Article number | 6ES7136-6RA00-0BF0 |
ET 200SP, F-RQ 1x24VDC/24..230VAC/5A ST | |
General information | |
Product type designation | F-RQ 24 … 48VDC/24 … 230VAC/5A ST |
usable BaseUnits | BU type F0 |
Color code for module-specific color identification plate | CC42 |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V13 |
● STEP 7 configurable/integrated from version | V5.5 SP4 and higher |
● PROFINET from GSD version/GSD revision | V2.31 |
Supply voltage | |
Rated value (DC) | 24 V; Coil voltage |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
power supply according to NEC Class 2 required | No |
Power | |
Power available from the backplane bus | 100 mW |
Power loss | |
Power loss, typ. | 1 W |
Address area | |
Address space per module | |
● Inputs | 1 byte |
Hardware configuration | |
Automatic encoding | Yes |
● Mechanical coding element | Yes |
● Type of mechanical coding element | type C |
Digital outputs | |
Type of digital output | Relays |
Number of digital outputs | 1 |
Limitation of inductive shutdown voltage to | No |
Controlling a digital input | Yes |
Switching capacity of the outputs | |
● with resistive load, max. | 5 A |
● on lamp load, max. | 25 W |
Switching frequency | |
● with resistive load, max. | 2 Hz |
● with inductive load, max. | 0.1 Hz; See data in manual |
● with inductive load (acc. to IEC 60947-5-1, DC13), max. | 0.1 Hz |
● with inductive load (acc. to IEC 60947-5-1, AC15), max. | 2 Hz |
Total current of the outputs (per module) | |
horizontal installation | |
— up to 40 °C, max. | 5 A; note derating data in the manual |
— up to 50 °C, max. | 4 A; note derating data in the manual |
— up to 60 °C, max. | 3 A; note derating data in the manual |
vertical installation | |
— up to 50 °C, max. | 3 A; note derating data in the manual |
Relay outputs | |
● Number of relay outputs | 1; 2 NO contacts |
● Rated supply voltage of relay coil L+ (DC) | 24 V |
● Current consumption of relays (coil current of all relays), max. | 70 mA |
● external protection for relay outputs | yes; 6 A, see data in manual |
● Relay approved acc. to UL 508 | Yes; Pilot Duty B300, R300 |
Switching capacity of contacts | |
— with inductive load, max. | see additional description in the manual |
— with resistive load, max. | see additional description in the manual |
— Thermal continuous current, max. | 5 A |
— Switching current, min. | 1 mA |
— Switching current after exceeding 300 mA, min. | 10 mA |
— Switching current after exceeding 300 mA, max. | 5 A |
— Rated switching voltage (DC) | 24 V |
— Rated switching voltage (AC) | 230 V |
Cable length | |
● shielded, max. | 500 m; for load contacts |
● unshielded, max. | 300 m; for load contacts |
● Control cable (input), max. | 10 m |
Interrupts/diagnostics/status information | |
Diagnostics function | Yes |
Diagnostics indication LED | |
● RUN LED | Yes; green/red DIAG LED |
● Channel status display | Yes; green LED |
Potential separation | |
Potential separation channels | |
● between the channels | Yes; for SELV / PELV only |
● between the channels and backplane bus | Yes |
● between the channels and the power supply of the electronics | Yes |
Permissible potential difference | |
between channels and backplane bus/supply voltage | 250 V AC (reinforced insulation) |
Isolation | |
Isolation tested with | 2 545 V DC/2 s (routine test) |
Overvoltage category | III |
tested with | |
● between channels and backplane bus/supply voltage | DC 2 545 V 2 s (routine test), impulse voltage test DC 7 200 V / 5 positive and 5 negative pulses (type test) |
● between backplane bus and supply voltage | 707 V DC (type test) |
Standards, approvals, certificates | |
Suitable for safety functions | Yes |
Highest safety class achievable in safety mode | |
● Performance level according to ISO 13849-1 | PLe |
● Category according to ISO 13849-1 | 4 |
● SIL acc. to IEC 61508 | SIL 3 |
Probability of failure (for service life of 20 years and repair time of 100 hours) | |
— Low demand mode: PFDavg in accordance with SIL2 | < 1.00E-04, function test 1x per year |
— Low demand mode: PFDavg in accordance with SIL3 | < 1.00E-05, function test 1x per month |
— High demand/continuous mode: PFH in accordance with SIL2 | < 1.00E-08 1/h, function test 1x per year |
— High demand/continuous mode: PFH in accordance with SIL3 | < 6.00E-09 1/h, function test 1x per month |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 50 °C |
Dimensions | |
Width | 20 mm |
Height | 73 mm |
Depth | 58 mm |
Weights | |
Weight, approx. | 56 g |
Weight | 0.07 kg |
---|---|
Dimensions | 6.8 × 8 × 2.9 cm |