SICK 6037661 UM30-212111 1×PNP Ultrasonic Sensor

USD 364.52

UM30-212111 offers 65–350 mm ultrasonic operation, 1 PNP output, 64 ms response, display adjustment and an IP65/IP67 M30 housing with M12 connection.

SKU SICK-6037661 Category
Ultrasonic Distance Sensors - SICK UM30

SICK UM30-212111 PNP Ultrasonic Sensor

BrandSICK
Model IdentifierUM30-212111
Official Part Number6037661

Technical Overview

The SICK UM30-212111 detects reflecting objects using ultrasonic echoes across a 65–350 mm operating range, with a separate 600 mm limiting range. One PNP digital output reports the configured distance condition. Switching-point, window and background modes, output inversion and adjustable measurement filters adapt detection to the target. The specified response is 64 ms, switching frequency 12 Hz and output time 16 ms. Internal temperature compensation reaches its best working point after approximately 30 minutes. An LED display and local controls support setup; the multifunction input supports synchronization and multiplexing. The straight-sensing M30 threaded housing has an M12 five-pin male connector and IP65/IP67 protection.

65–350 mm ultrasonic sensor with 1 PNP output, 64 ms response, local display, M30 thread and M12 five-pin connection.

Key Features

  • 65–350 mm operating range; 600 mm limiting range
  • One PNP digital output; invertible switching condition
  • 64 ms response; 12 Hz switching; 16 ms output time
  • Switching-point, window and background detection modes
  • Teach-in, output inversion, on delay and adjustable measurement filters
  • Temperature compensation; optimum after approximately 30 minutes
  • Synchronization and multiplexing via MF; up to 50 interconnected sensors
  • LED display and two status LEDs; local controls; factory reset
  • 9–30 V DC; ≤2.4 W without load; startup <300 ms
  • M30 × 1.5 thread; M12 five-pin connector; IP65/IP67 housing

Teach distance conditions locally and deliver ultrasonic switching results to external machine or process control.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic object/distance detection
Operating range65–350 mm
Limiting range600 mm; distinct from operating range
Detection areaDepends on reflection, size and target alignment; validate the actual target and mounting geometry
Resolution≥0.18 mm
Repeatability±0.15% of current measured value; minimum value ≥resolution
Measurement accuracy±1% of current measured value
Temperature compensationAvailable; can be disabled; optimum after approximately 30 min
Uncompensated temperature drift0.17%/K with temperature compensation disabled
Response time64 ms
Switching frequency12 Hz
Output time16 ms
Ultrasonic frequencyTypical 400 kHz; acoustic frequency
Digital output1 × PNP; maximum output current ≤200 mA
Switching modesSwitching point (DtO), window, object between sensor and background (ObSB)
Hysteresis5 mm; configurable using Connect+
AdjustmentLocal teach-in and numeric settings; output inversion, on delay, measurement filters, foreground suppression, sensitivity/detection area; factory reset
Synchronization and multiplexingVia MF pin 5; up to 50 interconnected sensors; multiplexing requires distinct addresses
Multifunction input1 × MF
Multiple-sensor separationWithout synchronization/multiplexing: parallel >40 cm; opposite >250 cm
Power supply9–30 V DC; limit values; reverse-polarity protected
Supply network requirementShort-circuit protected network, maximum 8 A, Class 2
Power consumption≤2.4 W without load
Initialization time<300 ms
Indicators and controlsLED display, 2 status LEDs and T1/T2 controls; display can be deactivated
ConnectionM12 five-pin male connector
Pin assignment1 BN=L+; 3 BU=M/0 V; 4 BK=Q/inverted Q; 2 WH=not connected; 5 GY=Sync/Multi and Connect+ communication
Mounting threadM30 × 1.5
Mounting nuts36 mm across flats; maximum tightening torque 40 Nm
Sending axisStraight
Housing materialsNickel-plated brass and PBT; display TPU
Transducer materialsPolyurethane foam and glass epoxy resin
IP ratingIP65/IP67
Protection classIII
Operating temperature−25 to +70 °C
Storage temperature−40 to +85 °C
MTTFD101 years
DCavg0%
Physical Weight (kg)0.15

Industrial Applications

1. Monitoring material level in a large vessel

A vessel can present a sufficiently reflecting material surface within the 65–350 mm operating range. The sensor is aligned to the surface, and its local controls teach the required distance condition. External level control evaluates the PNP switching result after checking actual material echoes, temperature stabilization and the 64 ms response against the filling cycle.

Problem Solved

A taught surface-distance condition gives external filling control a repeatable process threshold, helping it recognize when the material surface reaches the selected level without contacting the material.

Material level Taught thresholds External filling control

2. Checking the position of a large load face

A handling station can present a reflecting load face within the 65–350 mm operating range and configure an acceptance window using the local display and controls. External sequence control interprets the selected PNP output condition before the next transfer step. Actual target alignment, window boundaries and return strength are validated, and the configured measurement filters are matched to the presentation cycle.

Problem Solved

A distance window provides external handling control with a selected acceptance zone for a large load face, helping it recognize an object placed too near or too far before transfer.

Load face Acceptance window Local settings

3. Coordinating adjacent ultrasonic process stations

Adjacent process stations can connect compatible sensors through MF pin 5 and configure synchronization or addressed multiplexing to manage ultrasonic interference. Each target remains within its sensor operating range, and external control evaluates the configured digital results. Up to 50 sensors can be interconnected, while actual geometry, target returns and timing are validated for the selected coordination mode.

Problem Solved

Coordinated ultrasonic operation helps external process control obtain usable target-distance conditions at adjacent stations where independent transmissions could interfere, supporting a practical sensing arrangement across several detection points.

Sensor coordination MF connection Adjacent stations