CM18-08BPP-TW0 Capacitive Proximity Sensors – SICK Sensor
$ 143.66
SKU: SICK 6026195
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6026195
Capacitive Proximity Sensor Model: CM18-08BPP-TW0
OEM Spec Ref
Features
Housing | Cylindrical thread design |
Thread size | M18 x 1 |
Diameter | Ø 18 mm |
Sensing range Sn | 3 mm … 8 mm |
Safe sensing range Sa | 5.76 mm |
Installation type | Flush |
Switching frequency | 30 Hz |
Connection type | Cable, 4-wire, 2 m 1) |
Switching output | PNP |
Output function | Complementary |
Electrical wiring | DC 4-wire |
Adjustment | Potentiometer, 270° (Sensitivity) |
Enclosure rating | IP67 2) |
- 1) Do not bend below 0 °C.
- 2) According to EN 60529.
Mechanics/electronics
Supply voltage | 10 V DC … 36 V DC |
Ripple | ≤ 10 % 1) |
Voltage drop | ≤ 2.5 V DC 2) |
Current consumption | 10 mA 3) |
Time delay before availability | ≤ 100 ms |
Hysteresis | 4 % … 20 % |
Reproducibility | ≤ 5 % 4) 5) |
Temperature drift (of Sr) | ± 10 % |
EMC | According to EN 60947-5-2 6) |
Continuous current Ia | ≤ 200 mA |
Cable material | PVC |
Conductor size | 0.34 mm² |
Short-circuit protection | ✔ |
Reverse polarity protection | ✔ |
Power-up pulse protection | ✔ |
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
Ambient operating temperature | –25 °C … +60 °C |
Housing material | PTFE coating, PTFE |
Housing length | 71.5 mm |
Thread length | 46.5 mm |
Tightening torque, max. | ≤ 2.6 Nm |
Items supplied | Mounting nut, PTFE plastic (2x)
Screwdriver for potentiometer adjustment (1 x) |
- 1) Of Ub.
- 2) At Ia max.
- 3) Without load.
- 4) Of Sr.
- 5) Ub and Ta constant.
- 6) In EMC critical applications, conducted interference levels may lie within the frequency range of the oscillator. This can cause changes to the output signal. (See operating instructions.).
Safety-related parameters
MTTFD | 897 years |
DCavg | 0 % |
TM (mission time) | 20 years |
Reduction factors
Note | The values are reference values which may vary |
Metal | 1 |
Water | 1 |
PVC | Approx. 0.4 |
Oil | Approx. 0.25 |
Glass | 0.6 |
Ceramics | 0.5 |
Alcohol | 0.7 |
Wood | 0.2 … 0.7 |