SIMATIC ET 200SP – SIPLUS Extreme RAIL Interface Modules – Siemens

$ 193.82$ 199.98

SKU: N/A
SIPLUS ET 200SP IM 155-6PN ST (BA) TX RAIL

The SIPLUS ET 200SP IM 155-6PN ST (BA) TX RAIL is designed mainly for standard PROFINET applications with average station expansion of up to 32 modules (max. 512 IO signals). All I/O modules, including PROFIsafe, can be used. In addition, the station can be expanded with as many as 16 IP67 modules of the SIMATIC ET 200AL series using BA-Send/BU-Send.

SIPLUS ET 200SP IM 155-6PN HF T1/TX RAIL

The SIPLUS ET 200SP IM 155-6PN HF T1 RAIL/ET 200SP IM 155-6PN HF TX RAIL are designed mainly for PROFINET applications with a high, flexible demand for functions, as well as large station expansion of up to 64 modules (max. 1024 IO signals). All I/O modules, including PROFIsafe, can be used. In addition, the station can be expanded with as many as 16 IP67 modules of the SIMATIC ET 200AL series using BA-Send/BU-Send.

Siemens Modules ET-200SP Product Specifications:

Article number 6AG2155-6AA01-4BN0 6AG2155-6AU01-4BN0 6AG2155-6AU01-1CN0 6AG2155-6AU01-4CN0
SIPLUS ET 200SP IM155-6PN ST BA TX RAIL SIPLUS ET 200SP IM155-6PN ST TX RAIL SIPLUS ET 200SP IM155-6PN HF T1 RAIL SIPLUS ET 200SP IM155-6PN HF TX RAIL
General information
Product type designation IM 155-6 PN ST IM 155-6 PN ST IM 155-6 PN/2 HF IM 155-6 PN/2 HF
Firmware version
● FW update possible Yes Yes
Product function
● I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3
● Module swapping during operation (hot swapping) Yes; Single hot swapping Yes; Single hot swapping Yes; Multi-hot swapping Yes; Multi-hot swapping
● Isochronous mode No No Yes Yes
● Tool changer Yes; Docking station and docking unit Yes; Docking station and docking unit
● Local coupling, IO data No No
● Local coupling, data records No No
Engineering with
● STEP 7 TIA Portal configurable/integrated from version see entry ID: 109746275 see entry ID: 109746275 see entry ID: 109746275 see entry ID: 109746275
Configuration control
via dataset Yes Yes Yes Yes
Supply voltage
Rated value (DC) 24 V 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V
Reverse polarity protection Yes Yes Yes Yes
Short-circuit protection Yes Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms 10 ms 10 ms 10 ms
Input current
Current consumption (rated value) 450 mA 450 mA
Current consumption, max. 550 mA 550 mA 700 mA 700 mA
Inrush current, max. 3.7 A 3.7 A 4.5 A 4.5 A
I²t 0.09 A²·s 0.09 A²·s 0.25 A²·s 0.25 A²·s
Power
Infeed power to the backplane bus 4.5 W 4.5 W
Power loss
Power loss, typ. 1.9 W 1.9 W 2.4 W 2.4 W
Address area
Address space per module
● Address space per module, max. 256 byte; per input / output 256 byte; per input / output 288 byte; For input and output data respectively 288 byte; For input and output data respectively
Address space per station
● Address space per station, max. 512 byte; Dependent on configuration 512 byte; Dependent on configuration 1 440 byte; Dependent on configuration 1 440 byte; Dependent on configuration
Hardware configuration
Rack
● Modules per rack, max. 32; + 16 ET 200AL modules 32; + 16 ET 200AL modules 64; + 16 ET 200AL modules 64; + 16 ET 200AL modules
Submodules
● Number of submodules per station, max. 256 256 256 256
Time stamping
Accuracy 10 ms 10 ms
Interfaces
Number of PROFINET interfaces 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch)
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; Pre-assembled BusAdapter BA 2x RJ45
● Number of ports 2 2 2; via BusAdapter 2; via BusAdapter
● integrated switch Yes Yes Yes Yes
● BusAdapter (PROFINET) Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC
Protocols
● PROFINET IO Device Yes Yes Yes Yes
● Open IE communication Yes Yes Yes Yes
● Media redundancy Yes; PROFINET MRP Yes; PROFINET MRP Yes; PROFINET MRP Yes; PROFINET MRP
Interface types
RJ 45 (Ethernet)
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX) PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 10 Mbps Yes; for Ethernet services Yes; for Ethernet services No No
● 100 Mbps Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● Autonegotiation Yes Yes Yes Yes
● Autocrossing Yes Yes Yes Yes
Protocols
Number of connections
● Number of MtM communication relationships/connections, max. 16 16
PROFINET IO Device
Services
— IRT Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame
— PROFIenergy Yes Yes Yes Yes
— Prioritized startup Yes Yes Yes Yes
— Shared device Yes Yes Yes Yes
— Number of IO Controllers with shared device, max. 2 2 4 4
Redundancy mode
● PROFINET system redundancy (S2) No No Yes; NAP S2 Yes; NAP S2
● Redundant PROFINET configuration (R1) No No
● H-Sync forwarding Yes Yes
Media redundancy
— MRP Yes Yes Yes Yes
— MRPD No No No No
Open IE communication
● TCP/IP Yes Yes Yes Yes
● SNMP Yes Yes Yes Yes
● LLDP Yes Yes Yes Yes
Isochronous mode
Equidistance Yes Yes
shortest clock pulse 250 µs 250 µs
max. cycle 4 ms 4 ms
Bus cycle time (TDP), min. 250 µs 250 µs
Jitter, max. 1 µs 1 µs
Interrupts/diagnostics/status information
Status indicator Yes Yes Yes Yes
Alarms Yes Yes Yes Yes
Diagnostics function Yes Yes Yes Yes
Diagnostics indication LED
● RUN LED Yes; green LED Yes; green LED Yes; green LED Yes; green LED
● ERROR LED Yes; red LED Yes; red LED Yes; red LED Yes; red LED
● MAINT LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED Yes; Yellow LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED
● Connection display LINK TX/RX Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter Yes; 2x green link LEDs on BusAdapter
Potential separation
between backplane bus and electronics No No No No
