SIMATIC S7-300 CPU 317TF-3 PN/DP – Siemens PLC
$ 8,688.14
SKU: 6ES7317-7UL10-0AB0
The CPU 317TF-3 PN/DP is a controller that enables motion control, standard and safety tasks to be performed in one controller. It is used in machines where a controller with a large program memory and high processing speed is confronted by motion control requirements at the same time.
Siemens PLC S7-300 Product Specifications:
Article number | 6ES7317-7UL10-0AB0 |
CPU317TF-3 PN/DP, 1,5 MB | |
General information | |
HW functional status | 1 |
Firmware version | CPU: V3.2; integrated technology V4.1.5 |
Product function | |
● Isochronous mode | Yes; Via PROFIBUS DP or PROFINET interface |
Engineering with | |
● Programming package | STEP 7 V5.5 SP2 or higher; S7-Technology option package V4.2 SP3 or higher, Distributed Safety V5.4 SP5 or higher, S7-F Configuration Pack V5.5 SP10 or higher |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
external protection for power supply lines (recommendation) | 2 A min. |
Load voltage L+ | |
● Rated value (DC) | 24 V |
● Reverse polarity protection | Yes |
Digital outputs | |
— Rated value (DC) | 24 V; 2L+ |
— Reverse polarity protection | No; 2L+ |
Input current | |
Current consumption (rated value) | 1 100 mA |
Current consumption (in no-load operation), typ. | 270 mA |
Inrush current, typ. | 6.5 A |
I²t | 1 A²·s |
Power loss | |
Power loss, typ. | 8.5 W |
Memory | |
Work memory | |
● integrated | 1 536 kbyte |
● expandable | No |
Load memory | |
● Plug-in (MMC) | Yes |
● Plug-in (MMC), max. | 8 Mbyte |
● Data management on MMC (after last programming), min. | 10 y |
Backup | |
● present | Yes; Guaranteed by MMC (maintenance-free) |
● without battery | Yes; Program and data |
CPU processing times | |
for bit operations, typ. | 0.025 µs |
for word operations, typ. | 0.03 µs |
for fixed point arithmetic, typ. | 0.04 µs |
for floating point arithmetic, typ. | 0.16 µs |
CPU-blocks | |
Number of blocks (total) | 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB | |
● Number, max. | 2 048; Number range: 1 to 16000 |
● Size, max. | 64 kbyte |
FB | |
● Number, max. | 2 048; Number range: 0 to 7999 |
● Size, max. | 64 kbyte |
FC | |
● Number, max. | 2 048; Number range: 0 to 7999 |
● Size, max. | 64 kbyte |
OB | |
● Number, max. | see instruction list |
● Size, max. | 64 kbyte |
● Number of free cycle OBs | 1; OB 1 |
● Number of time alarm OBs | 1; OB 10 |
● Number of delay alarm OBs | 2; OB 20, 21 |
● Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 |
● Number of process alarm OBs | 1; OB 40 |
● Number of DPV1 alarm OBs | 3; OB 55, 56, 57 |
● Number of isochronous mode OBs | 1; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously) |
● Number of technology synchronous alarm OBs | 1; OB 65 |
● Number of startup OBs | 1; OB 100 |
● Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) |
● Number of synchronous error OBs | 2; OB 121, 122 |
Nesting depth | |
● per priority class | 16 |
● additional within an error OB | 4 |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 512 |
Retentivity | |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 511 |
— preset | Z 0 to Z 7 |
Counting range | |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 999 |
IEC counter | |
● present | Yes |
● Type | SFB |
● Number | Unlimited (limited only by RAM capacity) |
S7 times | |
● Number | 512 |
Retentivity | |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 511 |
— preset | No retentivity |
Time range | |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer | |
● present | Yes |
● Type | SFB |
● Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 256 kbyte |
Flag | |
● Size, max. | 4 096 byte |
● Retentivity available | Yes; From MB 0 to MB 4 095 |
● Retentivity preset | MB 0 to MB 15 |
● Number of clock memories | 8; 1 memory byte |
Data blocks | |
● Retentivity adjustable | Yes; via non-retain property on DB |
● Retentivity preset | Yes |
Local data | |
● per priority class, max. | 32 768 byte; Max. 2048 bytes per block |
Address area | |
I/O address area | |
● Inputs | 8 192 byte |
● Outputs | 8 192 byte |
of which distributed | |
— Inputs | 8 192 byte |
— Outputs | 8 192 byte |
Process image | |
● Inputs | 8 192 byte |
● Outputs | 8 192 byte |
● Inputs, adjustable | 8 192 byte |
● Outputs, adjustable | 8 192 byte |
● Inputs, default | 1 024 byte |
● Outputs, default | 1 024 byte |
Default addresses of the integrated channels | |
— Digital inputs | 66 |
— Digital outputs | 66 |
Subprocess images | |
● Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes |
Digital channels | |
● Inputs | 65 536 |
— of which central | 256 |
● Outputs | 65 536 |
— of which central | 256 |
Analog channels | |
● Inputs | 4 096 |
— of which central | 64 |
● Outputs | 4 096 |
— of which central | 64 |
Hardware configuration | |
Number of expansion units, max. | 0 |
Number of DP masters | |
● integrated | 2; 1 DP and 1 DP (drive) |
● via CP | 2; for DP |
Number of operable FMs and CPs (recommended) | |
● FM | 8 |
● CP, PtP | 8 |
● CP, LAN | 8 |
Rack | |
● Racks, max. | 1 |
● Modules per rack, max. | 8 |
Time of day | |
Clock | |
● Hardware clock (real-time) | Yes |
● retentive and synchronizable | Yes |
● Backup time | 6 wk; At 40 °C ambient temperature |
● Deviation per day, max. | 10 s; Typ.: 2 s |
● Behavior of the clock following POWER-ON | Clock continues running after POWER OFF |
● Behavior of the clock following expiry of backup period | the clock continues at the time of day it had when power was switched off |
Operating hours counter | |
● Number | 4 |
● Number/Number range | 0 to 3 |
● Range of values | 0 to 2^31 hours (when using SFC 101) |
● Granularity | 1 h |
● retentive | Yes; Must be restarted at each restart |
Clock synchronization | |
● supported | Yes |
● to MPI, master | Yes |
● to MPI, slave | Yes |
● to DP, master | Yes |
● to DP, slave | Yes; Only time-of-day slave |
● in AS, master | Yes |
● in AS, slave | Yes |
● on Ethernet via NTP | Yes; As client |
Digital inputs | |
Number of digital inputs | 4 |
● of which inputs usable for technological functions | 4 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
Number of simultaneously controllable inputs | |
horizontal installation | |
— up to 40 °C, max. | 4 |
— up to 60 °C, max. | 4 |
vertical installation | |
— up to 40 °C, max. | 4 |
Input voltage | |
● Rated value (DC) | 24 V |
● for signal “0” | -3 to +5V |
● for signal “1” | +15 to +30 V |
Input current | |
● for signal “1”, typ. | 7 mA |
Input delay (for rated value of input voltage) | |
for technological functions | |
— at “0” to “1”, max. | 10 µs; Typical |
— at “1” to “0”, max. | 10 µs; Typical |
Cable length | |
● shielded, max. | 1 000 m |
Digital outputs | |
Number of digital outputs | 8 |
● of which high-speed outputs | 8 |
Functions | for technology functions, e.g. high-speed cam switch signals |
Short-circuit protection | Yes |
● Response threshold, typ. | 1 A |
Limitation of inductive shutdown voltage to | 48 V |
Controlling a digital input | No |
Switching capacity of the outputs | |
● on lamp load, max. | 5 W |
Load resistance range | |
● lower limit | 48 Ω |
● upper limit | 4 kΩ |
Output voltage | |
● for signal “0”, max. | 3 V; (2L+) |
● for signal “1”, min. | Rated voltage -2.5 V |
Output current | |
● for signal “1” rated value | 0.5 A |
● for signal “1” permissible range for 0 to 60 °C, min. | 5 mA |
● for signal “1” permissible range for 0 to 60 °C, max. | 0.6 A |
● for signal “0” residual current, max. | 0.3 mA |
Parallel switching of two outputs | |
● for uprating | No |
● for redundant control of a load | No |
Switching frequency | |
● with resistive load, max. | 100 Hz |
● with inductive load, max. | 0.2 Hz; According to IEC 60947-5-1, DC-13 |
● on lamp load, max. | 100 Hz |
Total current of the outputs (per group) | |
horizontal installation | |
— up to 40 °C, max. | 4 A |
— up to 60 °C, max. | 3 A |
all other mounting positions | |
— up to 40 °C, max. | 4 A |
Integrated high-speed cams | |
● Switching accuracy (+/-) | 70 µs |
Cable length | |
● shielded, max. | 1 000 m |
Analog inputs | |
Number of analog inputs | 0 |
Analog outputs | |
Number of analog outputs | 0 |
Encoder | |
Connectable encoders | |
● 2-wire sensor | No |
Interfaces | |
Number of industrial Ethernet interfaces | 1 |
Number of PROFINET interfaces | 1 |
Number of RS 485 interfaces | 2 |
Number of RS 422 interfaces | 0 |
1. Interface | |
Interface type | Integrated RS 485 interface |
Isolated | Yes |
Interface types | |
● RS 485 | Yes |
● Output current of the interface, max. | 200 mA |
Protocols | |
● MPI | Yes |
● PROFIBUS DP master | Yes |
● PROFIBUS DP slave | Yes |
● Point-to-point connection | No |
MPI | |
● Transmission rate, max. | 12 Mbit/s |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | Yes |
— S7 basic communication | Yes |
— S7 communication | Yes |
— S7 communication, as client | No; but via CP and loadable FB |
— S7 communication, as server | Yes |
PROFIBUS DP master | |
● Transmission rate, max. | 12 Mbit/s |
