DL50-P2225 Mid Range Distance Sensors – SICK Sensor

$ 1,435.72

SKU: SICK 1048418

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1048418
Distance Sensor Model: DL50-P2225
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 10 V … 30 V 1)
Ripple ≤ 5 Vpp 2)
Power consumption ≤ 2.1 W 3)
Initialization time ≤ 250 ms
Warm-up time ≤ 15 min
Housing material Metal (zinc diecast)
Window material Plastic (PMMA)
Connection type Male connector, M12, 8-pin
Indication LC display, 2 x LED
Weight 200 g
Dimensions (W x H x D) 36.1 mm x 62.7 mm x 57.7 mm
Enclosure rating IP65
Protection class III
  • 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
  • 2) May not fall short of or exceed VS tolerances.
  • 3) Without load.

Performance

Measuring range 200 mm … 50,000 mm, on “diamond grade” reflective tape 1)
Target Reflector
Resolution 0.1 mm
Repeatability ≥ 0.25 mm 2) 3) 4)
Accuracy ± 3 mm 5)
Response time 10 ms … 160 ms, 10 ms / 40 ms / 160 ms 3) 6)
Output time 2.5 ms 7) 8)
Light source Laser, red
visible red light
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) 9)
Typ. light spot size (distance) 15 mm x 15 mm (10 m)
Additional function Set moving average fast/medium/slow, switching mode: distance to object (DtO), teach-in, scaling and inversion of digital output, set hysteresis, Multifunctional input and output: Laser off, external teach, digital output 2, deactivated, Adjustable resolution of the SSI distance output: 0.0625 mm / 0.1 mm / 0.125 mm / 1 mm, Unique measurement value, crosstalk safety, switch-off display, reset to factory default, lock user interface
Average laser service life (at 25 °C) 100,000 h
  • 1) On “diamond grade” reflective tape.
  • 2) Equivalent to 1 σ.
  • 3) Dependent on the averaging setting: fast/medium/slow.
  • 4) Typical value.
  • 5) 200 mm … 4,000 mm: ≤ ± 5 mm.
  • 6) Lateral entry of the object into the measuring range.
  • 7) For baud rate 115,200 bps.
  • 8) Continuous change of distance in measuring range.
  • 9) Wavelength: 658 nm; max. output: 80 mW; pulse duration: 2.5 ns; duty cycle: 1/240.

Interfaces

Serial ✔ , RS-422
Digital output
Number 1 … 2 1) 2)
Type PNP
Function Dependent on the set function MF: digital output 2 / laser off, external teach
Maximum output current IA ≤ 100 mA
Multifunctional input (MF) − / 1 x 3) 4) 5)
Hysteresis 1 mm … 1,000 mm
  • 1) Output Q short-circuit protected.
  • 2) PNP: HIGH = VS – (< 2.5 V) / LOW = 0 V.
  • 3) Dependent on the set function MF: digital output 2 / laser off, external teach.
  • 4) Response time ≤ 60 ms.
  • 5) PNP: HIGH = V/ LOW = ≤ 2.5 V.

Ambient data

Ambient temperature, operation –30 °C … +65 °C

–30 °C … +80 °C, operation with 2 cooling plates

–30 °C … +140 °C, operation with 2 cooling plates and protection filter

Ambient temperature, storage –40 °C … +75 °C
Max. rel. humidity (not condensing) ≤ 95 %
Typ. Ambient light immunity 40,000 lx
Vibration resistance EN 60068-2-6, EN 60068-2-64
Shock resistance EN 60068-2-27