SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6053548
Distance Sensor Model: UM12-1192261
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 10 V … 30 V 1)
Power consumption ≤ 1.2 W 2)
Initialization time < 300 ms
Design Cylindrical
Housing material Metal (nickel-plated brass, PBT)

Ultrasonic transducer: polyurethane foam, glass epoxy resin

Thread size M12 x 1
Connection type Male connector, M12, 4-pin
Indication 2 x LED
Weight 15 g
Sending axis Straight
Dimensions (W x H x D) 12 mm x 12 mm x 60.1 mm
Enclosure rating IP65 / IP67
Protection class III
  • 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
  • 2) Without load.

Performance

Operating range, limiting range 40 mm … 240 mm, 350 mm
Target Natural objects
Resolution ≥ 0.069 mm
Repeatability ± 0.15 % 1)
Accuracy ± 1 % 2)
Temperature compensation
Response time 30 ms 3)
Output time 10 ms
Ultrasonic frequency (typical) 500 kHz
Additional function Teach-in of analog output, Invertable analog output, reset to factory default
4)
  • 1) In relation to the current measured value, minimum value ≥ resolution.
  • 2) Referring to current measurement value.
  • 3) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
  • 4) Functions may vary depending on sensor type.

Interfaces

Analog output
Number 1
Type Current output
Current 4 mA … 20 mA, ≤ 500 Ω 1)
Resolution 12 bit
  • 1) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.

Ambient data

Ambient temperature, operation –25 °C … +70 °C
Ambient temperature, storage –40 °C … +85 °C