$ 5,129.54
Optimize industrial precision with the SICK OD5-30T05 (6035977) laser displacement sensor. Features 0.2 µm repeatability, 10 kHz frequency, and IP67 metal housing.
The SICK OD Precision (Part No. 6035977, Model OD5-30T05) is a high-performance laser triangulation sensor designed for extreme accuracy in demanding industrial environments. Featuring a precise measuring range of 25 mm to 35 mm, this sensor head delivers a remarkable repeatability of 0.2 µm and linearity of ± 4 µm for specular surfaces. Its advanced CMOS receiving element enables reliable measurement regardless of surface color or gloss, making it ideal for monitoring difficult materials like glass, semi-transparent objects, or polished metals.
A key advantage of the OD Precision system is its flexibility; the OD5-30T05 can function as a standalone unit via its integrated RS-422 interface or be paired with the AOD5 evaluation unit. When connected to the controller, users can integrate up to three sensors to perform complex tasks like thickness measurement or surface evenness calculations with minimal hardware. The sensor’s robust IP67 metal housing and high measuring frequency of up to 10 kHz ensure high-speed, precise data acquisition even in harsh conditions. Whether used for semiconductor manufacturing or quality control in automotive production, this sensor provides the sub-micron precision required for modern automated systems.
| System part | Sensor head |
| Supply voltage Vs | DC 12 V … 24 V 1) |
| Warm-up time | ≤ 5 min |
| Housing material | Metal (Aluminum) |
| Window material | Glass |
| Connection type | 0.5 m cable with connector 2) |
| Indication | LEDs, 4” color display on optional evaluation unit |
| Weight | 250 g 3) |
| Dimensions (W x H x D) | 29 mm x 78 mm x 75 mm |
| Enclosure rating | IP67 |
| Protection class | III |
| Measuring range | 25 mm … 35 mm 1) 2) |
| Target | Natural objects |
| Repeatability | 0.2 µm 3) |
| Linearity | Diffuse ± 8 µm 3)
Specular ± 4 µm 3) |
| Response time | ≥ 0.1 ms 4) 5) |
| Measuring frequency | ≤ 10 kHz 1) 5) |
| Output time | ≥ 0.1 ms |
| Light source | Laser, red visible red light |
| Laser class | 2 (IEC 60825-1:2014, EN 60825-1:2014) 6) |
| Typ. light spot size (distance) | 30 µm x 100 µm (30 mm) |
| Special task | Thickness measurement of transparent material |
| Additional function | Mean-value setting 1 … 4,096x, selectable measuring frequency (automatic / 0.1 ms … 3.2 ms), automatic sensitivity adjustment, manual sensitivity adjustment, Mutual interference, Glass thickness measurement |
| Thickness measurement of transparent material | 0.7 mm … 5 mm |
|
|||||||||||
|
|||||||||||
|
|||||||||||
| Laser-off input | 1 x laser-off | ||||||||||
| Ambient temperature, operation | –10 °C … +50 °C |
| Ambient temperature, storage | –20 °C … +60 °C |
| Relative air humidity (non-condensing) | 35 % … 85 % |
| Temperature drift | ± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor) |
| Typ. Ambient light immunity | Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx |
| Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
| Shock resistance | 50 G (x, y, z axis 3 times each) |