Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.

Features

SUS316L Body, IP69K Protection, Resistant to High Temperatures and Detergents

Improved resistance to detergents and rusting

Applicable to 120°C (with DC 3-wire connection)
(Heat resistance verified to 1,000 hours.)

Resists typical detergents and disinfectants used in the food industry

Water-resistant under high-temperature, high-pressure cleaning based on DIN 40050-9.
(Pressure: 8,000 to 10,000 kPa, Water temperature: 80°C, For 30 s at all angles)

Lineup

Sensors

Pre-wired Models

Appearance Sensing distance Output configuration Operation mode: NO Operation mode: NC
M12 3 mm DC 2-wire (polarity) E2EH-X3D1 2M E2EH-X3D2 2M
DC 2-wire (no polarity) * E2EH-X3D1-T 2M
DC 3-wire (PNP) E2EH-X3B1 2M E2EH-X3B2 2M
DC 3-wire (NPN) E2EH-X3C1 2M E2EH-X3C2 2M
M18 7 mm DC 2-wire (polarity) E2EH-X7D1 2M E2EH-X7D2 2M
DC 2-wire (no polarity) * E2EH-X7D1-T 2M
DC 3-wire (PNP) E2EH-X7B1 2M E2EH-X7B2 2M
DC 3-wire (NPN) E2EH-X7C1 2M E2EH-X7C2 2M
M30 12 mm DC 2-wire (polarity) E2EH-X12D1 2M E2EH-X12D2 2M
DC 2-wire (no polarity) * E2EH-X12D1-T 2M
DC 3-wire (PNP) E2EH-X12B1 2M E2EH-X12B2 2M
DC 3-wire (NPN) E2EH-X12C1 2M E2EH-X12C2 2M

 

Connector Models (M12)

Appearance Sensing distance Output configuration Operation mode: NO Operation mode: NC
M12 3 mm DC 2-wire (polarity) E2EH-X3D1-M1G E2EH-X3D2-M1G
DC 3-wire (PNP) E2EH-X3B1-M1 E2EH-X3B2-M1
DC 3-wire (NPN) E2EH-X3C1-M1 E2EH-X3C2-M1
M18 7 mm DC 2-wire (polarity) E2EH-X7D1-M1G E2EH-X7D2-M1G
DC 3-wire (PNP) E2EH-X7B1-M1 E2EH-X7B2-M1
DC 3-wire (NPN) E2EH-X7C1-M1 E2EH-X7C2-M1
M30 12 mm DC 2-wire (polarity) E2EH-X12D1-M1G E2EH-X12D2-M1G
DC 3-wire (PNP) E2EH-X12B1-M1 E2EH-X12B2-M1
DC 3-wire (NPN) E2EH-X12C1-M1 E2EH-X12C2-M1
* When using a no-polarity model, there is no need to be concerned about whether to connect to the positive or negative side of the power supply. The load can be connected to either the +V side or 0 V side.

 

Accessories (Order Separately)

Sensor I/O Connectors (M12, Sockets on One Cable End)

(Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)

Appearance Cable length Sensor I/O Connector model Applicable Proximity Sensors
Straight
2 m XS2F-E421-D80-E E2EH-X[]D[]-M1G
E2EH-X[]B[]-M1
E2EH-X[]C[]-M1
5 m XS2F-E421-G80-E
L-shape
2 m XS2F-E422-D80-E
5 m XS2F-E422-G80-E
Note: The above Connectors conform to DIN40050-9 standard, provide IP69K protection, have a maximum operating temperature of 105°C, and use SUS316L stainless steel.

 

Specifications

E2EH-X[]D[] DC 2-Wire Models

Size
Shielded
Model
M12 M18 M30
Shielded
E2EH-X3D[] E2EH-X7D[] E2EH-X12D[]
Sensing distance 3 mm 7 mm 12 mm
Set distance *1 0 to 2.4 mm 0 to 5.6 mm 0 to 9.6 mm
Differential travel 15% max. of sensing distance
Response frequency *2 500 Hz 300 Hz 100 Hz
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.)
Leakage current 0.8 mA max.
Power supply voltage
(operating voltage range)
12 to 24 VDC, ripple (p-p): 10% max.
(10 to 32 VDC, however, 24 VDC max. at temperatures over 100 ° C)
Control Output Load Current 3 to 100 mA (however, 3 to 50 mA at 100 to 110 ° C)
Residual voltage *3 Polarity Models: 3 V max.
No polarity Models: E2EH-X[]D[]-T : (5 V max. *3 (Load current: 100 mA, Cable length 2 m)
Indicators D1 Models: Operation indicator (red), Setting indicator (yellow)
D2 Models: Operation indicator (yellow)
Operation mode (with
sensing object approaching)
D1 Models: NO
D2 Models: NC
Refer to Datasheet.
Protection circuits Surge suppressor, Load short-circuit protection
Ambient
temperature range
Operating: 0 to 100 ° C (0 to 110 ° C 1,000 h) *4
Storage: – 25 to 70 ° (with no icing or condensation)
Ambient humidity range 35% to 95%
Temperature influence ± 10% max. of sensing distance at 23 ° C in the temperature range of 0 to 70 ° C.

± 15% max. of sensing distance at 23 ° C in the temperature range of 70 to 100 ° C.

– 15% to +20% of sensing distance at 23 ° C in the temperature range of 100 to 110 ° C.

