LUT9U-P130L Luminescence Sensors – SICK Sensor

$ 1,413.94

SKU: SICK 1045606

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1045606
Luminescence Sensor Model: LUT9U-P130L
OEM Spec Ref 

Features

Dimensions (W x H x D) 30.4 mm x 53 mm x 80 mm
Sensing distance 50 mm 1)
Housing design (light emission) Rectangular
Working range 20 mm … 70 mm
Light source LED, Ultraviolet light 2)
Wave length 375 nm
Light emission Long side
Light spot size 5 mm x 15 mm
Light spot direction Vertical
Receiving filters KV 418 (standard)
Receiving range 450 nm … 750 nm
Adjustment Teach-in button

IO-Link (optional)

Output function Light switching 3)
  • 1) From front edge of lens.
  • 2) Average service life: 100,000 h at TU = +25 °C.
  • 3) L/D switching via teach-in or IO-Link.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption < 100 mA 3)
Switching frequency 0.5 kHz 4)

2.5 kHz

6.5 kHz

Adjustable

Response time 1 ms 5)

200 µs

75 µs

Switching output PNP
Switching output (voltage) PNP: HIGH = VS– ≤ 2 V / LOW approx. 0 V
Switching mode Light switching
Analog output 0 mA … 13 mA
Output current Imax. 100 mA
Time delay Switch-off delay, 0 ms / 10 ms / 20 ms, adjustable (0 ms = default)
Connection type Male connector M12, 4-pin
Protection class II 6)
Circuit protection UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure rating IP67
Weight 400 g
Housing material Metal, zinc diecast
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) With light/dark ratio 1:1, without timer stage.
  • 5) Signal transit time with resistive load.
  • 6) Reference voltage DC 50 V.