$ 279.76 – $ 393.07Price range: $ 279.76 through $ 393.07
The IM 154-1 DP and IM 154-2 DP High Feature interface modules are configured using STEP 7 V5.3 SP3. A hardware support package is available for STEP 7 V5.3 SP2 and higher.
Integration into older versions is possible via GSD.
| Article number | 6ES7154-1AA01-0AB0 | 6ES7154-2AA01-0AB0 |
| ET 200pro, IM 154-1 DP | ET 200pro, IM154-2 DP HF | |
| General information | ||
| Product type designation | IM 154-1 DP | IM 154-2 DP HF |
| Vendor identification (VendorID) | 8118H | 8119H |
| Supply voltage | ||
| Rated value (DC) | 24 V | 24 V |
| Reverse polarity protection | Yes; against destruction | Yes; against destruction |
| Short-circuit protection | Yes; over exchangeable fuses | Yes; over exchangeable fuses |
| power supply according to NEC Class 2 required | No | No |
| Load voltage 2L+ | ||
| ● Rated value (DC) | 24 V | 24 V |
| ● Reverse polarity protection | Yes; against destruction | Yes; against destruction |
| Input current | ||
| from supply voltage 1L+, max. | 200 mA | 200 mA |
| Power loss | ||
| Power loss, typ. | 5 W | 5 W |
| Address area | ||
| Addressing volume | ||
| ● Inputs | 244 byte | 244 byte |
| ● Outputs | 244 byte | 244 byte |
| Interfaces | ||
| Interfaces/bus type | PROFIBUS DP | PROFIBUS DP |
| Interface types | ||
| RS 485 | ||
| ● Transmission rate, max. | 12 Mbit/s | 12 Mbit/s |
| ● automatic detection of transmission rate | Yes | Yes |
| Protocols | ||
| PROFIBUS DP | ||
| Services | ||
| — SYNC capability | Yes | Yes |
| — FREEZE capability | Yes | Yes |
| — Direct data exchange (slave-to-slave communication) | Yes | Yes |
| Interrupts/diagnostics/status information | ||
| Alarms | ||
| ● Diagnostic alarm | Yes; Parameterizable | Yes; Parameterizable |
| ● Hardware interrupt | Yes; Parameterizable | Yes; Parameterizable |
| Diagnostics indication LED | ||
| ● For load voltage monitoring | Yes | Yes |
| ● Bus fault BF (red) | Yes | Yes |
| ● Group error SF (red) | Yes | Yes |
| ● Monitoring 24 V voltage supply ON (green) | Yes | Yes |
| Parameter | ||
| DPV1 operation | possible | possible |
| Swapping interrupt | Parameterizable | Parameterizable |
| Startup if setpoint not equal to actual configuration | Parameterizable | Parameterizable |
| Hot swapping of modules | possible | possible |
| Potential separation | ||
| between supply voltage and electronics | Yes | Yes |
| Isolation | ||
| Isolation tested with | 707 V DC (type test) | 707 V DC (type test) |
| Degree and class of protection | ||
| IP degree of protection | IP65/67 | IP65/67 |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● min. | -25 °C | -25 °C |
| ● max. | 55 °C | 55 °C |
| Ambient temperature during storage/transportation | ||
| ● min. | -40 °C | -40 °C |
| ● max. | 70 °C | 70 °C |
| Dimensions | ||
| Width | 90 mm | 90 mm |
| Height | 130 mm | 130 mm |
| Depth | 60 mm | 60 mm |
| Weights | ||
| Weight, approx. | 375 g | 375 g |