CM12-08EBP-KW1 Capacitive Proximity Sensors – SICK Sensor

$ 126.50

SKU: SICK 6051029

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6051029
Capacitive Proximity Sensor Model: CM12-08EBP-KW1
OEM Spec Ref 

Features

Housing Cylindrical thread design
Thread size M12 x 1
Diameter Ø 12 mm
Sensing range Sn 0.5 mm … 8 mm 1)

0.5 mm … 4 mm 2)

Safe sensing range Sa 5.76 mm
Installation type Non-flush / flush 3)
Switching frequency 15 Hz
Connection type Cable, 4-wire, 2 m 4)
Switching output PNP / NPN
Output function Programmable
Output characteristic Wire configurable 5)
Electrical wiring DC 4-wire
Adjustment Single teach-in button (Sensitivity)

Cable (Sensitivity)

Enclosure rating IP68 6) 7)
  • 1) For non-flush installation.
  • 2) For flush mounting.
  • 3) For flush mounting, Teach-in necessary.
  • 4) Do not bend below 0 °C.
  • 5) Automatic detection.
  • 6) According to EN 60529.
  • 7) 1.3 m water depth / 60 min.

Mechanics/electronics

Supply voltage 10 V DC … 36 V DC
Ripple ≤ 10 % 1)
Voltage drop ≤ 2.5 V DC 2)
Current consumption 12 mA 3)
Time delay before availability ≤ 120 ms
Hysteresis 3 % … 20 %
Reproducibility ≤ 5 % 4) 5)
EMC According to EN 60947-5-2 6)
Continuous current Ia ≤ 200 mA
Cable material PVC
Conductor size 0.14 mm²
Short-circuit protection
Reverse polarity protection
Power-up pulse protection
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature –20 °C … +85 °C
Ambient temperature, storage –40 °C … +85 °C
Housing material Plastic
Housing length 84.7 mm
Thread length 46.5 mm
Tightening torque, max. ≤ 1 Nm
Items supplied Mounting nut, PA12 plastic (2x)
UL File No. NRKH.E191603
  • 1) Of Ub.
  • 2) At Ia max.
  • 3) Without load.
  • 4) Of Sr.
  • 5) Ub and Ta constant.
  • 6) For non-flush installation min. 1 x Sn and sensor grounded.

 

Safety-related parameters

MTTFD 603 years
DCavg 0 %
TM (mission time) 20 years

Reduction factors

Note The values are reference values which may vary
Metal 1
Water 1
PVC Approx. 0.4
Oil Approx. 0.25
Glass 0.6
Ceramics 0.5
Alcohol 0.7
Wood 0.2 … 0.7