MZT8-03VPS-KWX Sensors for T-slot cylinders – SICK Sensor

$ 53.24

SKU: SICK 1073405

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1073405
Magnetic Cylinder Sensor Model: MZT8-03VPS-KWX
OEM Spec Ref 

Features

Cylinder type T-slot
Cylinder types with adapter Profile cylinder

Tie rod cylinder

Round body cylinder

Dovetail groove cylinder

SMC rail CDQ2

SMC rail ECDQ2

Housing length 24 mm
Switching output PNP
Switching frequency 1,000 Hz
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP67 1)
  • 1) According to EN 60529 (IP 67 / IP 68).

Mechanics/electronics

Supply voltage 10 V DC … 26 V DC 1)
Power consumption 10 mA 2)
Voltage drop ≤ 2.2 V
Continuous current Ia ≤ 50 mA 1)
Ex area category 3G, 3D
Device labeling II 3G Ex nA op is IIC T4 Gc X, II 3D Ex tc IIIC T135 °C Dc X
Response sensitivity, typ. 2.8 mT
Overrun distance, typ. 3 mm
Hysteresis, typ. ≤ 0.5 mT
Reproducibility ≤ 0.1 mT 3)
Reverse polarity protection
Short-circuit protection
Power-up pulse protection
Ambient operating temperature –20 °C … +50 °C
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
EMC According to EN 60947-5-2
Connection type Cable, 3-wire, 2 m
Connection type Detail
Conductor cross-section 0.14 mm²
Cable diameter Ø 2.9 mm
Bending radius With fixed installation > 10 x cable diameter
For flexible use > 15 x cable diameter
Cable outlet Axial
Material
Housing Plastic, PA12
Cable PVC 4)
  • 1) Depend on ambient temperature. For details see operating instructions under „performance data of the sensor“.
  • 2) Without load.
  • 3) Ub and Ta constant.
  • 4) PVC-cable without UL-Certificate.

Safety-related parameters

MTTFD 2,289 years
DCavg 0 %
TM (mission time) 20 years