SICK 1040466 DT500-A511 Analog Distance Sensor

USD 2,823.86

DT500-A511 measures natural targets over 0.2–70 m at 90% remission, with current output, 150–6,000 ms response, M12 and IP65 metal housing.

SKU SICK-1040466 Category
Laser Distance Sensors - SICK Dx500

SICK DT500-A511 Laser Distance Sensor

BrandSICK
Model IdentifierDT500-A511
Official Part Number1040466

Technical Overview

The SICK DT500-A511 measures distance to natural objects using a visible Class 2 red laser and time-of-flight sensing. Its measuring range is 0.2–70 m on 90% remission targets and 0.2–30 m on 6% remission targets, with the specified range applying under no more than 1 klx of constant ambient light. The sensor provides one configurable 0–20 mA or 4–20 mA current output, with 150–6,000 ms response and output time. A seven-segment display and local controls support commissioning, while the IP65 aluminum diecast housing and M12 five-pin connector support installation on a suitable mounting fixture. The sensor operates from −10 to +45 °C, uses a 10–30 V DC supply and consumes typically 3 W.

Time-of-flight sensor for natural targets, 0.2–70 m at 90% remission, with configurable current output, 150–6,000 ms response and an IP65 metal housing.

Key Features

  • 0.2–70 m at 90% remission; 0.2–30 m at 6% remission
  • Natural-object time-of-flight sensing; specified range at ≤1 klx constant ambient light
  • Visible red Class 2 laser; 650 nm wavelength
  • 150–6,000 ms response and output time
  • 1 mm repeatability, 1σ, at 6–90% remission; ±3 mm measurement accuracy
  • One 12-bit current output, configurable 0–20 mA or 4–20 mA
  • Local current-span setup plus external teach-in and laser-off through PNP MF input
  • Seven-segment display with local control panel
  • 10–30 V DC, reverse-polarity protection; typical consumption 3 W
  • IP65 aluminum diecast housing, glass window and M12 five-pin connector

Measure natural target surfaces without a reflector and deliver a scaled current signal to external machine control.

Technical Specification Matrix

ParameterValue
Functional principleTime-of-flight laser distance measurement to natural objects
Measuring range0.2–70 m at 90% remission; 0.2–30 m at 6% remission; maximum 1 klx constant ambient light; unambiguous up to 150 m
Resolution12 bit; analog-output resolution limits accuracy at longer measurement ranges
Repeatability1 mm; statistical error 1σ; 6–90% remission
Measurement accuracy±3 mm
Response time150–6,000 ms
Output time150–6,000 ms
Light sourceVisible red laser
Wavelength650 nm
Laser class2; IEC 60825-1:2014, EN 60825-1:2014
Laser outputMaximum ≤2 mW
Laser modulation frequency700–1,200 MHz
Typical light spot size10 mm at 7 m; 45 mm at 30 m; 100 mm at 70 m; spot figures do not extend the selected measuring range
Laser service lifeAverage 50,000 h at ambient +25 °C
Analog outputOne current output: configurable 0–20 mA or 4–20 mA
Maximum load resistance(Uv − 2 V) / 0.0205 A
Multifunction inputPNP, active HIGH; HIGH=Uv−(<2 V), LOW=<2 V; laser-off input >12 V
External teach-inMF pulse: 60–150 ms exclusive for 0 mA; 150–250 ms exclusive for 4 mA; 250–350 ms exclusive for 20 mA; current measured distance is taught
Laser-off controlMF held for >450 ms
Pin assignment1 BN=L+; 2 WH=QA current signal; 3 BU=M; 4 BK=MQA analog reference; 5 GY=MF
Diagnostic output valuesMeasurement not possible: 0/3.5 mA; no object in measuring range or laser off: 20.5 mA
Power supply10–30 V DC, reverse-polarity protected
Power consumptionTypically 3 W
Residual rippleMaximum 5 Vpp; supply limits must not be exceeded or undershot
Initialization time500 ms
Warm-up timeAt −10 °C: typically 7 min at supply 24 V or 10 min at supply 10 V
Display and adjustmentSeven-segment indicator panel, operating indicator and local control panel
ConnectionMale M12 five-pin connector
MountingFixing holes; compatible BEF-DSDT alignment unit available separately
Housing materialAluminum diecast metal
Window materialGlass
IP ratingIP65
Operating temperature−10 to +45 °C; −10 to +75 °C with separate cooling case
Storage temperature−25 to +75 °C
Temperature driftTypically 0.05 mm/K
Ambient light immunityTypically ≤3,000 lx; specified measuring range separately requires ≤1,000 lx constant ambient light
Mechanical loadShock EN 60068-2-27 / -2-29; sine EN 60068-2-6; noise EN 60068-2-64
EMCEN 61000-6-2 / EN 61000-6-3
MTTFD101 years
DCavg0%
Physical Weight (kg)1

Industrial Applications

1. Following a material surface in a storage vessel

A storage vessel can direct the sensor toward a sufficiently reflecting material surface and derive its level from the measured distance. External process control reads the scaled current signal as the surface rises or falls. The installation keeps the target within its remission-dependent range, and the actual surface return, optical path and ambient-light conditions are validated for the vessel geometry.

Problem Solved

A changing distance to the material surface supplies external control with a non-contact level reference, helping track consumption or filling without inserting a mechanical follower into the material.

Surface level Natural target Distance feedback

2. Tracking a moving carrier along a machine rail

A machine rail can present a sufficiently reflecting face on a moving carrier to the sensor. External motion supervision reads the scaled current signal to track the carrier position within the selected measuring range. Carrier speed and evaluation timing are matched to the specified response and output time, while the visible laser spot assists alignment to the intended target face.

Problem Solved

Distance feedback gives external supervision a position reference along the rail, helping coordinate ordinary transport stages without installing a separate reflector on the moving carrier.

Carrier position Time-of-flight External supervision

3. Evaluating part length against a fixed backstop

A fixture can locate one end of a large part against a fixed backstop and aim the sensor at the opposite reflecting face. External inspection control combines the known fixture reference with the scaled current signal to evaluate length. The target remains within the selected range; part alignment, return strength and measurement accuracy are considered when defining the acceptance tolerance.

Problem Solved

A repeatable fixture reference and measured end-face distance provide an external length estimate, helping separate incorrectly sized parts before the following assembly or handling operation.

Fixture inspection End-face distance Length evaluation