between PROFINET and all other circuits Yes; 1 500 V AC Yes; 1 500 V AC Yes Yes
between supply and all other circuits No No No No
Permissible potential difference
between different circuits Safety extra low voltage SELV Safety extra low voltage SELV
Isolation
Isolation tested with 750 V DC (type test) and according to EN 50155 (routine test) 750 V DC (type test) and according to EN 50155 (routine test) 750 V DC (type test) and according to EN 50155 (routine test) 750 V DC (type test) and according to EN 50155 (routine test)
Standards, approvals, certificates
Network loading class 2 2 3 3
Security level According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1 According to Security Level 1 Test Cases V1.1.1
Railway application
● EN 50121-3-2 Yes; EMC for rail vehicles Yes; EMC for rail vehicles Yes; EMC for rail vehicles Yes; EMC for rail vehicles
● EN 50121-4 Yes; EMC for signal and telecommunications systems Yes; EMC for signal and telecommunications systems Yes; EMC for signal and telecommunications systems Yes; EMC for signal and telecommunications systems
● EN 50124-1 Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC Yes; Railway applications – overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
● EN 50125-1 Yes; Rail vehicles – see ambient conditions Yes; Rail vehicles – see ambient conditions Yes; Rail vehicles – see ambient conditions Yes; Rail vehicles – see ambient conditions
● EN 50125-2 Yes; Stationary electrical equipment – see ambient conditions Yes; Stationary electrical equipment – see ambient conditions Yes; Stationary electrical equipment – see ambient conditions Yes; Stationary electrical equipment – see ambient conditions
● EN 50125-3 Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) Yes; Signal and telecommunications systems – see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
● EN 50155 Yes; Rail vehicles – temperature class OT4, ST1/ST2, horizontal mounting position Yes; Rail vehicles – temperature class OT4, ST1/ST2, horizontal mounting position Yes; Rail vehicles – temperature class OT1, ST1/ST2, horizontal mounting position Yes; Rail vehicles – temperature class OT4, ST1/ST2, horizontal mounting position
● EN 61373 Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B Yes; Rail vehicles – vibrations and shocks: Category 1 Class A/B
● Fire protection acc. to EN 45545-2 Yes; For proof of conformity, see Service & Support Yes; For proof of conformity, see Service & Support Yes; For proof of conformity, see Service & Support Yes; For proof of conformity, see Service & Support
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost) -30 °C; = Tmin (incl. condensation/frost) -40 °C; = Tmin (incl. condensation/frost)
● horizontal installation, max. 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) 60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155) 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155)
● vertical installation, min. -40 °C; = Tmin -40 °C; = Tmin -30 °C; = Tmin -40 °C; = Tmin
● vertical installation, max. 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax 50 °C; = Tmax
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 2 000 m 2 000 m 2 000 m 2 000 m
● Ambient air temperature-barometric pressure-altitude Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m) Tmin … Tmax at 1 140 hPa … 795 hPa (-1 000 m … +2 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricants Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3 Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, * Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3 Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5 Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
— to chemically active substances according to EN 60721-3-5 Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-5 Yes; Class 5S3 incl. sand, dust; * Yes; Class 5S3 incl. sand, dust; * Yes; Class 5S3 incl. sand, dust; * Yes; Class 5S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-5 Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
— against mechanical environmental conditions in agriculture acc. to ISO 15003 Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4 Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene) Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation! * The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086 Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3 Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection Yes; Type 1 protection
● Electronic equipment on rolling stock acc. to EN 50155 Yes; Class PC2 protective coating acc. to EN 50155:2017 Yes; Class PC2 protective coating acc. to EN 50155:2017 Yes; Class PC2 protective coating acc. to EN 50155:2017 Yes; Class PC2 protective coating acc. to EN 50155:2017
● Military testing according to MIL-I-46058C, Amendment 7 Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A Yes; Conformal coating, Class A
connection method / header
ET-Connection
● via BU/BA Send Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules Yes; + 16 ET 200AL modules
Mechanics/material
Strain relief Yes; Optional Yes; Optional
Dimensions
Width 50 mm 50 mm 50 mm 50 mm
Height 117 mm 117 mm 117 mm 117 mm
Depth 74 mm 74 mm 74 mm 74 mm
Weights
Weight, approx. 190 g; IM 155-6 PN BA with 2x RJ45 ports and server module 147 g; without BusAdapter 120 g; without BusAdapter 120 g; without BusAdapter
Other
Note: for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776 for use in railway applications, also observe the product information “SIPLUS extreme RAIL” A5E37661960A, Online Support article 109736776
Weight N/A
Dimensions N/A

Related products