Voltage influence ± 10% max. of sensing distance at rated voltage in the 15% rated voltage range.
Insulation resistance 50 M Ω min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions
Degree of protection IEC IP67, DIN 40050-9 IP69K *5
Connection method Pre-wired Models (Standard cable length 2 m), Connector Models
Weight
(packed
state)
Pre-wired
Models
Approx. 80 g Approx. 145 g Approx. 220 g
Connector
Models
Approx. 30 g Approx. 55 g Approx. 125 g
Materials Case,
clamping
nut
Stainless steel (SUS316L)
Sensing
surface
PBT
Cable Heat-resistant PVC cable (Pre-wired model)
Accessories Instruction manual
Standard sensing object Iron, 12 × 12 × 1 mm Iron 21 × 21 × 1 mm Iron 36 × 36 × 1 mm

*1. Use the yellow indicator on D1 Models as a guide.

*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each E2EH-X[]D[] DC 2-Wire Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to Data Sheet.)
*4. Operation with power supplied for 1,000 h has been verified at 110°C. Do not bend the cable repeatedly at 100°C or higher.
*5. IP69K Degree of Protection Specification IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050, Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane.

E2EH-X[]C[]/B[] DC 3-Wire Models

Size
Shielded
Model
M12 M18 M30
Shielded
E2EH-X3C[]/B[] E2EH-X7C[]/B[] E2EH-X12C[]/B[]
Sensing distance 3 mm±10% 7 mm±10% 12 mm±10%
Set distance *1 0 to 2.4 mm 0 to 5.6 mm 0 to 9.6 mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron 21 × 21 × 1 mm Iron 36 × 36 × 1 mm
Response frequency *2 500 Hz 300 Hz 100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC, ripple (p-p): 10% max.
(10 to 32 VDC, however, 24 VDC max. at temperatures over 100 ° C)
Current consumption 10 mA max.
Control
output
Load
current
100 mA max. (however, 50 mA max. at 100 to 120 ° C)
Residual
voltage
2 V max. (Load current: 100 mA, Cable length 2 m)
Indicators Operation indicator (yellow)
Operating mode
(with sensing object
approaching)
C1 Models: NO
C2 Models: NC
B1 Models: NO
B2 Models: NC
Refer to Datasheet.
Protection circuits Power supply reverse polarity protection, Surge suppressor, Load short-circuit protection, Reversed output polarity protection
Ambient
temperature range
Operating: 0 to 100 ° C (0 to 120 ° C 1,000 h) *2
Storage: – 25 to 70 ° C (with no icing or condensation)
Ambient humidity range 35% to 95%
Temperature influence ± 10% max. of sensing distance at 23 ° C in the temperature range of 0 to 70 ° C.
± 15% max. of sensing distance at 23 ° C in the temperature range of 70 to 100 ° C.
– 15% to 20% of sensing distance at 23 ° C in the temperature range of 100 to 120 ° C.
Voltage influence 10% max. of sensing distance at rated voltage in the 15% rated voltage range.
Insulation resistance 50 M Ω min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions
Degree of protection IEC IP67, DIN 40050-9 IP69K
Connection method Pre-wired Models (Standard cable length 2 m), Connector Models
Weight
(packed
state)
Pre-wired
Models
Approx. 80 g Approx. 145 g Approx. 220 g
Connector
Models
Approx. 30 g Approx. 55 g Approx. 125 g
Materials Case,
clamping
nut
Stainless steel (SUS316L)
Sensing
surface
PBT
Cable Heat-resistant PVC cable (Pre-wired Model)
Accessories Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Operation with power supplied for 1,000 h has been verified at 120°C. Do not bend the cable repeatedly at 100°C or higher.

 

Resistance to Detergents, Disinfectants, and Chemicals

  • Performance is assured for typical detergents and disinfectants, but performance may not be maintained for some detergents and disinfectants. Refer to the following table when using these agents.
  • The E2EH passed testing for resistance to detergents and disinfectants performed using the items in the following table. Refer to this table when considering use of detergents and disinfectants.

 

Category Product name Concentration Temperature Time
Chemical Sodium hydroxide (NaOH) 1.5% 70 ° C 240h
Potassium hydroxide (KOH) 1.5% 70 ° C 240h
Phosphoric acid (H3PO4) 2.5% 70 ° C 240h
Sodium hypochlorite (NaClO) 0.3% 25 ° C 240h
Hydrogen peroxide (H2O2) 6.5% 25 ° C 240h
Alkaline foam detergent P3-topax-66s (Manufactured by Ecolab) 3.0% 70 ° C 240h
Acidic foam detergent P3-topax-56 (Manufactured by Ecolab) 5.0% 70 ° C 240h
Disinfectant P3-oxonia active 90 (Manufactured by Ecolab) 1.0% 25 ° C 240h

 

Test Conditions

After the test is completed, check that no problems exist with the following product characteristics.
(1) Appearance (no damage that will affect the product characteristics)
(2) Operation Check (ON/OFF)
(3) Insulation resistance: 50 MΩ min. (at 500 VDC)
(4) Dielectric strength (1,000 VAC for 1 minute)
(5) Water resistance (IP67)

Additional information

Related Products

IDS_Camera_uEye+_LE_VU_AF_BoardLevel_S_Mount_1
$ 914.76 - $ 921.80
BC15-LDT-C
M5
M10
Festo_Industrial Shock AbsorbersDYSR-8-8-Y5_1138641
SMC_Fan Type Ionizer Without Flow Rate Adjustment Function_IZF10-P_2
Select your currency