1. Counting separated components through a fiber beam
A feeder can use a compatible through-beam fiber arrangement across the component path, with the base amplifier evaluating the returned optical signal. Each separated opaque component interrupts the beam and changes the PNP output state. The selected response setting establishes transition timing, while the digital display shows the received value and switching threshold. The two outputs are individually adjustable.
Problem Solved
Fiber-guided sensing brings the detection point into a constrained component path, producing count events while the amplifier remains accessible for threshold adjustment and signal review.
Fiber-dependent optics
PNP
Selectable response
2. Checking a part in a confined assembly fixture
An assembly fixture can position a compatible reflective fiber head near the expected part location while mounting the amplifier in an accessible machine area. The fiber determines the optical sensing arrangement, and the amplifier display and operating buttons establish the switching threshold. The PNP output reports the resulting part-presence state to the controller. The two outputs are individually adjustable.
Problem Solved
Separating the optical head from the amplifier allows a local presence check in a confined fixture while keeping the adjustment controls and received-signal display accessible.
Remote fiber head
Digital display
Part presence
3. Bridging short gaps in sheet feed
A sheet feeder can use a compatible fiber arrangement to monitor material in a narrow feed path. The amplifier evaluates the light-state changes and applies a programmed off delay so brief gaps do not immediately release the output. A longer absence allows the configured timing to expire, providing a changed PNP signal to the controller. The two outputs are individually adjustable.
Problem Solved
A timed material-presence signal bridges short feed gaps, helping the controller distinguish brief interruptions from sustained runout while the fiber head occupies the constrained sensing location.
Off delay
0–9,999 ms