$ 124.52
The SB 1232 analog output signal board converts digital signals of the S7-1200 controller into analog signals for the process.he signal boards are plugged directly into the receptacle on the front of each S7-1200 CPU.
Article number | 6ES7232-4HA30-0XB0 |
Signal Board SB 1232, 1 AO | |
General information | |
Product type designation | SB 1232, AQ 1×12 bit |
Input current | |
from backplane bus 5 V DC, typ. | 15 mA |
output voltage / header | |
supply voltage of the transmitters / header | |
● supply current / from supply voltage for transmitter / maximum | 25 mA |
Power loss | |
Power loss, typ. | 1.5 W |
Analog inputs | |
Number of analog inputs | 0 |
Analog outputs | |
Number of analog outputs | 1 |
Cycle time (all channels) max. | Voltage: 300 μS (R), 750 μS (1 uF) Current: 600 ms (1 mH); 2 ms (10 mH) |
Output ranges, voltage | |
● -10 V to +10 V | Yes |
Output ranges, current | |
● 0 to 20 mA | Yes |
Load impedance (in rated range of output) | |
● with voltage outputs, min. | 1 000 Ω |
● with current outputs, max. | 600 Ω |
Cable length | |
● shielded, max. | 100 m; shielded, twisted pair |
Analog value generation for the outputs | |
Conversion principle | Differential |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 12 bit |
Errors/accuracies | |
Temperature error (relative to output range), (+/-) | 25 °C ±0.5%, to 55 °C ±1% |
Interrupts/diagnostics/status information | |
Alarms | Yes |
Diagnostics function | Yes |
Diagnostics indication LED | |
● for status of the outputs | Yes |
Standards, approvals, certificates | |
CE mark | Yes |
CSA approval | Yes |
UL approval | Yes |
cULus | Yes |
FM approval | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
Marine approval | Yes |
Ambient conditions | |
Free fall | |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
● min. | -20 °C |
● max. | 60 °C |
● horizontal installation, min. | -20 °C |
● horizontal installation, max. | 60 °C |
● vertical installation, min. | -20 °C |
● vertical installation, max. | 50 °C |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Storage/transport, min. | 660 hPa |
● Storage/transport, max. | 1 080 hPa |
Relative humidity | |
● Operation at 25 ℃ without condensation, max. | 95 % |
Pollutant concentrations | |
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
Mechanics/material | |
Enclosure material (front) | |
● Plastic | Yes |
Dimensions | |
Width | 38 mm |
Height | 62 mm |
Depth | 21 mm |
Weights | |
Weight, approx. | 40 g |
Weight | 0.03 kg |
---|---|
Dimensions | 5 × 8.3 × 2.9 cm |