● Number of DP slaves, max. | 124 |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | Yes; I blocks only |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes |
— Equidistance | Yes |
— Isochronous mode | Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO |
— SYNC/FREEZE | Yes |
— Activation/deactivation of DP slaves | Yes |
— Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 |
— Direct data exchange (slave-to-slave communication) | Yes; as subscriber |
— DPV1 | Yes |
Address area | |
— Inputs, max. | 8 kbyte |
— Outputs, max. | 8 kbyte |
User data per DP slave | |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
PROFIBUS DP slave | |
● Transmission rate, max. | 12 Mbit/s |
● automatic baud rate search | Yes; only with passive interface |
● Address area, max. | 32 |
● User data per address area, max. | 32 byte |
Services | |
— PG/OP communication | Yes |
— Routing | Yes; Only with active interface |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes; Connection configured on one side only |
— Direct data exchange (slave-to-slave communication) | Yes |
— DPV1 | No |
Transfer memory | |
— Inputs | 244 byte |
— Outputs | 244 byte |
2. Interface | |
Interface type | Integrated RS 485 interface |
Isolated | Yes |
Interface types | |
● RS 485 | Yes |
● Output current of the interface, max. | 200 mA |
Protocols | |
● MPI | No |
● PROFIBUS DP master | Yes; DP(DRIVE)-Master |
● PROFIBUS DP slave | No |
● Point-to-point connection | No |
PROFIBUS DP master | |
● Transmission rate, max. | 12 Mbit/s |
● Number of DP slaves, max. | 64 |
Services | |
— PG/OP communication | No |
— Routing | No |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | No |
— Equidistance | Yes |
— Isochronous mode | Yes |
— SYNC/FREEZE | No |
— Activation/deactivation of DP slaves | Yes |
— DPV1 | No |
Address area | |
— Inputs, max. | 1 024 byte |
— Outputs, max. | 1 024 byte |
User data per DP slave | |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
PROFIBUS DP slave | |
● GSD file | http://support.automation.siemens.com in Product Support area |
● Transmission rate, max. | 12 Mbit/s |
3. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes; 10/100 Mbit/s |
Autonegotiation | Yes |
Autocrossing | Yes |
Change of IP address at runtime, supported | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
● Number of ports | 2 |
● integrated switch | Yes |
Protocols | |
● MPI | No |
● PROFINET IO Controller | Yes; Also simultaneously with IO-Device functionality |
● PROFINET IO Device | Yes; Also simultaneously with IO Controller functionality |
● PROFIBUS DP master | No |
● PROFIBUS DP slave | No |
● Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP |
● Web server | Yes |
● Media redundancy | Yes |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
— Isochronous mode | Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO |
— Shared device | Yes |
— Prioritized startup | Yes |
— Number of IO devices with prioritized startup, max. | 32 |
— Number of connectable IO Devices, max. | 128 |
— Of which IO devices with IRT, max. | 64 |
— of which in line, max. | 64 |
— Number of connectable IO Devices for RT, max. | 128 |
— of which in line, max. | 128 |
— Activation/deactivation of IO Devices | Yes |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
— IO Devices changing during operation (partner ports), supported | Yes |
— Number of IO Devices per tool, max. | 8 |
— Device replacement without swap medium | Yes |
— Send cycles | 250 µs, 500 µs, 1 ms, 2 ms, 4 ms |
— Updating time | 250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, technical Data” for more details) |
Address area | |
— Inputs, max. | 8 kbyte |
— Outputs, max. | 8 kbyte |
— User data consistency, max. | 1 024 byte |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
— Isochronous mode | No |
— IRT | Yes |
— PROFIenergy | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 2 |
Transfer memory | |
— Inputs, max. | 1 440 byte; Per IO Controller with shared device |
— Outputs, max. | 1 440 byte; Per IO Controller with shared device |
Submodules | |
— Number, max. | 64 |
— User data per submodule, max. | 1 024 byte |
Open IE communication | |
● Number of connections, max. | 16 |
● Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
● Keep-alive function, supported | Yes |
Protocols | |
PROFIsafe | Yes |
Redundancy mode | |
Media redundancy | |
— Switchover time on line break, typ. | 200 ms; PROFINET MRP |
— Number of stations in the ring, max. | 50 |
Open IE communication | |
● TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. | 16 |
— Data length for connection type 01H, max. | 1 460 byte |
— Data length for connection type 11H, max. | 32 768 byte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. | 16 |
— Data length, max. | 32 768 byte |
● UDP | Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. | 16 |
— Data length, max. | 1 472 byte |
Web server | |
● supported | Yes |
● User-defined websites | Yes |
● Number of HTTP clients | 5 |
communication functions / header | |
PG/OP communication | Yes |
Data record routing | Yes |
Global data communication | |
● supported | Yes |
● Number of GD loops, max. | 8 |
● Number of GD packets, max. | 8 |
● Number of GD packets, transmitter, max. | 8 |
● Number of GD packets, receiver, max. | 8 |
● Size of GD packets, max. | 22 byte |
● Size of GD packet (of which consistent), max. | 22 byte |
S7 basic communication | |
● supported | Yes |
● User data per job, max. | 76 byte |
● User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication | |
● supported | Yes |
● as server | Yes |
● as client | Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB |
● User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
S5 compatible communication | |
● supported | Yes; via CP and loadable FC |
Number of connections | |
● overall | 32 |
● usable for PG communication | 31 |
— reserved for PG communication | 1 |
— adjustable for PG communication, min. | 1 |
— adjustable for PG communication, max. | 31 |
● usable for OP communication | 31 |
— reserved for OP communication | 1 |
— adjustable for OP communication, min. | 1 |
— adjustable for OP communication, max. | 31 |
● usable for S7 basic communication | 30 |
— reserved for S7 basic communication | 0 |
— adjustable for S7 basic communication, min. | 0 |
— adjustable for S7 basic communication, max. | 30 |
● usable for S7 communication | 16 |
— reserved for S7 communication | 0 |
— adjustable for S7 communication, min. | 0 |
— adjustable for S7 communication, max. | 16 |
● total number of instances, max. | 32 |
● usable for routing | X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. |
S7 message functions | |
Number of login stations for message functions, max. | 32; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes |
simultaneously active Alarm-S blocks, max. | 300 |
Test commissioning functions | |
Status block | Yes; Up to 2 simultaneously |
Single step | Yes |
Number of breakpoints | 4; without continuation |
Status/control | |
● Status/control variable | Yes |
● Variables | Inputs, outputs, memory bits, DB, times, counters |
● Number of variables, max. | 30 |
— of which status variables, max. | 30 |
— of which control variables, max. | 14 |
Forcing | |
● Forcing | Yes |
● Forcing, variables | Inputs, outputs |
● Number of variables, max. | 10 |
Diagnostic buffer | |
● present | Yes |
● Number of entries, max. | 500 |
— adjustable | No |
— of which powerfail-proof | 100; Only the last 100 entries are retained |
● Number of entries readable in RUN, max. | 499 |
— adjustable | Yes; From 10 to 499 |
— preset | 10 |
Service data | |
● can be read out | Yes |
Interrupts/diagnostics/status information | |
Alarms | No |
Diagnostics function | No |
Diagnostics indication LED | |
● Status indicator digital input (green) | Yes |
● Status indicator digital output (green) | Yes |
Potential separation | |
Potential separation digital inputs | |
● between the channels and backplane bus | Yes |
Potential separation digital outputs | |
● between the channels and backplane bus | Yes |
Isolation | |
Isolation tested with | 500 V DC |
Ambient conditions | |
Ambient temperature during operation | |
● min. | 0 °C |
● max. | 60 °C |
configuration / header | |
Configuration software | |
● STEP 7 | Yes; STEP 7 V5.5 SP2 or higher and S7-Technology Option Package V4.2 SP3, S7 F Configuration Pack V5.5 SP10, S7 Distributed Safety Option Package V5.4 SP5 |
configuration / programming / header | |
● Command set | see instruction list |
● Nesting levels | 8 |
● System functions (SFC) | see instruction list |
● System function blocks (SFB) | see instruction list |
Programming language | |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
— HiGraph® | Yes |
Know-how protection | |
● User program protection/password protection | Yes |
● Block encryption | Yes; With S7 block Privacy |
Dimensions | |
Width | 120 mm |
Height | 125 mm |
Depth | 130 mm |
Weights | |
Weight, approx. | 640 g |
Weight | 0.729 kg |
---|---|
Dimensions | 13.2 × 15.2 × 13.1 cm |