SICK 6036921 UM30-211118 Analog/PNP Ultrasonic Sensor

SICK 6036921 UM30-211118 Analog/PNP Ultrasonic Sensor

USD 928.20

UM30-211118 offers 30–250 mm ultrasonic operation, load-selected 4–20 mA or 0–10 V output plus PNP switching, local display and M12 five-pin connection.

SKU: SICK-6036921 Category:
Ultrasonic Distance Sensors - SICK UM30

SICK UM30-211118 Analog/PNP Ultrasonic Sensor

BrandSICK
Model IdentifierUM30-211118
Official Part Number6036921

Technical Overview

The SICK UM30-211118 measures reflecting objects using ultrasonic echoes over a 30–250 mm operating range, with a separate 350 mm limiting range. Its single analog output automatically selects 4–20 mA current or 0–10 V voltage according to the connected load. A separate PNP digital output reports a configured switching condition. Local display controls teach and scale the analog span, including rising or falling characteristics. The specified 32 ms response can increase by up to 200% because of subsequent analog smoothing; output time is 8 ms. Internal temperature compensation reaches its best working point after approximately 30 minutes. The M30 threaded housing has an M12 five-pin connector, MF synchronization/multiplexing input and IP65/IP67 protection. Voltage output requires 15–30 V DC.

30–250 mm ultrasonic sensor with one load-selected 4–20 mA or 0–10 V analog output, separate PNP switching, local display and M12 five-pin connection.

Key Features

  • 30–250 mm operating range; 350 mm limiting range
  • One load-selected 4–20 mA or 0–10 V analog output; 12 bit
  • Current load ≤500 Ω; supply ≤20 V limits current load to ≤100 Ω
  • Voltage load ≥100,000 Ω; voltage mode requires 15–30 V DC
  • One PNP digital output, ≤200 mA; switching-point/window/background modes
  • 32 ms response; analog smoothing may increase it by up to 200%
  • Temperature compensation; optimum after approximately 30 minutes
  • MF synchronization/multiplexing; up to 50 interconnected sensors
  • LED display and two status LEDs; local T1/T2 controls
  • M30 × 1.5 thread; M12 five-pin connector; IP65/IP67 protection

Scale an ultrasonic distance signal locally and send analog feedback to external process or machine control.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic distance measurement
Operating range30–250 mm
Limiting range350 mm; distinct from operating range
Detection areaDepends on reflection, size and target alignment; validate the actual target and mounting geometry
Resolution≥0.18 mm
Repeatability±0.15% of current measured value; minimum value ≥resolution
Measurement accuracy±1% of current measured value
Temperature compensationAvailable; can be disabled; optimum after approximately 30 min
Uncompensated temperature drift0.17%/K with temperature compensation disabled
Response time32 ms; subsequent analog smoothing may increase response time by up to 200%
Output time8 ms
Ultrasonic frequencyTypical 320 kHz; acoustic frequency
Analog output1 × current/voltage output; automatic 4–20 mA or 0–10 V selection according to connected load
Analog load requirements4–20 mA: ≤500 Ω, reduced to ≤100 Ω at supply ≤20 V; 0–10 V: ≥100,000 Ω
Analog output resolution12 bit
AdjustmentLocal teach-in and numeric analog scaling; rising/falling output characteristic; measurement filters, foreground suppression, sensitivity/detection area; display deactivation and factory reset
Synchronization and multiplexingVia MF pin 5; up to 50 interconnected sensors; multiplexing requires distinct addresses
Multifunction input1 × MF
Multiple-sensor separationWithout synchronization/multiplexing: parallel >35 cm; opposite >250 cm
Power supply9–30 V DC; 15–30 V DC required for analog voltage output; limit values; reverse-polarity protected
Supply network requirementShort-circuit protected network, maximum 8 A, Class 2
Power consumption≤2.4 W without load
Initialization time<300 ms
Indicators and controlsLED display, 2 status LEDs, local T1/T2 controls; green analog LED indicates object within scaling range
ConnectionM12 five-pin male connector
Pin assignment1 BN=L+; 3 BU=M/0 V; 2 WH=QA analog output; 5 GY=Sync/Multi and Connect+ communication; 4 BK=Q/inverted Q digital output
Mounting threadM30 × 1.5
Mounting nuts36 mm across flats; maximum tightening torque 40 Nm
Sending axisStraight
Housing materialsNickel-plated brass and PBT; display TPU
Transducer materialsPolyurethane foam and glass epoxy resin
IP ratingIP65/IP67
Protection classIII
Operating temperature−25 to +70 °C
Storage temperature−40 to +85 °C
MTTFD101 years
DCavg0%
Physical Weight (kg)0.15
Digital output1 × PNP; maximum output current ≤200 mA
Switching frequency25 Hz
Hysteresis3 mm; configurable using Connect+
Switching modesSwitching point (DtO), window, object between sensor and background (ObSB); output inversion and on delay

Industrial Applications

1. Following material level in a vessel

A vessel can present a sufficiently reflecting material surface inside the 30–250 mm operating range. Local controls teach analog scaling endpoints, and external filling control receives the load-selected current or voltage signal. The receiver load and supply voltage are matched to the selected analog mode, while actual surface returns, temperature stabilization and the filtered response are validated for the filling cycle. The separate PNP output can provide a configured distance threshold to that external control.

Problem Solved

A scaled surface-distance signal lets external filling control follow material level continuously and compare it with process limits, helping it recognize a changing fill condition without contacting the surface.

Material level Scaled distance Receiver matching

2. Tracking a web loop for feed control

A web handling station can align the sensor toward a sufficiently reflecting material loop and keep the target inside the 30–250 mm operating range. External feed control evaluates the analog distance signal to track loop movement. The taught scaling direction, connected receiver load and actual material echo are checked, and any analog smoothing is included when matching feedback timing to the process.

Problem Solved

Changing loop-distance feedback gives external feed control a position reference that it can compare with its chosen process limits, helping recognize drift toward a near or far loop boundary.

Web loop Feedback timing External feed control

3. Estimating material build-up on a roll

A winding station can mount the sensor toward the outer roll surface and keep that reflecting surface within the 30–250 mm operating range. The local display supports teaching a useful analog span, and external winding control receives the scaled signal. A process estimate of roll build-up uses the independently known roll axis and sensor mounting geometry, with actual surface alignment and returns checked during commissioning.

Problem Solved

An analog surface-distance reference helps external winding control follow changing roll geometry and estimate material build-up when its mounting position and roll axis are known independently of the sensor.

Roll surface External geometry Analog scaling