KTM-MP31182P Contrast Sensors – SICK Sensor
$ 337.48
SKU: SICK 1070490
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1070490
Contrast Sensor Model: KTM-MP31182P
OEM Spec Ref
Features
Dimensions (W x H x D) | 12 mm x 31.5 mm x 21 mm |
Sensing distance | 12.5 mm |
Sensing distance tolerance | ± 3 mm |
Housing design (light emission) | Small |
Light source | LED, white 1) |
Light emission | Long side of housing |
Light spot size | Ø 2 mm (12.5 mm) |
Light spot direction | Round |
Receiving filters | None |
Adjustment | Teach-in button |
Teach-in mode | 2-point teach-in static/dynamic + proximity to mark
ET: Teach-in dynamic |
- 1) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 12 V DC … 24 V DC 1) |
Ripple | ≤ 5 Vpp 2) |
Current consumption | < 50 mA 3) |
Switching frequency | 15 kHz 4) |
Response time | 32 µs 5) |
Jitter | 15 µs |
Switching output | PNP |
Switching output (voltage) | PNP: HIGH = UV ≤ 2 V / LOW approx. 0 V |
Switching mode | Light/dark switching |
Output current Imax. | 50 mA 6) |
Input, dynamic teach-in (ET) | PNP: Teach: U = 10,8 V … < UV
PNP: Run: U < 2 V or open |
Retention time (ET) | 28 ms, non-volatile memory |
Time delay | None |
Connection type | Cable with M12 male connector, 4-pin, 0.2 m |
Protection class | III |
Circuit protection | UV connections, reverse polarity protected
Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP67 |
Weight | 20 g |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Indication | LED indicator green: power on
LED indicator, yellow: Status switching output Q |
- 1) Limit values: DC 12 V (–10 %) … DC 24 V (+20 %). Operation in short-circuit protected network max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) With light/dark ratio 1:1.
- 5) Signal transit time with resistive load.
- 6) Total current of all Outputs.