Contact Us:
sales@inosaki.com

STEP-PS/ 1AC/12DC/1.5/FL – 2868554 – Phoenix Contact Power Supply

$ 182.60

SKU Phoenix Contact 2868554 Category

Inosaki – Your Trusted Phoenix Contact Distributor
Inosaki proudly stands as one of the largest distributors of Phoenix Contact products, offering a comprehensive range of terminal blocks, interface modules, power supplies, and relays.

Our Best-Selling Terminal Blocks: Feed-Through, Fuse Modular, Spring Cage, Double Level, Multi-Level

Series Models: PT Series, ST Series, TB Series, UT Series, and UK Series, PTV Series, UKH Series, Micro Series.

Reliable Power Supply Solutions

Discover industry-leading Phoenix Contact power supplies, such as:

  • QUINT Power – Premium performance for critical systems
  • STEP Power – Compact design for space-saving applications
  • Trio Power – Rugged and reliable for industrial needs
  • UNO Power – Cost-effective and efficient

Get Your Phoenix Contact Catalog Today
Need detailed product information? Contact us at sales@inosaki.com to request your Phoenix Contact catalog.

Product Description

STEP POWER power supplies for distribution boards
The STEP POWER power supply range was developed especially for building automation. The low idling losses and high degree of efficiency ensure maximum energy efficiency. They allow flexible use and can be snapped onto the DIN rail or screwed onto an even surface.

Dimensions

Width 36 mm
Height 90 mm
Depth 43 mm
37 mm (Device depth (DIN rail mounting))
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 30 mm / 30 mm

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C … 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport) -40 °C … 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2

Input data

Nominal input voltage range 100 V AC … 240 V AC
Input voltage range 85 V AC … 264 V AC
95 V DC … 250 V DC
AC frequency range 45 Hz … 65 Hz
Frequency range DC 0 Hz
Current consumption 0.33 A (120 V AC)
0.18 A (230 V AC)
Nominal power consumption 37.9 VA
Inrush current < 15 A (typical)
Mains buffering time typ. 15 ms (120 V AC)
typ. 70 ms (230 V AC)
Input fuse 1.25 A (slow-blow, internal)
Recommended breaker for input protection 6 A … 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.57
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data

Nominal output voltage 12 V DC ±1 %
Nominal output current (IN) 1.5 A (-25 °C … 55 °C)
1.65 A (-25°C … 40°C permanent )
Output current Imax 2.6 A
Derating 55 °C … 70 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance ≤ 25 V DC
Protection against overvoltage at the output (OVP) < 25 V DC
Control deviation < 1 % (change in load, static 10 % … 90 %)
< 2 % (change in load, dynamic 10 % … 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 75 mVPP (20 MHz)
Output power 18 W
Typical response time < 0.5 s
Peak switching voltages nominal load < 10 mVPP (20 MHz)
Maximum power dissipation in no-load condition < 0.4 W
Power loss nominal load max. < 3.2 W

General

Article Number 2868554
Net weight 0.07 kg
Operating voltage display Green LED
Efficiency > 84 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500) > 1800000 h (40 °C)
Insulation voltage input/output 4 kV AC (type test)
3.75 kV AC (routine test)
Degree of protection IP20
Protection class II (in closed control cabinet)
Housing material Polycarbonate
Foot latch material POM (Polyoxymethylene)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: 0 mm horizontally, 30 mm vertically

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 6.5 mm
Screw thread M3

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 6.5 mm
Screw thread M3

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Budgetary standard IEC 60335-1
Standard – Safety of transformers EN 61558-2-16
Standard – Electrical safety IEC 62368-1 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard – Safe isolation DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Limitation of mains harmonic currents EN 61000-3-2
Standard – Approval for medical use IEC 60601-1, 2 x MOOP
Rail applications EN 50121-4

Conformance/approvals

UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
NEC Class 2 as per UL 1310
CSA CSA-C22.2 No. 107.1-01
Shipbuilding approval DNV GL (EMC B) ABS, NK

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 8 kV (Test Level 4)
Discharge in air 8 kV (Test Level 3)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz … 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 4 kV (Test Level 4 – asymmetrical)
Output 2 kV (Test Level 3 – asymmetrical)
Comments Criterion A
Surge voltage load (surge) EN 61000-4-5
Input 2 kV (Test Level 3 – symmetrical)
4 kV (Test Level 4 – asymmetrical)
Output 0.5 kV (Test Level 1 – symmetrical)
1 kV (Test Level 2 – asymmetrical)
Comments Criterion A
Conducted interference EN 61000-4-6
Frequency range 10 kHz … 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Voltage dips EN 61000-4-11
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

Additional information

Related Products

camera-gige-ueye-le-boardlevel-5482-1
SIEMENS_SIMATIC-S7-400_SM431_Analog Input Modules
SCHNEIDER_TeSys Deca Switching Capacitor Contactor-30KVAR-220 V-50-60Hz-1NO+2NC
M20-1
ER-VAB065
SCHNEIDER_TeSys Deca Contactor,3 Pole (3NO),AC-3,=440V,115A,24VAC,Screw Terminal
Select your currency