KD00-0AB0 |
ET200eco PN, 8AI; 4 U/I; 4 RTD/TC 8xM12 | |
General information | |
HW functional status | |
Firmware version | |
● FW update possible | |
Vendor identification (VendorID) | 002AH |
Device identifier (DeviceID) | 0306H |
Manufacturer ID according to ODVA (VendorID) | |
Device ID according to ODVA (Product code) | |
Product function | |
● I&M data | |
● Isochronous mode | |
● Prioritized startup | |
● Measuring range scalable | |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | |
● PROFINET from GSD version/GSD revision | |
● Multi Fieldbus Configuration Tool (MFCT) | |
Operating mode | |
● MSI | |
CiR – Configuration in RUN | |
Calibration possible in RUN | |
Supply voltage | |
Rated value (DC) | 24 V |
Reverse polarity protection | Yes |
power supply according to NEC Class 2 required | Yes |
Load voltage 1L+ | |
● Rated value (DC) | |
● permissible range, lower limit (DC) | |
● permissible range, upper limit (DC) | |
● Reverse polarity protection | |
Input current | |
Current consumption (rated value) | |
Current consumption, typ. | 110 mA |
from load voltage 1L+ (unswitched voltage) | |
from load voltage 2L+, max. | |
Encoder supply | |
Number of outputs | 4 |
24 V encoder supply | |
● Short-circuit protection | Yes; Electronic at 1.4 A |
● Output current, max. | 1 A |
Power loss | |
Power loss, typ. | 2.8 W |
Address area | |
Address space per module | |
● Inputs | |
Hardware configuration | |
Submodules | |
● Number of configurable submodules, max. | |
Analog inputs | |
Number of analog inputs | 8 |
● For voltage/current measurement | 4 |
● For voltage measurement | |
● For resistance/resistance thermometer measurement | 4 |
● For thermocouple measurement | |
permissible input voltage for voltage input (destruction limit), max. | 28.8 V permanent, 35 V for max. 500 ms |
Constant measurement current for resistance-type transmitter, typ. | |
Cycle time (all channels), min. | |
Technical unit for temperature measurement adjustable | |
Input ranges (rated values), voltages | |
● 0 to +10 V | Yes |
● 1 V to 5 V | Yes |
● -10 V to +10 V | Yes |
● -80 mV to +80 mV | Yes |
— Input resistance (-80 mV to +80 mV) | |
Input ranges (rated values), currents | |
● 0 to 20 mA | Yes |
● -20 mA to +20 mA | Yes |
● 4 mA to 20 mA | Yes |
Input ranges (rated values), thermocouples | |
● Type B | |
— Input resistance (Type B) | |
● Type C | |
— Input resistance (Type C) | |
● Type E | Yes |
— Input resistance (Type E) | |
● Type J | Yes |
— Input resistance (type J) | |
● Type K | Yes |
— Input resistance (Type K) | |
● Type L | |
— Input resistance (Type L) | |
● Type N | Yes |
— Input resistance (Type N) | |
● Type R | |
— Input resistance (Type R) | |
● Type S | |
— Input resistance (Type S) | |
● Type T | |
— Input resistance (Type T) | |
● Type U | |
— Input resistance (Type U) | |
Input ranges (rated values), resistance thermometer | |
● Ni 100 | Yes |
— Input resistance (Ni 100) | |
● Ni 1000 | Yes |
— Input resistance (Ni 1000) | |
● Ni 120 | Yes |
— Input resistance (Ni 120) | |
● Ni 200 | Yes |
— Input resistance (Ni 200) | |
● Ni 500 | Yes |
— Input resistance (Ni 500) | |
● Pt 100 | Yes |
— Input resistance (Pt 100) | |
● Pt 1000 | Yes |
— Input resistance (Pt 1000) | |
● Pt 200 | Yes |
— Input resistance (Pt 200) | |
● Pt 500 | Yes |
— Input resistance (Pt 500) | |
Input ranges (rated values), resistors | |
● 0 to 150 ohms | Yes |
— Input resistance (0 to 150 ohms) | |
● 0 to 300 ohms | Yes |
— Input resistance (0 to 300 ohms) | |
● 0 to 600 ohms | Yes |
— Input resistance (0 to 600 ohms) | |
● 0 to 3000 ohms | Yes |
— Input resistance (0 to 3000 ohms) | |
● 0 to 6000 ohms | |
— Input resistance (0 to 6000 ohms) | |
Thermocouple (TC) | |
Temperature compensation | |
— parameterizable | Yes |
— internal temperature compensation | Yes |
— external temperature compensation with Pt100 | |
— external temperature compensation with compensations socket | Yes |
— dynamic reference temperature value | |
— for definable comparison point temperature | |
— fixed reference temperature | |
Cable length | |
● shielded, max. | 30 m |
Analog value generation for the inputs | |
Analog value display | SIMATIC S7 format |
Measurement principle | integrating |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 16 bit |
● Integration time, parameterizable | Yes |
● Integration time (ms) | 2/16.67/20/100 ms |
● Basic conversion time, including integration time (ms) | |
— additional conversion time for wire-break monitoring | |
● Interference voltage suppression for interference frequency f1 in Hz | 500 / 60 / 50 / 10 Hz |
● Conversion time (per channel) | 4 / 19 / 22 / 102 ms |
Smoothing of measured values | |
● parameterizable | Yes |
● Step: None | Yes; 1x cycle time |
● Step: low | Yes; 4x cycle time |
● Step: Medium | Yes; 16x cycle time |
● Step: High | Yes; 64x cycle time |
Encoder | |
Number of connectable encoders, max. | 8 |
Connection of signal encoders | |
● for voltage measurement | Yes |
● for current measurement as 2-wire transducer | Yes |
● for current measurement as 4-wire transducer | Yes |
● for resistance measurement with two-wire connection | Yes |
● for resistance measurement with three-wire connection | Yes |
● for resistance measurement with four-wire connection | Yes |
