Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.
Features
• Pressure status can be checked at a glance from the digital display and bar display.
• Measurement pressure prevents incorrect outputs due to momentary pressure changes. (*)
• Perform automatic teaching simply by teaching pressure values for good and bad products.
• Compact models at just 28 × 28 × 29 mm.
* Only in hysteresis mode.
Lineup
Sensors
Pressure range | ON/OFF output | Linear output | Model | ||
---|---|---|---|---|---|
NPN output | PNP output | ||||
Positive pressure | 0 to 100 kPa | Open collector (two independent outputs) |
1 to 5 V | E8F2-A01C | E8F2-A01B |
0 to 1 MPa | E8F2-B10C | E8F2-B10B | |||
Negative pressure | 0 to -101 kPa | E8F2-AN0C | E8F2-AN0B |
Accessories (Order Separately)
Appearance | Name | Model | Remarks |
---|---|---|---|
Mounting Bracket | E89-F3 | Provided with the E8F2. | |
Panel-mounting Bracket | E89-F4 | Spacer provided. |
Specifications
Sensor
Model | NPN output | E8F2-A01C | E8F2-B10C | E8F2-AN0C |
---|---|---|---|---|
PNP output | E8F2-A01B | E8F2-B10B | E8F2-AN0B | |
Power supply voltage | 12 to 24 VDC±10% with a ripple (p-p) of 10% max. | |||
Current consumption | 70 mA max. * 1 | |||
Pressure type | Gauge pressure | |||
Rated pressure range | 0 to 100 kPa | 0 to 1 MPa | 0 to -101 kPa | |
Pressure setting range | 0 to 100 kPa | 0 to 1 MPa | 0 to -101 kPa | |
Withstand pressure | 400 kPa | 1.5 MPa | 400 kPa | |
Applicable fluid | Non-corrosive gas and non-flammable gas | |||
Operating mode | Hysteresis mode, window mode, and automatic teaching mode | |||
Repeat accuracy (ON/OFF output) |
±1%FS max. | |||
Linearity (linear output) | ±1%FS max. | |||
Response time (ON/OFF output) |
5 ms max. | |||
Linear output | 1 to 5 V ±5% F.S. with an output impedance of 1 kΩ and a permissible resistive load of 500 kΩ. | |||
ON/OFF outputs | NO or NC open collector (depending on whether the output configuration is NPN or PNP) | |||
ON/OFF outputs |
Load current | 30 mA max. | ||
Output applied voltage | 30 VDC max. | |||
Residual voltage | NPN open collector output: 1 V max. with 30 mA load current PNP open collector output: 2 V max. with 30 mA load current |
|||
Display * 2 | 3.5-digit red LED Green LED bar indicator The orange LED is lit for two independent outputs with output transistor turned ON. Green unit indicator |
|||
Display accuracy | ±3%FS±1 digit max. | |||
Protection circuits | Reverse polarity protection, load short-circuit protection | |||
Ambient temperature range | Operating: 0 to 55°C Storage: – 10 to 60°C (with no icing) |
|||
Ambient humidity range | Operating/Storage: 35% to 85% (with no condensation) | |||
Temperature influence | ±3%FS max. | |||
Voltage influence | ±1.5%FS max. | |||
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC at 1 min | |||
Vibration resistance | Destruction: 10 to 500 Hz, 1.0-mm double amplitude or 150 m/s2, three times each for 11 min in the X, Y, and Z directions | |||
Shock resistance | Destruction: 300 m/s2 3 times each in the X, Y, and Z directions | |||
Degree of protection | IP50 (IEC) | |||
Pressure port | R (PT) 1/8 taper screw and M5 female screw | |||
Connection method | Pre-wired (standard length: 2 m) | |||
Cable | Approved by UL | |||
Weight (packed state) | Approx. 110 g | |||
Material | Pressure port | Aluminum die-cast | ||
Case | Heat-resistive ABS | |||
Accessories | Mounting Bracket, Instruction manual |
*1. The current consumption is approximately 43 mA in energy-saving mode.
*2. Display Example of Digital Indicator
Model | Setting unit | |
---|---|---|
kPa | ||
Applied pressure | Digital display | |
E8F2-A01C | 100 | |
E8F2-B10C | 1000 | |
E8F2-AN0C | -101 |
Its position will not change unless the setting unit is changed.