Errors/accuracies | |
Linearity error (relative to input range), (+/-) | 0.01 % |
Temperature error (relative to input range), (+/-) | U: 0.0035%/°C; I:0.006%/°C; RTD: 0.0005%/°C; TC: 0.0035%/°C |
Crosstalk between the inputs, min. | 85 dB |
Crosstalk between the inputs, max. | |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.008 % |
Temperature error of internal compensation | |
Operational error limit in overall temperature range | |
● Voltage, relative to input range, (+/-) | |
● Resistance, relative to input range, (+/-) | |
● Resistance thermometer, relative to input range, (+/-) | |
● Thermocouple, relative to input range, (+/-) | |
Basic error limit (operational limit at 25 °C) | |
● Voltage, relative to input range, (+/-) | |
● Resistance, relative to input range, (+/-) | |
● Resistance thermometer, relative to input range, (+/-) | |
● Thermocouple, relative to input range, (+/-) | |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |
● Series mode interference (peak value of interference < rated value of input range), min. | 46 dB |
● Common mode interference, min. | 70 dB |
Interference voltage suppression for f = n x (f1 +/- 0.5 %), f1 = interference frequency | |
● Series mode interference (peak value of interference < rated value of input range), min. | |
Interfaces | |
Transmission procedure | 100BASE-TX |
Number of PROFINET interfaces | 1 |
1. Interface | |
Interface type | |
Interface types | |
● M12 port | Yes |
● Number of ports | |
● integrated switch | Yes |
Protocols | |
● PROFINET IO Device | |
● Open IE communication | |
Interface types | |
M12 port | |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Transmission rate, max. | 100 Mbit/s |
Protocols | |
Supports protocol for PROFINET IO | Yes |
PROFINET CBA | No |
PROFIsafe | No |
EtherNet/IP | |
Modbus TCP | |
PROFINET IO Device | |
Services | |
— IRT | |
— IRT with the option “high flexibility” | Yes |
— Prioritized startup | Yes |
— Shared device | |
— Number of IO Controllers with shared device, max. | |
Redundancy mode | |
● PROFINET system redundancy (S2) | |
— on S7-1500R/H | |
— on S7-400H | |
● PROFINET system redundancy (R1) | |
● H-Sync forwarding | |
Media redundancy | |
— MRP | Yes |
EtherNet/IP | |
Services | |
— CIP Implicit Messaging | |
— CIP Explicit Messaging | |
— CIP Safety | |
— Shared device | |
— Number of scanners with shared device, max. | |
Updating times | |
— Requested Packet Interval (RPI) | |
Redundancy mode | |
— DLR (Device Level Ring) | |
Address area | |
— Address space per module, max. | |
— LargeForwardOpen (Class3) | |
Modbus TCP | |
Services | |
— read coils (code=1) | |
— read discrete inputs (code=2) | |
— Read Holding Registers (Code=3) | |
— write single coil (code=5) | |
— write multiple coils (code=15) | |
— Write Multiple Registers (Code=16) | |
— Parameter change by master | |
— Modbus TCP Security Protocol | |
Address space per station | |
— Address space per station, max. | |
— Access-consistent address space | |
Updating time | |
— I/O request interval | |
Connections | |
— Number of connections per slave | |
Open IE communication | |
● TCP/IP | No |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
● ping | Yes |
● ARP | Yes |
Interrupts/diagnostics/status information | |
Diagnostics function | Yes |
Alarms | |
● Diagnostic alarm | Yes |
● Maintenance interrupt | |
● Limit value alarm | |
Diagnoses | |
● Diagnostic information readable | Yes |
● Monitoring the supply voltage | Yes; green “ON” LED |
— parameterizable | |
● Wire-break | |
● Short-circuit encoder supply | Yes; per module |
● Group error | Yes; Red/yellow “SF/MT” LED |
● Overflow/underflow | Yes |
Diagnostics indication LED | |
● RUN LED | |
● ERROR LED | |
● MAINT LED | |
● NS LED | |
● MS LED | |
● IO LED | |
● Channel status display | |
● for channel diagnostics | |
● Connection display LINK TX/RX | |
Potential separation | |
between the load voltages | Yes |
between load voltage and all other switching components | No |
between Ethernet and electronics | Yes |
Potential separation channels | |
● between the channels | No |
● between the channels and the power supply of the electronics | |
Permissible potential difference | |
Between the inputs and MANA (UCM) | 10 Vpp AC |
Isolation | |
tested with | |
● 24 V DC circuits | 707 V DC (type test) |
● Test voltage for interface, rms value [Vrms] | 1 500 V; According to IEEE 802.3 |
Degree and class of protection | |
IP degree of protection | IP65/67 |
Standards, approvals, certificates | |
Suitable for applications according to AMS 2750 | Yes; Declaration of Conformity, see online support entry 109757262 |
Suitable for applications according to CQI-9 | Yes; Based on AMS 2750 E |
Ambient conditions | |
Ambient temperature during operation | |
● min. | |
● max. | |
Altitude during operation relating to sea level | |
● Ambient air temperature-barometric pressure-altitude | |
connection method / header | |
Design of electrical connection | 4/5-pin M12 circular connectors |
Design of electrical connection for the inputs and outputs | |
Design of electrical connection for supply voltage | |
Dimensions | |
Width | 60 mm |
Height | 175 mm |
Depth | 49 mm |
Weights | |
Weight, approx. | 930 g |
Weight | 0.959 kg |
---|---|
Dimensions | 7.3 × 20.3 × 5.8 cm |